DELL S6000 10-40GbE ToR Switch User Manual
- June 12, 2024
- Dell
Table of Contents
- Document Revision History
- New Dell Networking OS Version 9.14(2.12) Features
- Changes to Default Behavior and CLI Syntax
- Restrictions
- Supported Hardware
- S6000 Upgrade Procedures: Overview
- Upgrading the S6000 Dell Networking OS Image and Boot Code
- Upgrading the CPLD
- Upgrading the CPLD Image
- VLT Upgrade Procedure
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Support Resources
- Finding Documentation
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DELL S6000 10-40GbE ToR Switch User Manual
Document Revision History
Table 1. Revision History
Date | Description |
---|---|
2022–03 | Initial release. |
New Dell Networking OS Version 9.14(2.12) Features
The following features are integrated into the Dell Networking 9.14.2 branch through this release: None
Changes to Default Behavior and CLI Syntax
- If you are upgrading from an earlier OS9 version to 9.14.2.x, ensure you first upgrade to version 9.13.0.0 before upgrading to the required version of 9.14.2.x to prevent any issues during the upgrade procedure.
Restrictions
-
Prerequisite steps to upgrade the Dell Networking OS from earlier version to 9.14.2.0 or later:
- Uninstall the older version of the Open Automation (OA) package
- Upgrade the Dell Networking OS to 9.14.2.0 or later version
- Install the following OA packages from the respective upgraded version:
a. SmartScripts
b. Puppet
c. Open management infrastructure (OMI)
d. SNMP MIB
-
Prerequisite steps to downgrade the Dell Networking OS from 9.14.2.0 or later to the earlier version:
- Uninstall the OA package of 9.14.2.0 or later version
- Downgrade the Dell Networking OS to an earlier version
- Install the respective OA package from an earlier version
For more information about installing, uninstalling and upgrading the Dell Networking OS and OA package, refer the respective Dell System Release Notes.
-
If you downgrade the Dell Networking OS version from 9.14.2.12 to 9.11.0.0 or any older versions, the system displays the following error message even though there is no functional impact:
CDB boot error: C.cdb file format
Before downgrading, save the current configuration and then remove the CDB files (confd_cdb.tar.gz.version and confd_cdb.tar.gz). To remove the files, use the following steps:
Dell#write memory
Dell#delete flash://confd_cdb.tar.gz.version
Dell#delete flash://confd_cdb.tar.gz
Dell#reload
- While deploying the system in the normal-reload mode in BMP configuration, use the ip ssh server enable command at the beginning of the startup configuration if the write memory command is used at the end of the configuration.
- REST API does not support AAA authentication.
- The following features are not available in the Dell Networking OS from version 9.7(0.0):
- PIM ECMP
- Static IGMP join (ip igmp static-group)
- IGMP querier timeout configuration (ip igmp querier-timeout)
- IGMP group join limit (ip igmp group join-limit)
- Half-Duplex mode is not supported.
- When FRRP is enabled in a VLT domain, no flavor of Spanning tree should concurrently be enabled on the nodes of that specific VLT domain. In essence FRRP and xSTP should not co-exist in a VLT environment.
Supported Hardware
The following hardware is supported with this platform:
Hardware
- S6000 chassis
- 32 40Gbps QSFP+ ports
- 2 AC/DC PSUs
- 3 fan subsystems
NOTE: If all the three fan trays are found to be empty or faulty, the system will shut down after one minute.
NOTE: The rear rack mounting bracket (SA-01-RMB-8) will fit only into racks with depths in the following ranges:
- 22.98 in. to 24.65 in.
- 27.86 in. to 30.34 in.
