Product Information

The Meter Assembly VM-1 / AM-1 / MPM-3 is a set of meters designed for use with the CHG-120 charger. It includes an ammeter (AM-1), a voltmeter (VM-1), or both (MPM-3) that can be installed to monitor the charging process. The meters come with the necessary cables and connectors for easy installation.

Optional Meters

Item Part Number Description
Ammeter AM-1 0-10 A ammeter with a 3 ft (.914 m) cable for connection to the

charger at JP3. Mounts into a BB-55 battery box only.
Voltmeter| VM-1| 0-50 V voltmeter with 3 ft (.914 m) positive and negative leads
for connection to the charger output circuit. Mounts into a BB-55
battery box only.
Ammeter and Voltmeter Assembly| MPM-3| An AM-1 and VM-1 are attached to a mounting bracket. Mounts onto an
MPS-24A or MPS-400 power supply.

Product Usage Instructions

Installing an AM-1

  1. Mount the AM-1 ammeter into a BB-55 battery box.
  2. Connect the 3 ft (.914 m) cable of the AM-1 to the charger at JP3.
  3. Connect the positive and negative leads of the AM-1 to the battery terminals.

Installing a VM-1

  1. Mount the VM-1 voltmeter into a BB-55 battery box.
  2. Connect the positive and negative leads of the VM-1 to the charger output circuit.

Installing an MPM-3

Note:
The MPM-3 must be installed with the supplied mounting hardware.

  1. Remove any original mounting screws from either power supply’s PC board at the MPM-3 installation site.
  2. Mount the MPM-3 onto an MPS-24A or MPS-400 power supply using the provided mounting bracket.

Introduction

An ammeter (AM-1), or voltmeter (VM-1), or both (MPM-3) can be installed for use with the CHG-120 charger. Refer to Table 1 for descriptions of optional connectors on the charger. If mounting an AM-1 or a VM-1, mount the meter to a BB-55 as shown in Figure 2. If mounting an MPM-3, mount to a power supply (Figure 3) installed in a CAB-3. Table 1 contains descriptions and part numbers for these optional meters.

PART LIST

ITEM

| PART NUMBER|

DESCRIPTION

---|---|---

Ammeter

|

AM-1

| 0-10 A ammeter with a 3 ft ( .914 m) cable for connection to the charger at JP3. Mounts into a BB-55 battery box only.

Voltmeter

|

VM-1

| 0-50 V voltmeter with 3 ft ( .914 m) positive and negative leads for connection to the charger output circuit. Mounts into a BB-55 battery box only.
Ammeter and Voltmeter Assembly|

MPM-3

| An AM-1 and VM-1 attached to a mounting bracket. Mounts onto an MPS-24A or MPS-400 power supply.

Installation

Installing an AM-1
Perform the following steps to install an AM-1:

  • Cut jumper JP9 on the charger (refer to Figure 1).
  • Connect the AM-1 harness to JP3 on the charger (refer to Figure 1). Be sure to observe proper polarity.
  • Mount the AM-1 into a mounting slot on the front of the BB-55 (refer to Figure 2).NOTIFIER-VM-1,-AM-1,-MPM-3-Meter-fig- \(2\)

Installing a VM-1
A VM-1 can be connected across a charger output circuit. For example, to install a VM-1 to measure voltage from charger output circuit 2, perform the following steps:

  • Connect the positive lead to TB2 Out 2 (+) (refer to Figure 1).
  • Connect the negative lead to TB2 Out 2 (–) (refer to Figure 1).
  • Mount the VM-1 into a mounting slot on the front of the BB-55 battery box.NOTIFIER-VM-1,-AM-1,-MPM-3-Meter-fig- \(3\)

Installing an MPM-3
Perform the following steps to install an MPM-3:

  • Connect the AM-1 (refer to Figure 1).
  • Connect the VM-1 (refer to Figure 1).
  • Mount the MPM-3 onto an MPS-400 or MPS-24A power supply (refer to Figure 3).

Note:
The MPM-3 must be installed with the mounting hardware supplied with it. Any original mounting screws in either power supply’s PC board must be removed from the MPM-3 installation site prior to installation of the MPM-3.