Winco EC6010DR-T Vehicle Mounted Diesel Generator Instruction Manual
- June 12, 2024
- WINCO
Table of Contents
- Winco EC6010DR-T Vehicle Mounted Diesel Generator
- Product Information
- Product Usage Instructions
- SAFETY
- SPECIFICATIONS
- INTRODUCTION
- UNIT CAPABILITIES
- PREPARING THE UNIT
- CONNECTING FUEL SUPPLY
- TROUBLESHOOTING
- CALIFORNIA EVAPORATIVE EMISSION CONTROL **
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Winco EC6010DR-T Vehicle Mounted Diesel Generator
Product Information
- Model: EC6010DR/T EC6010KE-03/B
- Product Type: Generators
- Installation and Operator’s Manual: Included
- Serial Number: Unique to each generator
- Purchase Date: Fill in the date of purchase
- Dealer Name: Fill in the name of the dealer where the generator was purchased
- Dealer Phone #: Fill in the phone number of the dealer
Product Usage Instructions
- Installation and Setup:
- Unpack the generator carefully.
- Install the compartments as instructed.
- Lubricate the generator according to the manual.
- Follow the recommended oil for the generator.
- Use diesel fuel for operation
- Install the battery as per the instructions.
- Familiarize yourself with the control panel.
- Connect the fuel supply to the generator.
- Initial Start-Up:
- Follow the provided starting hints for a smooth start-up.
- Use the control panel to start the generator.
- Connect the loads to the generator.
- Basic Operation:
- Apply the loads gradually to avoid overloading.
- Ensure proper grounding of the generator.
- Follow wiring guidelines for safe operation.
- Engine Care:
- Adhere to the maintenance schedule provided.
- Change the oil as recommended.
- Regularly check the oil level.
- Clean or replace the air filter as required.
- Perform generator care as instructed.
- Exercising and Maintenance:
- Exercise the generator regularly as advised.
- Follow cleaning procedures to maintain performance.
- Troubleshoot any issues using the troubleshooting tables.
- Control Panel Wiring Diagram:
- Refer to the provided control panel wiring diagram for guidance.
- California EVAP Emission Control:
- Take note of California Proposition 65 warning regarding petroleum products.
- Visit www.P65Warning.ca.gov for more information.
- Limited Warranty:
- Consult the warranty section for information on warranty coverage.
Note: For detailed instructions and safety precautions, refer to the complete user manual provided with the generator.
SAFETY
This engine generator set has been designed and manufactured to allow safe, reliable performance. Poor maintenance, improper or careless use can result in potentially deadly hazards; from electrical shock, exhaust gas asphyxiation, or fire. Please read all safety instructions carefully before installation or use. Keep these instructions handy for future reference. Take special note and follow all warnings on the unit labels and in the manuals.
CALIFORNIA PROPOSITION 65
WARNING: This product contains crude oil, gasoline, diesel fuel and other
petroleum products, Antifreeze to which can expose you to chemicals including
toluene and benzene, Ethylene glycol (ingested) which are known to the State
of California to cause cancer, birth defects or other reproductive harm and
developmental issues.
For more information go to
www.P65Warning.ca.gov.
ANSI SAFETY DEFINITIONS
-
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. -
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. -
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
ELECTRICAL SHOCK –
The output voltage present in this equipment can cause fatal electric shock.
This equipment must be operated by a responsible person.
- Do not allow anyone to operate the generator without proper instruction.
- Guard against electric shock.
- Avoid contact with live terminals or receptacles.
- Use extreme care if operating this unit in rain or snow.
- Use only three-pronged grounded receptacles and extension cords.
- Be sure the unit is properly grounded to an external ground rod driven into the earth.
FIRE HAZARD –
Gasoline and other fuels present a hazard of possible explosion and/or fire.
- Do not refuel when the engine is running or hot.
- Keep fuel containers out of reach of children.
- Do not smoke or use open flame near the generator set or fuel tank.
- Keep a fire extinguisher nearby and know its proper use. Fire extinguishers rated ABC by NFPA are appropriate.
- Store fuel only in an approved container, and only in a well ventilated area.
- Follow local codes for closeness to combustible material.
DEADLY EXHAUST GAS –
Exhaust fumes from any gasoline engine contain carbon monoxide, an invisible,
odorless and deadly gas that must be mixed with fresh air.
- Operate only in well ventilated areas.
- Never operate indoors including attached garages
- Never operate the unit in such a way as to allow exhaust gases to seep back into closed rooms (i.e. through windows, walls, floors).