The following informational error message appear when a USB thumb drive is inserted or removed from the system. No action needs to be taken when these messages appear. Internal Messages
Dell#
Dell# umass0 at uhub3 port 1 configuration 1 interface 0
umass0: vendor 0x0930 USB Flash Memory, rev 2.00/1.10, addr 3
umass0: using SCSI over Bulk-Only
scsibus0 at umass0: 2 targets, 1 lun per target
sd0 at scsibus0 target 0 lun 0: <, USB Flash Memory, PMAP> disk removable Feb
21 15:17:42: %S6000:0 %KERN-2-INT: umass0 at uhub3 port 1 configuration 1
interface 0
Feb 21 15:17:42: %S6000:0 %KERN-2-INT: umass0: vendor 0x0930 USB Flash Memory,
rev
2.00/1.10, addr 3
Feb 21 15:17:42: %S6000:0 %KERN-2-INT: umass0: using SCSI over Bulk-Only
Feb 21 15:17:42: %S6000:0 %KERN-2-INT: scsibus0 at umass0: 2 targets, 1 lun
per target
Feb 21 15:17:42: %S6000:0 %KERN-2-INT: sd0 at scsibus0 target 0 lun 0: <, USB
Flash
Memory, PMAP> disk removable
sd0: 3850 MB, 966 cyl, 255 head, 32 sec, 512 bytes/sect x 7884800 sectors
Feb 21 15:17:43: %S6000:0 %KERN-2-INT: sd0: 3850 MB, 966 cyl, 255 head, 32
sec, 512
bytes/sect x 7884800 sectors
Feb 21 15:17:47: %S6000:0 %POLLMGR-2-USER_FLASH_STATE: USB flash disk inserted
in
‘usbflash:’
Removal Messages
Dell#
Dell#umass0: at uhub3 port 1 (addr 3) disconnected
sd0(umass0:0:0:0): generic HBA error
sd0: detached
scsibus0: detached
umass0: detached
Feb 21 15:17:36: %S6000:0 %KERN-2-INT: umass0: at uhub3 port 1 (addr 3)
disconnected
Feb 21 15:17:36: %S6000:0 %KERN-2-INT: sd0(umass0:0:0:0): generic HBA error
Feb 21 15:17:36: %S6000:0 %KERN-2-INT: sd0: detached
Feb 21 15:17:36: %S6000:0 %KERN-2-INT: scsibus0: detached
Feb 21 15:17:36: %S6000:0 %KERN-2-INT: umass0: detached
Feb 21 15:17:37: %S6000:0 %POLLMGR-2-USER_FLASH_STATE: USB flash disk removed
from
‘usbflash:’
S6000 Upgrade Procedures: Overview
To upgrade the Dell Networking OS to the latest version, complete these steps:
NOTE: When upgrading from an earlier version of OS9 (example: 9.10.0.1)
to 9.14.2.x, first upgrade to 9.13.0.0 to prevent any issues during the
upgrade procedure.
- Upgrading the S6000 Dell Networking OS Image and Boot Code
- Upgrading the CPLD
- VLT Upgrade Procedure
Upgrading the S6000 Dell Networking OS Image and Boot Code
The S6000 system is pre-loaded with default Dell Networking OS software.
NOTE: If you downgrade from Dell Networking OS version 9.14(2.12) to
version 9.6(0.0) or any version prior to 9.6(0.0), any existing quad mode
configuration on the following ports is removed: 4, 12, 20, 28, 100, 108, 116,
and 124
NOTE: If you downgrade from Dell Networking OS version 9.14(2.12) to
9.0(2.0), remove any existing quad mode configuration from the following 40G
ports: 4, 12, 20, 28, 100, 108, 116, and 124. To remove any quad mode
configuration, use the no stack-unit port portmode quad command in
CONFIGURATION mode and then save the configuration using the write memory
command in EXEC PRIVILEGE mode.
NOTE: Before upgrading the OS to version 9.14(2.12), uninstall the older
version of the Open Automation package. Upgrade the OS to 9.14(2.12) and then
install the latest OA package. If you downgrade the OS from version 9.14(2.12)
to an earlier version, uninstall the older OA package first. Downgrade the OS
to an earlier version and then install the relevant OA package version.
Bare Metal Provisioning
NOTE: If you are using Bare Metal Provisioning (BMP), refer to the Bare
Metal Provisioning chapter in the Dell Networking OS Configuration Guide or
the Open Automation Guide.
Manual Upgrade Procedure
Follow these steps carefully to upgrade your S6000 systems:
-
Dell Networking recommends that you back up your startup configuration and any important files and directories to an external media prior to upgrading the system.
