GENERAL INFORMATION
PRODUCT DESCRIPTION
The UltraCon SS4 anchor is a 410 stainless steel screw anchor for light to medium duty applications in concrete and masonry block base materials. The screw anchor is fast and easy to install and provides a neat, finished appearance. UltraCon SS4 anchors feature a Stalgard coating and provide enhanced corrosion resistance over carbon steel fasteners.
GENERAL APPLICATIONS AND USES
- Screen Enclosures
- Storm Shutters
- Light Duty Fixtures
- Light Duty Industrial Mounts
FEATURES AND BENEFITS
+ Special heat treatment to protect inherent corrosion resistance of the 410
stainless steel material
+ Stalgard coating provides 1000 hours of salt spray protection when tested
in accordance with ASTM B117
HEAD STYLES
- Hex Washer Head
- TrimFit® Flat Head
ANCHOR MATERIALS
- Type 410 Stainless Steel with Stalgard® Coating
ANCHOR SIZE RANGE
- 1/4″ diameter x 1-1/4″ to 6″ lengths
SUITABLE BASE MATERIALS
- Normal-Weight Concrete
- Hollow Concrete Masonry (CMU)
- Grout-Filled Concrete Masonry (CMU)
APPROVALS AND LISTINGS
- Tested in accordance with ASTM E488
- Miami-Dade County Notice of Acceptance (NOA) No. 21-0201.08
- Florida Statewide Product Approval FL29068.1
GUIDE SPECIFICATIONS
CSI Divisions: 03 16 00 – Concrete Anchors, 04 05 19.16 – Masonry Anchors and 05 05 19 – PostInstalled Concrete Anchors. Screw anchors shall be UltraCon SS4 as supplied by DEWALT, Towson, MD. Concrete screw anchors shall be installed in accordance with published instructions and the Authority Having Jurisdiction.
MATERIAL SPECIFICATIONS
Anchor Component
|
Specification
---|---
Anchor body
|
410 stainless steel
Coating/Plating/Finish
|
stalgard® 1000 hour rating per AsTM b117 salt spray test
Note: 410 stainless steel fasteners in contact with aluminum and aluminum alloys is not recommended in accordance with AIsI ss 502 / ssINA guidelines.
INSTALLATION SPECIFICATIONS
Anchor Property / Setting Information
|
**Notation**
| Anchor Diameter, d a
---|---|---
1/4″ HEX|
1/4″ TFH
Anchor shank Diameter (in)|
da
| 0.193|
0.193
Ultracon+ Drill bit size (in)|
dbit
| 3/16|
3/16
Typ. Fixture Clearance hole (in)|
dh
| 5/16|
5/16
Head Height (in)|
–
| 9/64|
3/16
Head Width (in)|
–
| 5/16|
13/32
Washer o.D. (in)|
–
| 13/32|
N/A
Washer Thickness (in)|
–
| 1/32|
N/A
Hex Driver (in) / Phillips Driver|
–
| 5/16|
3
1. For minimum nominal embedment depths, hnom, see the performance data tables. The minimum hole depth, ho, is 1/4-inch more than the selected nominal embedment depth.
410 Stainless Steel UltraCon SS4 Identification
The head markings consist of a “D” for the DEWALT brand, the number “4” for the 410 series stainless steel classification, and the length code
UltraCon SS4 Length Code Identification System
Length ID marking on head
| **| A| B| C| D| E| F| G**|
H
---|---|---|---|---|---|---|---|---|---
overall anchor length ℓ anch (inches)
|
From
|
1″
| 1-1/2″| 2″| 2-1/2″| 3″| 3-1/2″| 4″| 4-1/2″| 5-1/2″
Up to but not including| 1-1/2″| 2″| 2-1/2″| 3″| 3-1/2″| 4″| 4-1/2″| 5-1/2″|
6-1/2″
Anchor Detail
Nomenclature
da = Diameter of anchor
dbit = Diameter of drill bit
dh = Diameter of fixture clearance hole
hnom = Minimum embedment depth
h = Base material thickness
The minimum value of h should be 1.5hnom or 3″ whichever is greater
ho = Minimum hole depth
INSTALLATION INSTRUCTIONS
Installation Instruction for UltraCon SS4
Step 1
Using the proper drill bit size, drill a hole into the base material to the
required depth, ho, which is a 1/4-inch deeper than the minimum embedment
depth, hnom.
