Programming Your
SmartStat TH115 Series Thermostat

Set the Thermostat Operation Mode Switches

Remove the faceplate from the base unit and locate the three switches on the rear of the faceplate. For proper operation of the display and the fl our warming system, all three switches should be in the UP position. Refi t the faceplate.

Set the Day and Time

Open the side panels on the thermostat and put the On/Standby switch
to On. Press the Day button as many times as necessary to set the
thermostat to the correct day.
Press the Hour and Min buttons to set the correct time.
(PM hours are displayed with PM to the left of the time.
There is no such annotation for AM).

Program the Time Settings

Unless you want to leave your thermostat at the same temperature 24/7, you will need to set up warming periods. You may program up to four periods per day.
As a default, this thermostat is set to perform two warming periods Monday – Friday (6:00 am – 8:30 am & 5:00 pm – 11:00 pm), and one warming period Saturday and Sunday (6:00 am – 11:00 pm). To modify this schedule, you will need to enter the Programming mode.

  1. Press Pgm. The screen will show a house with the number 1 inside ( ). This is the start of the fi rst warming period.
  2. To program the same settings for every day of the week, press and hold Day for 3 seconds. All 7 days will then appear on the screen.
  3. Use the Hour and Min buttons to select the start time of the fi first warming period (default 6:00 am).
  4. Press Pgm to show the second house with the number 2 inside ( ).
  5. Use the Hour and Min buttons to select the end time of the fi first warming period (default 8:30 am). If you only require one period each day, you will skip this setting by pressing the Clear button.
  6. Press Pgm to show the third house with the number 3 inside ( ).
  7. Use the Hour and Min buttons to select the start time of the second warming period (default 5:00 pm). If you only require one warming period each day, you will skip this setting by pressing the Clear button.
  8. Press Pgm to show the fourth house with the number 4 inside ( ).
  9. Use the Hour and Min buttons to select the end time of the second heating period (default 11:00 pm).
  10. Press the Mode/Ret button to show the Clock icon ( ), indicating the thermostat is now in Automatic Mode.

Set the Comfort and Economy Temperatures

During the programmed periods, the thermostat will operate at a Comfort temperature ( ). Between the programmed periods, the thermostat will set the temperature back to the Economy temperature ( ).
The default Comfort setting is a fl or temperature of 82 °F. To modify this temperature, use t he Up ( ) and Down ( ) buttons to reach the desired temperature, and immediately press and hold the Comfort ( ) button for 3 seconds. After another 5 seconds, the current fl or temperature will again be displayed.
The default Economy setting is a fl or temperature of 68 °F. To modify this temperature, use the Up ( ) and Down ( ) buttons to reach the desired temperature, and immediately press and hold the Economy ( ) button for 3 seconds. After another 5 seconds, the current fl or temperature will again be displayed.

Recommendations

The commonly preferred Comfort temperature is between 80 °F and 85 °F. If you choose an Economy temperature that is much lower than the Comfort temperature, the thermostat will take longer to reach the Comfort temperature. An Economy temperature of between 70 °F and 75 °F will ensure that the thermostat will return quickly to the Comfort temperature while using relatively little electricity. Every installation is different (subfl for, fl flooring, insulation, perceived comfort level), and it is up to the end user to fi and their most favorable settings.
An Economy temperature of between 70 °F and 75 °F will ensure that the thermostat will return quickly to the Comfort temperature while using relatively little electricity. Every installation is different (subfl for, fl flooring, insulation, perceived comfort level), and it is up to the end user to fi nd their most favorable settings.

Manual and Automatic Modes

The thermostat can be switched between Manual and Automatic modes by pressing the Mode/Ret button. Manual mode is indicated by the hand ( ) icon and Automatic mode is indicated by the clock ( ) icon. Time and Temperature settings will only be respected in the Automatic ( ) mode.
In Manual ( ) mode, the thermostat will hold the temperature constant at whatever level it has been set with the Up ( ) and Down ( ) buttons.
For further information or for personalized assistance in setting your thermostat, please call WarmlyYours at 800-875-5285.

For additional support and installation instructions,
please visit or scan our support QR code:
https://www.warmlyyours.com/support/sku/TH115-AF-GA-08  24/7 Installation Support
Lifetime Technical Assistance
www.WarmlyYours.com
800-875-5285

Documents / Resources

| WarmlyYours TH115-AF-GA-08 SmartStat TH115 Series Thermostat [pdf] Instruction Manual