-
Upgrade the Dell Networking OS in flash partition A: or B:
EXEC Privilege Mode upgrade system [flash: | ftp: | stack-unit <0-5 | all> | tftp: | scp: | usbflash:] [A: | B:] Dell# upgrade system ftp: a:
Address or name of remote host []: 10.16.127.35
Source file name []: FTOS-SI-9.14.2.12.bin
User name to login remote host: ftpuser
Password to login remote host:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!……………………………………….
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………………………………..
………………………………………………………………..!
62056018 bytes successfully copied
System image upgrade completed successfully. -
In case of a stack setup, upgrade the Dell Networking OS for the stacked units. EXEC Privilege Mode upgrade system stack-unit [0-11 | all] [A: | B:] If A: is specified in the command, the Dell Networking OS version present in Management unit’s A: partition will be pushed to the stack units. If B: is specified in the command, the Management unit’s B: will be pushed to the stack units. Upgrade of stack units can be done on individual units by specifying the unit id [0-5] or on all units by using all in the command.
Dell#upgrade system stack-unit all A:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Image upgraded to all
Dell# -
Verify the Dell Networking OS has been upgraded correctly in the upgraded flash partition. EXEC Privilege Mode
show boot system stack-unit [0–5 | all] Dell#show boot system stack-unit all
Current system image information in the system:Type Boot Type A B
———————————————————–
stack-unit 0 FLASH BOOT 9.14(2.12)[boot] 9.14(2.11)
stack-unit 1 is not present.
stack-unit 2 is not present.
stack-unit 3 is not present.
stack-unit 4 is not present.
stack-unit 5 is not present. -
Upgrade the S6000 Boot Flash and Boot Selector images. EXEC Privilege Mode upgrade boot [all | bootflash-image | bootselector-image] stack-unit [0-5 | all] [booted | flash: | ftp: | scp: | tftp: | usb flash:] Dell Networking OS version 9.14(2.12) requires S6000 Boot Flash image version 3.1.1.7 and Boot Selector image version 3.1.0.3. The Boot Flash and Boot Selector images can be upgraded together by selecting all in the command. If the user wishes to upgrade Boot Flash image or Boot Selector image separately, the options bootflash imageor boot selector-image needs to be given separately in the command. The booted option is used to upgrade the Boot flash and Boot Selector images to the image versions packed with the loaded Dell Networking OS image. The Boot Flash and Boot Selector image versions packed with the loaded Dell Networking OS can be found using the show os-version command in EXEC PRIVILEGE mode.
NOTE: The Boot Flash version packed in Dell Networking OS 9.14(2.12) for S6000 system is 3.1.1.7. Upgrade of Boot Flash to version 3.1.1.7 is not mandatory for proper functioning of the system.
Dell#upgrade boot bootflash-image stack-unit 0 ftp:
Address or name of remote host []: 10.16.127.35
Destination file name []: FTOS-SI-9.14.2.12.bin
User name to login remote host: ftpuser
Password to login remote host:
Current Boot information in the system:Card BootFlash Current Version New Version
—————————————————————-
Unit0 Boot Flash 3.1.1.4 3.1.1.7
-
Warning – Upgrading boot flash is inherently risky and should only *
-
be attempted when necessary. A failure at this upgrade may cause *
-
a board RMA. Proceed with caution ! *
Proceed upgrade Boot Flash image for stack-unit 0 [yes/no]: yes
!!!!!!!!!
Bootflash image upgrade for stack-unit 0 completed successfully.
Dell#upgrade boot bootselector-image stack-unit 0 ftp:
Current Boot information in the system:Card BootSelector Current Version New Version
————————————————————–
Unit0 Boot Selector 3.1.0.3 3.1.0.3
-
Warning – Upgrading boot selectors is inherently risky and should *
-
only be attempted when necessary. A failure at this upgrade may *
-
cause a board RMA. Proceed with caution ! *
Proceed upgrade Boot Selector image for stack-unit 0 [yes/no]: yes
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Bootselector image upgrade for stack-unit 0 completed successfully.-
Change the Primary Boot Parameter of the S6000 to the upgraded partition A: or B: CONFIGURATION Mode boot system stack-unit [0–5 | all] primary system: [A: | B: | tftp: | ftp:]
-
Save the configuration so that the configuration will be retained after a reload using write memory command.
EXEC Privilege Mode write memory
Dell#write memory
!00:22:59: %STKUNIT0-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config in flash by default
Dell# -
Reload the unit.