Step 2
Remove dust and debris from the hole during drilling (e.g. dust extractor) or
following drilling (e.g. suction, forced air) to extract loose particles
created by drilling.
Step 3
Attach a UltraCon+ installation socket tool for the selected anchor size to a
percussion drill and set the drill to rotary only mode. Mount the screw anchor
head into the socket. For flat head versions a bit tip must be used with the
socket tool.
Step 4
Place the point of the UltraCon SS4 through the fixture into the pre-drilled
hole and drive the anchor in one steady continuous motion until it is fully
seated at the proper embedment. The driver will automatically disengage from
the head of the screw.
PERFORMANCE DATA
Ultimate Load Capacities for UltraCon SS4 in Normal-Weight Concrete1
Nominal Anchor Diameter| Min. Edge Dist. (in.)| Min.
Spacing (in.)| Min. Embed. (in.)| Minimum Concrete Compressive
Strength
---|---|---|---|---
2500 psi| 3000 psi
Tension (lbs.)| Shear (lbs.)| Tension (lbs.)|
Shear (lbs.)
1/4| 1| 1-1/2| 1-1/2″| 340| 265| 365| 280
1-3/4″| 540| 385| 580| 410
3| 1-1/2″| 610| 275| 660| 295
1-3/4″| 1235| 510| 1330| 540
2-1/2| 1-1/2| 1-1/2″| 720| 730| 770| 775
1-3/4″| 1275| 1900| 1375| 2020
3| 1-1/2″| 885| 990| 955| 1050
1-3/4″| 1515| 2200| 1630| 2335
- Tabulated load values are for anchors installed in uncracked concrete. Concrete compressive strength must be at the specified minimum at the time of installation
- Ultimate load capacities must be reduced by a minimum safety factor of 4.0 or greater to determine allowable working load. Consideration of safety factors of 10 and higher may be necessary depending upon the application such as life safety or overhead.
Allowable Load Capacities for UltraCon SS4 in Normal-Weight Concrete1
Nominal Anchor Diameter| Min. Edge Dist. (in.)| Min.
Spacing (in.)| Min. Embed. (in.)| Minimum Concrete Compressive
Strength
---|---|---|---|---
2500 psi| 3000 psi
Tension (lbs.)| Shear (lbs.)| Tension (lbs.)|
Shear (lbs.)
1/4
| 1| 1-1/2| 1-1/2″| 85| 65| 90| 70
1-3/4″| 135| 95| 145| 100
3| 1-1/2″| 150| 65| 165| 70
1-3/4″| 305| 125| 330| 135
2-1/2| 1-1/2| 1-1/2″| 180| 180| 190| 190
1-3/4″| 315| 475| 340| 505
3| 1-1/2″| 220| 245| 235| 260
1-3/4″| 375| 550| 405| 580
- Allowable load capacities listed are calculated using an applied safety factor of 4.0. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead.
Ultimate Load Capacities for UltraCon SS4 in Hollow and Grout-Filled Concrete Masonry1,2
Nominal Anchor Diameter
(in.)
| Min. Edge Dist. (in.)| Min. Spacing (in.)| Min.
Embed. (in.)| Hollow Bock| Grout-Filled Block
---|---|---|---|---|---
Tension (lbs.)| Shear (lbs.)| Tension (lbs.)|
Shear (lbs.)
1/4| 1| 1-1/2| 1-1/4| 530| 220| 685| 280
2| –| –| 1090| 280
3| 1-1/4| 620| 360| 950| 415
2| –| –| 1460| 415
2-1/2| 1-1/2| 1-1/4| 530| 445| 1025| 455
2| –| –| 1090| 900
3| 1-1/4| 620| 615| 1060| 1000
2| –| –| 1930| 1510
- Tabulated load values are for anchors installed in grout-filled concrete block conforming to AsTM C90 with a minimum block compressive strength of 2000 psi and minimum grout compressive strength of 1625 psi.
- Ultimate load capacities must be reduced by a minimum safety factor of 5.0 or greater to determine allowable working load. Consideration of safety factors of 10 and higher may be necessary depending upon the application such as life safety or overhead.
