digicom 8D5895MDM 4G Industrial Pro Modem User Guide
- June 4, 2024
- digicom
Table of Contents
- digicom 8D5895MDM 4G Industrial Pro Modem
- PREFACE
- ENVIRONMENTAL CONDITIONS
- CLEANING INFORMATION
- SIMPLIFIED UE DECLARATION OF CONFORMITY
- ASSISTANCE AND CONTACTS
- SAFETY WARNINGS
- INFORMATION TO USERS
- INTRODUCTION
- CARATTERISTICHE TECNICHE
- PACKAGE CONTENT
- INSTALLATION
- FACTORY DEFAULT
- THE SIM CARD
- CONNECT THE ANTENNA
- RS232 CONNECTOR
- SCREW TERMINAL BLOCK FOR RS485
- SCREW TERMINAL BLOCK FOR POWER SUPPLY
- LED INDICATORS
- Digicom S.r.l.
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
digicom 8D5895MDM 4G Industrial Pro Modem
All rights reserved; no part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, otherwise, without the prior written permission of Digicom. The contents of this booklet may be modified without notice. Every possible care has been taken in testing and putting together all the documentation contained in this booklet, however, Digicom can not take any responsibility brought by the use of this booklet.
PREFACE
In order to guarantee your safety and correct functioning, be sure to follow these safety warnings. The whole set (with cables included) must be installed in a place lacking of or distant from:
- Dust, humidity, high temperatures and direct exposure to sunlight.
- Heat irradiating objects, which may damage your device or cause any other problem.
- Objects producing a high electromagnetic field (Hi-Fi speakers, etc.).
- Corrosive liquids or chemical substances.
ENVIRONMENTAL CONDITIONS
- Environment temperature: from -20 °C to +55 °C
- Relative humidity: from 20 to 80 % n.c.
- Any sudden change in temperature and humidity must be avoided.
CLEANING INFORMATION
- Use a soft dry cloth and avoid any solvents or abrasive materials.
SHOCKS OR VIBRATIONS
- Caution against shocks or vibrations.
SIMPLIFIED UE DECLARATION OF CONFORMITY
- The manufacturer, Digicom S.r.l., declares that this radio equipment 4G INDUSTRIAL PRO and 2G INDUSTRIAL PRO are compliant with Directive 2014/53/UE.
- The complete text of UE Declaration of Conformity is available at the following internet address: www.digicom.it
ASSISTANCE AND CONTACTS
- After reading the instructions carefully if you are unable to solve the problem, contact Digicom technical support.
- E-mail: support@digicom.it
SAFETY WARNINGS
Read these instructions and norms carefully before powering the device. Violation of such norms may be illegal and cause hazard situations. For any of the described situations please refer to the specific instructions and norms. The device is a low power radio transmitter and receiver. When it is ON, it sends and receives radio frequency (RF) signals. The device produces magnetic fields. Do not place it next to magnetic supports such as floppy disks, tapes, etc. Operating your device close to other electrical and electronic equipment – such as a television, phone, radio or a personal computer may cause interferences.
INTERFERENCES: The device, like all other wireless devices, is subject to interferences that may reduce its performance.
ROAD SAFETY: Do not use your device while driving. In case of use on cars, you must check that the electronic equipment is shielded against RF signals. Do not place the device in the air bag deployment area.
AIRCRAFT SAFETY: Switch off your device when on board aircraft by disconnecting the power supply and deactivating the internal backup battery. Using GSM devices on aircraft is illegal.
HOSPITAL SAFETY
- Do not use the device near health equipment, especially pacemakers and hearing aids, in order to avoid potential interferences.
- Take care when utilizing the device inside hospitals and medical centers, which make use of equipment that could be sensitive to external RF signals. Switch it off when use is expressly forbidden.
EXPLOSIVE MATERIALS: Do not use the device in refueling points, near fuel or chemicals. Do not use the device where blasting is in progress. Observe restrictions and follow any specific regulations or instructions.
INSTRUCTIONS FOR USE: Do not use this device in direct contact with the human body and keep a minimum distance of 20 cm from it and from the antenna. Use approved accessories only. Consult the user’s manual of eventual other equipment connected to this device. Do not connect incompatible products.
INFORMATION TO USERS
according to Art. 26 “Information to Users” – Legislative Decree 14 March 2014, n. 49 “Actuation of the Directive 2012/19/UE on the waste of electrical and electronic devices (RAEE).” The symbol of a crossed waste container marked on the apparatus or on its package indicates that at the end of its useful life the product must be collected separately from other waste materials. The user must therefore take the apparatus which has reached the end of its useful life to appropriate separate collection centres for electronic and electro- technical waste materials, or deliver it back to the reseller when purchasing a new apparatus of an equivalent type for a domestic unit, giving one piece in for one piece out, according to Art. 11, paragraph 3 of the above mentioned Legislative Decree.
Furthermore, as per Art.11, paragraph 3 of the above-mentioned Legislative Decree it is possible, in the sale point, the free insertion of recyclable materials into appropriate receptacle, without any purchasing obligation for the very small size RAEE, coming from domestic units. Suitable separate waste collection for then sending the cast-off apparatus for recycling, treatment and environmentally friendly disposal, contributes towards preventing any possible negative effects on the environment and on health and encourages recycling of the materials the apparatus is made up of. Unauthorised disposal of the product by the user will lead to payment of the administrative sanctions in force in the country where it is put on the market.
INTRODUCTION
Thanks for purchasing a Digicom product!