EXEC Privilege Mode reload
Command : reload
Mode : EXEC PRIVILEGE
Dell#reload
Proceed with reload [confirm yes/no]: y
00:23:50: %STKUNIT0-M:CP %CHMGR-5-RELOAD: User request to reload the chassis -
Verify the S6000 has been upgraded to the Dell Networking OS version 9.14(2.12).
EXEC Privilege Mode show version
Dell#show version
Dell Real Time Operating System Software
Dell Operating System Version: 2.0
Dell Application Software Version: 9.14(2.12)
Copyright (c) 1999-2021 by Dell Inc. All Rights Reserved.
Build Time: Mon Feb 21 09:27:40 2022
Build Path: /build/build03/SW/SRC
Dell Networking OS uptime is 3 minute(s)
System image file is “system://A”
System Type: S6000
Control Processor: Intel Centerton with 3 Gbytes (3203911680 bytes) of memory,
core(s) 2.
16G bytes of boot flash memory.
1 32-port TE/FG (SI)
28 Ten GigabitEthernet/IEEE 802.3 interface(s)
25 Forty GigabitEthernet/IEEE 802.3 interface(s) -
Verify that the S6000 has been upgraded to the latest Boot Flash and Boot Selector images
EXEC Privilege Mode show system stack-unit [0-5] Dell#show system stack-unit 0
— Unit 0 —
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S6000 – 32-port TE/FG (SI)
Current Type : S6000 – 32-port TE/FG (SI)
Master priority : 0
Hardware Rev : 4.0
Num Ports : 128
Up Time : 3 min, 24 sec
Dell Networking OS Version : 9.14(2.12)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : 3.1.1.7
Boot Selector : 3.1.0.3
Memory Size : 3203911680 bytes
Temperature : 37C
Voltage : ok
Serial Number : NA
Part Number : 08YWFG Rev A00
Vendor Id : DL
Date Code : 02212022
Country Code : CN
Piece Part ID : CN-08YWFG-28298-398-0104
PPID Revision : A00
Service Tag : BX71VS1
Expr Svc Code : 259 518 346 57
Auto Reboot : enabled
Burned In MAC : 90:b1:1c:f4:9c:c0
No Of MACs : 3
— Power Supplies —
Unit Bay Status Type FanStatus FanSpeed(rpm)
—————————————————————————
0 0 up AC up 10368
0 1 absent absent 0
— Fan Status —
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
————————————————————————————
0 0 up up 10031 up 10031
0 1 up up 10031 up 10031
0 2 up up 10134 up 10134
Speed in RPM
-
SMARTSCRIPTS
To uninstall and install new SMARTSCRIPTS packages after upgrading to Dell
Networking OS, refer to the Open Automation Guide.
Upgrading the CPLD
The S6000 system with Dell Networking OS Version 9.14(2.12) requires System CPLD revision 10, Master CPLD revision 12, and Slave CPLD revision 10.
Verify that a CPLD upgrade is required
NOTE: If your CPLD revisions are higher than the ones shown here, DO
NOT make any changes. If you have questions regarding the CPLD revision,
contact technical support.
Use the following command to identify the CPLD version:
Dell#show revision
— Stack unit 0 —
S6000 SYSTEM CPLD : 10
S6000 MASTER CPLD : 12
S6000 SLAVE CPLD : 10
Use the following command to view CPLD version that is associated with the
Dell Networking OS image:
Dell#show os-version
RELEASE IMAGE INFORMATION :
———————————————————————
Platform Version Size ReleaseTime
S-Series:SI 9.14(2.12) 62072761 Feb 21 2022 09:48:25
TARGET IMAGE INFORMATION :
———————————————————————
Type Version Target checksum
runtime 9.14(2.12) Control Processor passed
BOOT IMAGE INFORMATION :
———————————————————————
Type Version Target checksum
boot flash 3.1.1.7 Control Processor passed
BOOTSEL IMAGE INFORMATION :
———————————————————————
Type Version Target checksum
boot selector 3.1.0.3 Control Processor passed
FPGA IMAGE INFORMATION :
———————————————————————
Card FPGA Name Version
stack-unit 0 S6000 SYSTEM CPLD 10
stack-unit 0 S6000 MASTER CPLD 12
stack-unit 0 S6000 SLAVE CPLD 10
Upgrading the CPLD Image
NOTE: The upgrade fpga-image stack-unit 0 booted command is hidden when
using the FPGA Upgrade feature in the CLI. However, it is a supported command
and will be accepted when entered as documented.