NOISE HAZARD –
Excessive noise is not only tiring, but continual exposure can lead to loss of
hearing.
Use hearing protection when working around this equipment for long periods of
time.
Keep your neighbors in mind when using this equipment.
CLEANLINESS –
Keep the generator and surrounding area clean.
- Remove all grease, ice, snow or materials that create slippery conditions around the unit.
- Remove any rags or other materials that could create a potential fire hazard.
- Carefully clean up any gas or oil spills before starting the unit.
SERVICING EQUIPMENT –
All service, including the installation or replacement of service parts,
should be performed only by a qualified technician.
- Use only factory approved repair parts.
- Do not work on this equipment when fatigued.
- Never remove the protective guards, covers, or receptacle panels while the engine is running.
- Use extreme caution when working on electrical components. High output voltage from this equipment can cause serious injury or death.
- Always avoid hot mufflers, exhaust manifolds, and engine parts. They can cause severe burns instantly.
- The use of the engine-generator set must comply with all national, state, and local codes.
SPECIFICATIONS
- Model EC6010DR/T EC6010KE-03/B
- Starting Watts 6,010
- Running Watts: EC6010DR/T 5,160, EC6010KE-03/B 5,000
- Volts 120/240
- Starting Amps 50/25
Running Amps
- EC6010DR/T 43/21.5
- EC6010KE-03/B 40/20
GENERATOR
- Generator Manufacturer Mecc Alte Spa
- Generator Model Number ES16F-160
- Part Number 16346-027
- Rotor Resistance 8.378 Ohms
- Stator Resistance 0.51 Ohms
- Regulation AVR
ENGINE
- Engine Manufacturer Kohler
- Engine Model Number KD440
- Fuel Type Diesel
- Oil Capacity 41.6 oz. (1.3 qts)
INTRODUCTION
TESTING POLICY
Before any generator is shipped from the factory, it is fully checked for
performance. The generator is loaded to its full capacity, and the voltage,
current, and frequency are carefully checked.
Rated output of generator is based on engineering tests of typical units, and
is subject to, and limited by, the temperature, altitude, fuel, and other
conditions specified by the manufacturer of applicable engines.
INTENDED USES
This engine generator set has been designed primarily for portable heavy duty
commercial use. Both 120 volt and 240 volt receptacles are provided in the
control panel to plug in your loads (lights, portable tools, and small
appliances). These units are dual wound generators, therefore the 120 volt
loads must be equally split with 1/2 of the rated capacity available on each
of the two 120 volt circuits.
This portable unit requires large quantities of fresh air for cooling the
engine and generator. For safety, long life and adequate performance, these
units should never be run in small compartments without positive fresh air
flow.
RESTRICTED USES
DO NOT operate generator where it could get wet or have pooling water near it.
This generator is NOT weatherproof. Failing to keep generator in a dry area
may cause an electrical shock, resulting in injury or death.
DO NOT operate and/or store the unit outside during inclement weather without
adequate protection from the elements. Failure to do so will damage the unit.
DO NOT remove from the cradle assembly. Removal of the generator from the
cradle assembly may cause excessive vibration and damage to the engine-
generator set.
DO NOT install and operate this generator in a small compartment., i.e.
generator compartments of vehicles, motor homes or travel trailers. These
compartments
will not allow enough free flow of fresh air to reach the engine generator set
for cooling and will cause the unit to overheat, damaging both the engine and
generator. Small compartments will also develop hot spots where there is very
little air flow and may cause a fire.
PLEASE NOTE There are 3rd party companies making enclosures for generators
that have been properly engineered. The use of these 3rd party enclosures is
acceptable as long as they have been engineered and meet applicable code.
DO NOT attempt to operate at 50 cycles. These units are designed and governed
to operate at 60 cycles only.
UNIT CAPABILITIES
GENERATOR CONNECTIONS
EC6010: 120 Volt and 240 Volt receptacles are provided for connection to
various loads. The following diagram represents this 5,160 watt (rated output)
generator. A &
B represent the 120 volt output legs of this generator. Up to 2,580 watts at
120 volts (43 Amps) can be drawn from the receptacles attached to either A or
B output legs. This generator is capable of producing 21.5 Amps of 240 volt
current at C. Check the appliance or tool nameplates for the current and
voltage to insure compatibility. Remember that power taken from C reduces the
power available equally at both A and B and vice versa.