2G INDUSTRIAL PRO is a GSM/GPRS Quad Band modem (850/900/1800/1900 Mhz), 4G INDUSTRIAL PRO is a 4G/LTE modem: 3/7/20 bands (1800/2600/800 MHz), both with RS232 serial interface perfect for DATA connections and SMS applications and with RS485 serial interface for DATA connections.
CARATTERISTICHE TECNICHE
- 2G INDUSTRIAL PRO
- Module GSM: 2G/GSM-GPRS Quad-Band
- 850/900/1800/1900MHz
- GPRS class 10
- GSM speed up to 9600 bps
- Power
- GSM/GPRS Power Class 4 (33 dBm) for bands GSM/E-GSM
- Power Class 1 (30 dBm) for bands DCS/PCS
- 4G INDUSTRIAL PRO
- Module 4G/LTE-FDD
- 4G/LTE bands 3/7/20 (1800/2600/800 MHz)
- DCS band 3 (1800 MHz)
- E-GSM band 8 (900 MHz)
- Cat 1
- Power
- 4G/LTE Power Class 3 (23 dBm)
- GSM/GPRS (GSMK) Power Class 4 (33 dBm) for band E-GSM Power Class 1 (30 dBm) for band DCS
- EDGE (8-PSK) Power Class E2 (27 dBm) for band E-GSM Power Class E2 (26 dBm) for band DCS
- Bluetooth Low Energy (BLE) radio module
- Working frequencies: from 2.402 to 2.480 GHz
- Maximum transmission power: +4 dBm
- Built-in Full TCP/IP Stack
- Extended Power range from 9 to 32 Vdc
- RS232 serial interface on DB9 Female for AT commands
- RS232 serial interface on DB9 Female for DATA connections
- RS485 serial interface on screw terminal block for DATA connections
- DIN-rail Mounting Housing
- SMA connector for Antenna
- Led indicators
- Dimensions: 115 x 99 x 22,5 mm
- CE Mark and Rohs compliant
PACKAGE CONTENT
- 1 2G INDUSTRIAL PRO – code 8D5895AMDM or n.1 4G INDUSTRIAL PRO – code 8D5895MDM
- 1 Switching power supply (IN: 100-240 Vac / 50-60Hz / 0,5A – OUT 12 Vdc / 1A) (code 7101000434)
- 1 2G Antenna with 3 meters cable (code 7165000134) or 4G Antenna with 3 meters cable (code 7165000934)
- 1 Screw terminal block at 4pin for power supply (code 2D0889)
- 3 Screw terminal block at 3pin (code 7205013134)
- 1 Quick Guide (code 750600053400)
INSTALLATION
- Insert the SIM card into 2G Industrial PRO or 4G Industrial PRO.
- Connect the antenna.
- Connect the serial port RS232 or RS485 of 2G INDUSTRIAL PRO or 4G INDUSTRIAL PRO to your device.
- Turn on 2G INDUSTRIAL PRO or 4G INDUSTRIAL PRO.
- Check the GSM network status and GSM level through the Led indicators.
For further detail of the above operations, please read the following paragraphs
FACTORY DEFAULT
- RS232: active for configuration and DATA connections.
- ATS0=1 AT+IPR=9600 AT+ICF=3,1 AT&D0 AT+IFC=0,0
- RS485: deactive.
- To activate, send the following AT command via RS232
- AT+DG485=1,speed,data,parity,stop (e.g. AT+DG485=1,9600,8,N,1)
THE SIM CARD
2G INDUSTRIAL PRO or 4G INDUSTRIAL PRO can works with SIM Card (Mini-SIM 2FF size) of any GSM operator.
-
Turn the 2G INDUSTRIAL PRO or 4G INDUSTRIAL PRO off.
-
To remove the SIM card, push it in the device, then release it.
Attention: check with your GSM provider if your SIM is enabled for SMS and DATA traffic, if not ask him for this service, he will give you another number for data calls.
CONNECT THE ANTENNA
-
Turn the 2G INDUSTRIAL PRO or 4G INDUSTRIAL PRO off.
-
Place the antenna and the device, and check if there is a good quality signal through the led indicators and AT+CSQ command for 2G model or AT+CESQ command for 4G model.
Attention: apply the magnetic base of the antenna only on metal zone, without connection to earth. Please use eventually the metal support, find in the package, fixed it to the wall.
RS232 CONNECTOR
SCREW TERMINAL BLOCK FOR RS485
Connect your RS485 devices to pins 485- , 485+, and GND (pin 8, 9 and 6). To enable the termination resistance integrated into 2G INDUSTRIAL PRO or 4G INDUSTRIAL PRO, connect together the pins: 120ohm and 485.
SCREW TERMINAL BLOCK FOR POWER SUPPLY
2G INDUSTRIAL PRO o 4G INDUSTRIAL PRO
- +: from 9 to 32 Vdc
- – : GND
ATTENTION
- respect the positive and negative pin. The power supply voltage must not exceed the indicated maximum value as this may cause a damage of the product.
- to fully meet the essential requirements of Electromagnetic Compatibility (EMC), connect the DIN rail to electrical system Ground.
LED INDICATORS
Through two led indicators you can control the status of 2G INDUSTRIAL PRO or 4G INDUSTRIAL PRO:
Digicom S.r.l.
- ADDREES: ITALY Viale Luigi Cadorna 9520025 Legnano -MI-
- Tel: +39.0331.702611
- www.digicom.it
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>