NOTE: Ensure that the BIOS version is 3.1.0.3 or above. You can verify
this version using the show system stackunit 0 command.
To upgrade the CPLD image on S6000, follow these steps:
-
Upgrade the CPLD image. EXEC Privilege Mode
upgrade fpga-image stack-unit booted
Dell# upgrade fpga-image stack-unit 0 booted
Current information for the system:Card Device Name Current Version New Version
———————————————————————
Unit0 S6000 SYSTEM CPLD 10 10
Unit0 S6000 MASTER CPLD 12 12
Unit0 S6000 SLAVE CPLD 10 10
-
Warning – Upgrading FPGA is inherently risky and should *
-
only be attempted when necessary. A failure at this upgrade may *
-
cause a board RMA. Proceed with caution ! *
Upgrade image for stack-unit 0 [yes/no]: yes
FPGA upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result :Unit 0 FPGA upgrade successful Unit 0. Please power cycle to take effect.
-
Power cycle the system physically. Switch off the system by unplugging the power chords from the REAR PSUs and wait until the PSU FAN–REAR STATUS LED is completely OFF.
NOTE: Do not switch on the system with PSU–REAR LED glowing AMBER. -
Switch on the system and wait for the Dell prompt. The CPLD version can be verified using the show revision command.
EXEC Privilege Mode show revision
Dell#show revision
— Stack unit 0 —
S6000 SYSTEM CPLD : 10
S6000 MASTER CPLD : 12
S6000 SLAVE CPLD : 10
-
NOTE: Do not power off the system while FPGA upgrade is in progress. For any queries, contact technical support
VLT Upgrade Procedure
Follow this procedure to upgrade the system from release 9.4(2.8) to the latest version in a VLT setup:
-
Upgrade the system-flash partition A or B with the new image on both VLT peers.On both the VLT peers, set Primary boot parameter to boot the system from upgraded system flash partition [A or B].You can enter one of the following options:flash — Copies from flash file system (flash://filepath).ftp — Copies from remote file system (ftp://userid:password@hostip// filepath).scp — Copies from remote file system (scp://userid:password@hostip//filepath).tftp — Copies from remote file system (tftp://hostip/filepath).
EXEC Privilege Mode
upgrade system [flash: | ftp: | scp: | tftp: | usbflash:] [A: | B:] -
Reload or power-cycle one of the VLT peers (For Example, Peer 2).
EXEC Privilege Mode reload or power cycle -
Wait for Peer 2 to come up; VLT adjacency will be established. (Peer 2 – new image and Peer 1 – old image).
-
Wait for the Peer 2 to bring up all VLT LAG ports. Use the command show vlt detail to confirm all VLT ports in the local chassis are active.
EXEC Privilege Mode show vlt detail -
Following upgrade, use the write memory command to save the running-config to memory.
EXEC Privilege Mode write memory -
Ensure both the nodes are now forwarding traffic.
-
When all VLT ports are active on the Peer 2, repeat steps 2 through 5 for the Peer 1.
Documentation Corrections
This section describes the errors identified in the current release of the Dell Networking OS.
- The router bgp command allows you to configure only one L3 interface with an IPv4 address. The Configuration guide does not mention this limitation and will be corrected in the next release of the guide.
Deferred Issues
Issues that appear in this section were reported in Dell Networking OS version 9.14(2.0) as open, but have since been deferred. Deferred caveats are those that are found to be invalid, not reproducible, or not scheduled for resolution. Deferred issues are reported using the following definitions.
Category Description
PR# Problem Report number that identifies the issue.
Severity S1 — Crash: A software crash occurs in the kernel or a running
process that requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature
unusable, which can have a pervasive impact on the system or network, and for
which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or
negatively effects the network for which there exists a work-around that is
acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little
or no network impact for which there might be a work-around.
Synopsis Synopsis is the title or short description of the issue.
Release Notes Release Notes description contains more detailed
information about the issue.