STARTING ELECTRIC MOTORS
Electric motors require much more current (amps) to start them than to run
them. Some motors, particularly low cost split-phase motors, are very hard to
start and require 5 to 7 times as much starting current as running current.
Capacitor motors are easier to start and usually require 2 to 4 times as much
starting current as running current. Repulsion Induction motors are the
easiest to start and require only 1 1/2 to 2 1/2 times as much starting as
running current.
Most fractional horsepower motors take about the same amount of current to run
them whether they are Repulsion Induction (RI), Capacitor (Cap), or Split-
Phase (SP) type. The following chart shows the approximate current required to
start and run various types and sizes of 120 Volt 60 cycle electric motors
under average load conditions.
| STARTING AMPS
---|---
HP| Running Amps| Split Phase Motor| Capacitor Motor| Repulsion Induction
Motor
1/6| 3.2| 16 to 22| 6 to 13| 5 to 8
1/4| 4.5| 22 to 32| 9 to 18| 7 to 12
1/3| 5.2| 26 to 35| 10 to 21| 8 to 17
1/2| 7.2| Not Made| 14 to 29| 11 to 18
1| 13| Not Made| 26 to 52| 20 to 33
The figures given in the previous chart are for an average load such as a blower or fan. If the electric motor is connected to a hard starting load such as an air compressor, it will require more starting current. If it is connected to a light load, or no load such as a power saw, it will require less starting current. The exact requirement will also vary with the brand or design of the motor.
Self-exciting generators respond to severe overloading differently than utility power. When overloaded, the engine is not able to supply enough power to bring the electric motor up to operating speed. The generator responds with high initial starting current, but the engine speed drops sharply. The overload may stall the engine. If allowed to operate at very low speeds, the electric motor starting winding will burn out in a short time. The generator winding may also be damaged.
CAUTION: EQUIPMENT DAMAGE
Running the generator set under these conditions may result in damage to the
generator stator as well as the motor winding.
The heavy surge of current required for starting motors is required for only
an instant. The generator will not be damaged if it can bring the motor up to
speed in a few seconds of time. If difficulty is experienced in starting
motors, turn all other electrical loads off and if possible reduce the load on
the electric motor.
Motor starting capacity – 2HP code ‘G’ capacitor start engine.
Trying to start a larger motor or higher code motor, i.e. ‘J’ or ‘K’, may
result in damage to both the generator and the electric motor, especially 120
Volt motors.
LOAD TYPES
This generator is designed and rated for general commercial use. The running
watts rating assumes a variable load. If your application has a fixed load
that does not vary, an additional derate of 20% from the running watts is
recommended to ensure the longest useful life of the engine and generator end.
PREPARING THE UNIT
UNPACKING
- CAUTION: EQUIPMENT DAMAGE
Always check oil level prior to use. Failure to maintain the engine oil at the proper level will result in serious engine damage.
When you unpack your engine-generator set be sure to remove all the information sheets and manuals from the carton.
- As you receive your unit, it is critical to check it for any damage. If any damage is noted, it is always easiest to refuse the shipment and let WINCO take care of the freight claim. If you sign for the unit, the transfer of the ownership requires that you file the freight claim
- Before proceeding with the preparations of your new generator for operation, take a couple of minutes to ensure the unit you have received is the correct model and review the specification pages in this manual to ensure that this unit meets your job requirements.
COMPARTMENT INSTALLATION
When installing this generator in vehicle compartments it is essential that
proper care is taken to prevent overheating. The following guidelines will
help prevent these problems.
The easiest way to prevent overheating is to mount the generator on a slide
out tray. This will move the generator into open air whenever it is in
operation. A vertical opening door can also provide protection from rain
during operation.
If the generator must be installed in an enclosed compartment during operation
it is important to provide adequate cooling air flow.
This can cause air to recirculate and can result in generator overheating. The
windings will fail prematurely in this scenario. Separate air intakes for the
engine and generator can help reduce heat. The design should be tested with
measurements taken for engine oil temperature and the generator stator
windings. Contact WINCO for help in evaluating your application.
LUBRICATION
CAUTION: EQUIPMENT DAMAGE
Failure to maintain the engine oil at the proper level will result in serious
engine damage.
Before starting the engine, verify the crankcase is filled to the proper level with a good quality oil. The recommended grade oil and quantity of oil required is listed in the engine operator’s manual and under the service tab in this manual. This unit was shipped with oil in it. The engine normally holds 1.3 quarts (41.6 oz.) of oil. Use the dipstick to ensure that you have the proper oil level in the crankcase. The full oil level mark on the dipstick is depicted in the following image.
