LEADPOWER WAN-H100V012T AC to DC LED Power Supply or LED Driver Owner’s Manual
- June 12, 2024
- LEADPOWER
Table of Contents
WAN-H100V012T AC to DC LED Power Supply or LED Driver
Owner’s Manual
Model WAN-H100V012T
Product Features
- Input voltage range 176~264Vac;
- High efficiency, low temperature rise, high reliability;
- Built-in EMI filter, lower ripple & low noise;
- Protections: over current protection, over load protection, short circuit protection.
Electric Characteristic
1 | Input |
---|---|
No. | Item |
1.1 | Rated Input Voltage |
1.2 | Input Voltage Range |
1.3 | Rated Frequency |
1.4 | Frequency Range |
1.5 | Max. Input Current |
1.6 | Inrush Current |
2 | Output |
No. | Item |
2.1 | Rated output voltage |
2.2 | Rated output current |
2.3 | Max Output power |
2.4 | Efficiency |
2.5 | Line regulation |
2.6 | Load regulation |
2.7 | Voltage tolerance |
2.8 | Ripple & Noise |
20MHz, connected a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor
in parallel to the output terminals.
2.9| Dynamic Response Overshoot|
≤5
| %| 5%~50%~25%, 50%~75%~50 load dynamics, half-wave period is 4mS, current
change slope is 0.1A/uS
2.10| Dynamic Response Recovery Time| 200| us
2.11| Turn-on Delay Time| ≤3| s| 200~240Vac input, rated load
2.12| Output Voltage Rise Time| ≤70| ms| 200~240Vac input, rated load,25℃
2.13| Turn-on/off Overshoot| ≤±10%| |
3| Protection
No.| Item| Technical Requirements| Unit| Note
3.1| Over Current Protection| 9.5~12| A| Hiccup model, recovers automatically
after fault condition is removed
3.2| Short Circuit Protection| Long time short-circuit protection without
damage, recovers automatically after fault condition is removed.
Environment
No. | Item | Specs | Unit | Note |
---|---|---|---|---|
1 | Working temperature range | -30~ +70(Typ. 25) | ℃ | Refer to derating curving |
2 | Max case temperature | 90 | ℃ | Tc |
3 | Storage temperature range | -40~ +80(Typ. 25) | ℃ | |
4 | Relative humidity | 20~95 | % | No condensing |
5 | Altitude | 0~5000 | m | |
6 | Protection Rating | IP67 | The power supply shall not be immersed in water |
for more than 0.5 hours (less than 1 meter in depth); It shall not be buried
underground for use.
7| Cooling method| Ventilation cooling| |
Reliability Requirement
MTBF≥100Khours.
Test condition: 25℃, rated input, rated load, MIL-HDBK-217F Notice 2
Safety standards
No. | Item | Testing Condition | Note |
---|---|---|---|
4.1. | Dielectric Strength (Hi-Pot) | I/P-O/P | 3750Vac, 60S, current≤10mA |
arcing,no breakdown
I/P-FG| 1750Vac, 60S, current≤10mA
O/P-FG| 500Vac, 60S, current≤10mA
4.2| Insulation Resistance| I/P-O/P| ≥10MΩ@ 500Vdc| 90% RH, 1 atm
I/P-FG| ≥10MΩ@ 500Vdc
O/P-FG| ≥10MΩ@ 500Vdc
4.3| Leakage Current| <0.75mA| 240Vac/60Hz
4.4| Safety Standard| GB19510.1,.14/EN61347-1,-2-13/EN62384/UL8750/IP67
4.5| Electromagnetic Interference| EN61547; EN61000-4-2,3,4,5,6,8,11; (surge
immunity Line-Earth 4KV, Line-Line 2KV)
Mechanic Specification
5.1 Terminals (Unit: mm)
No. | Item | Parameters/mm | Note |
---|---|---|---|
5.1.1 | Overall Dimension | 166(L)51 (W)28.5(H) | |
5.1.2 | Three core input cable | Length:300mm | Brown(L) Blue(N) Yellow-Green (G) |
5.1.3 | Two-core output cable | Length:200mm | Brown(V+) Blue(V-) |
5.2 Dimension (Unit: mm)
Note: L1=300±5mm;L2=200±5mm;L3=30±2mm;L4=30±2mm;L5=5±1mm
Derating Curve
In order to ensure that the product can achieve the expected design service life, please configure the AC supply voltage and load of the power supply according to the derating requirements of the following curve. When the ambient temperature rises to a certain value, the output power also needs to be derated.
References