Work around Work around describes a mechanism for circumventing,
avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the
work-around is unnecessary, as the version of code for which this release note
is documented has resolved the caveat.
Deferred S6000 9.14(2.0) Software Issues
Issues that appear in this section were reported in Dell Networking OS version
9.14(2.0) as open, but have since been deferred. Deferred caveats are those
that are found to be invalid, not reproducible, or not scheduled for
resolution. The following issues have been deferred in the Dell Networking OS
version 9.14(2.0): None.
Fixed Issues
Fixed issues are reported using the following definitions.
Category Description
PR# Problem Report number that identifies the issue.
Severity S1 — Crash: A software crash occurs in the kernel or a running
process that requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature
unusable, which can have a pervasive impact on the system or network, and for
which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or
negatively effects the network for which there exists a work-around that is
acceptable to the customer
Category Description
S4 — Minor: A cosmetic issue or an issue in a minor feature with little
or no network impact for which there might be a work-around.
Synopsis Synopsis is the title or short description of the issue.
Release Notes Release Notes description contains more detailed
information about the issue.
Work around Work around describes a mechanism for circumventing,
avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the
work-around is unnecessary, as the version of code for which this release note
is documented has resolved the caveat.
Fixed S6000 9.14(2.12) Software Issues
NOTE: Dell Networking OS 9.14(2.12) includes fixes for caveats addressed
in the previous 9.14 releases. Refer to the respective release notes
documentation for the list of caveats fixed in the earlier 9.14 releases. The
following caveats have been fixed in Dell Networking OS version 9.14(2.12):
PR# 170240
Severity: Sev 2
Synopsis: AAA accounting request displays an incorrect calling station-
id.
Release Notes: AAA accounting request displays an incorrect calling
station-id.
Workaround: None
PR# 170275
Severity: Sev 2
Synopsis: SSH stops functioning after upgrade to 9.14.2.11.
Release Notes: SSH stops functioning after upgrade to 9.14.2.11.
Workaround: None
Known Issues
Known issues are reported using the following definitions.
Category Description
PR# Problem Report number that identifies the issue.
Severity S1 — Crash: A software crash occurs in the kernel or a running
process that requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature
unusable, which can have a pervasive impact on the system or network, and for
which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or
negatively effects the network for which there exists a work-around that is
acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little
or no network impact for which there might be a work-around.
Synopsis Synopsis is the title or short description of the issue.
Category Description
Release Notes Release Notes description contains more detailed
information about the issue.
Work around Work around describes a mechanism for circumventing,
avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the
work-around is unnecessary, as the version of code for which this release note
is documented has resolved the caveat.
KnownS6000 9.14(2.12) Software Issues
The following caveats are open in Dell Networking OS version 9.14(2.12): None
Support Resources
The following support resources are available for theS6000 system.
Documentation Resources
This document contains operational information specific to the S6000 system.
For information about using the S6000, refer to the following documents at http://www.dell.com/support:
- Installing the S6000 System
- Quick Start Guide
- Dell Networking Command Line Reference Guide for the S6000 System
- Dell Networking Configuration Guide for the S6000 System
For more information about hardware features and capabilities, refer to the
Dell Networking website at https://www.dellemc.com/networking.
For more information about the open network installation environment
(ONIE)-compatible third-party operating system, refer to http://onie.org.
Issues
Incorrect behavior or unexpected caveats are listed as the Problem Report (PR)
numbers within the appropriate sections.
Finding Documentation
This document contains operational information specific to the S6000 system.
- For information about using the S6000, refer to the documents at http://www.dell.com/support.
- For more information about hardware features and capabilities, refer to the Dell Networking website at https://www.dellemc.com/networking.
- For more information about the open network installation environment (ONIE)-compatible third-party operating system, refer to http://onie.org.
Contacting Dell
NOTE: If you do not have an active Internet connection, you can find
contact information on your purchase invoice, packing slip, bill, or Dell
product catalog.
Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues:
NOTE: A NOTE indicates important information that helps you make better
use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss
of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
References
- Computers, Monitors & Technology Solutions | Dell USA
- Support | Dell US
- Dell Networking Solutions | Dell USA
- Dell Networking Solutions | Dell USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>