Allowable Load Capacities for UltraCon SS4 in Hollow and Grout-Filled Concrete Masonry1
Nominal Anchor Diameter (in.)| Min. Edge Dist. (in.)|
Min. Spacing (in.)| Min. Embed. (in.)| Hollow Bock|
Grout-Filled Block
---|---|---|---|---|---
Tension (lbs.)| Shear (lbs.)| Tension (lbs.)|
Shear (lbs.)
1/4| 1| 1-1/2| 1-1/4| 105| 40| 135| 55
2| –| –| 215| 55
3| 1-1/4| 120| 70| 190| 80
2| –| –| 290| 80
2-1/2| 1-1/2| 1-1/4| 105| 85| 205| 90
2| –| –| 215| 180
3| 1-1/4| 120| 120| 210| 200
2| –| –| 385| 300
- Allowable load capacities listed are calculated using an applied safety factor of 5.0. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead.
ORDERING INFORMATION
Silver Stalgard® UltraCon SS4
Cat. No.| **Screw Size| Approximate Thread Length|
****Pack Qty.| ****Carton Qty.
---|---|---|---|---
HWH| TFH**
DFM4EUH310| DFM4EUF310| 1/4″ X 1-1/4″| 1-1/8″| 100| 500
DFM4EUH315| DFM4EUF315| 1/4″ X 1-3/4″| 1-5/8″| 100| 500
DFM4EUH325| DFM4EUF325| 1/4″ X 2-1/4″| 1-7/8″| 100| 500
DFM4EUH335| DFM4EUF335| 1/4″ X 2-3/4″| 1-7/8″| 100| 500
DFM4EUH345| DFM4EUF345| 1/4″ X 3-1/4″| 1-7/8″| 100| 500
DFM4EUH355| DFM4EUF355| 1/4″ X 3-3/4″| 1-7/8″| 100| 500
DFM4EUH365| DFM4EUF365| 1/4″ X 4″| 1-7/8″| 100| 500
DFM4EUH375| –| 1/4″ X 5″| 1-7/8″| 100| 500
DFM4EUH385| –| 1/4″ X 6″| 1-7/8″| 100| 500
HWH = Hex Washer Head, TFH = TrimFit® Flat Head
Hex Head UltraCon ss4 Anchors are measured from below the washer while flat
head UltraCon ss4 anchors are measured end to end. To select the proper
minimum anchor length, determine the embedment depth required (e.g. required
to obtain desired load capacity). Then add the thickness of the fixture,
including any spacers or shims, to the embedment depth.
UltraCon+ Drill Bits
Cat. No. | Description |
---|---|
DW5382 | 3/16 x 7″ UltraCon+ sDs bit |
Installation Kit
Cat. No. | Description |
---|---|
**** DW5366 | UltraCon®+ Installation Kit includes: 5/32″ and 3/16″ UltraCon+ |
bit, 1/4″ and 5/16″ nutsetters, #2 and #3 Phillips bits, Phillips flat head adapter, percussion adapter, drive sleeve and 1/8″ allen wrench
Rotary Hammers
Cat. No. | Description |
---|---|
DCH273 | 20V Max* Xr brushless 1″ |
L-shape sDs Plus rotary Hammer
DCH133| 20V Max* Xr brushless 1″
D-Handle sDs Plus rotary Hammer
DCH172| AToMIC 20V MAX 5/8 in. brushless Cordless sDs Plus rotary Hammer
Accessories
Cat. No. | Description |
---|---|
DWH303DH | onboard Dust Extractor for 1″ sDs Plus Hammers |
DWH050 | Large Hammer Dust Extraction – Hole Cleaning |
DWH200 | Dust Extraction Tube Kit with Hose |
Dust Extractors
Cat. No. | Description |
---|---|
DCV585 | Flexvolt® 60V Max* Dust Extractor |
DVW010 | 8 Gallon Wet Dry Hepa/rrp Dust Extractor |
DWV012 | 10 Gallon Wet Dry Hepa/rrp Dust Extractor |
DWH161D1 | 20V Max* Xr brushless Universal Dust Extractor Kit |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>