Oil is added to the engine by removing the oil cap and adding oil at this
point. After filling the crankcase to the proper level, be sure you properly
tighten the oil fill cap.
NOTE: This engine generator must be on a level surface before you check
or add oil to the system.
The necessity of using the correct oil and keeping the crankcase full cannot
be overemphasized. Engine failures resulting from inadequate or improper
lubricant are considered abuse and not covered by the generator or engine
manufacturer’s warranty.
OIL RECOMMENDATIONS
Outdoor temperatures determine the proper oil viscosity for the engines. Winco
recommends our 5W-30 fully synthetic oil to give you excellent protection in
cold temperatures while maintaining excellent performance in warmer weather.
DIESEL FUEL
Always use a good grade of # 2 diesel fuel. For cold weather, blended #1 fuel
may be used. Fuel cetane number should be 45 or higher and the fuel MUST be
low sulfur
or ultra low sulfur fuel. See engine operators manual for additional fuel
recommendations including Bio-Diesel fuel. Never use gasoline or gasohol.
Always ensure that the fuel is clean and free of all impurities. Always be
sure to keep the strainer in place when filling the fuel tank.
WARNING: FIRE DANGER
Diesel fuel is flammable and can be ignited, causing or enlarging fires when
proper precautions are not taken.
Never use fuel that has been stored for an extended period of time. Fuel will
lose its volatile properties and you will
be left with a ‘gum’ or varnish residue. This varnish-like substance will clog
the filters, fuel lines, and injectors. Old, contaminated, stale fuel will not
burn properly. The use of a fuel additive, such as Sta-Bil, or an equivalent
will minimize the formation of fuel gum deposits. If a unit has been out of
operation for an extended period of time, it is best to drain old fuel from
the engine and replace with fresh fuel before attempting to start.
BATTERY INSTALLATION
You will need to connect this unit to a battery to operate it. Cables have not
been provided as length are going to vary depending on your installation.
These engines are
all negative ground. The positive battery cable must be connected to the open
large terminal on the start solenoid (This terminal may have a small 16 GA.
wire on it for the charging circuit). The negative cable should be attached to
a good ground on the engine. This is usually one of the engine mounts.
Start Solenoid terminals
A twelve volt battery, rated at 300 CCA or larger is recommended for this
electric start generator set. Follow the battery manufacturer’s
recommendations for servicing and charging prior to use.
CAUTION: EQUIPMENT DAMAGE:
These electric start engines are NEGATIVE GROUND. Use extreme caution when
connecting the battery. Connect the NEGATIVE battery terminal to GROUND.
For your safety, always connect the positive battery cable to the “bat+” terminal first. Then connect the negative battery cable to the “Bat-” terminal. Make sure all connections are clean an tight. Reverse the sequence when disconnecting, disconnect the negative cable first. These engines produce enough direct current to keep the battery charged under normal operating conditions, but were not intended to be used as a battery charger.
WARNING: PERSONAL INJURY:
Lead acid batteries produce explosive hydrogen gas when charging. Keep sparks,
flames, and burning cigarettes away from the battery. Ventilate the area when
charging or using the battery in an enclosed space. Lead acid batteries
contain sulfuric acid, which causes severe burns. If acid contacts eyes, skin,
or clothing, flush well with water. For contact with the eyes, get immediate
medical attention.
CAUTION:
Do NOT open or mutilate the battery. Released electrolyte is known to be
harmful to the skin and eyes and to be very toxic.
A battery presents a risk of electrical shock and high short circuit current. The following precautions must be observed when working with batteries:
- Remove watches, rings and other metal objects.
- Use tools with insulated handles.
- Check both the battery cable ends and the battery posts to be sure they are free of corrosion.
- Always connect the battery positive first and then connect the battery negative cable. When removing the battery cables from the battery reverse the procedure, disconnect the negative cable first and then the positive cable.
- Be sure all connections are tight and coat the terminals and cable end with dialectic grease.
WARNING:
The electrolyte is diluted sulfuric acid that is harmful to the skin and eyes.
It is electrically conductive and corrosive. The following precautions must be
always be taken.
- Always wear full eye protection and protective clothing.
- Where electrolyte contacts skin, wash off immediately with water.
- If electrolyte contacts the eyes, flush thoroughly and immediately with water and seek immediate medical attention.
Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of one pound of bicarbonate of soda (baking soda) to one gallon of water. The bicarbonate of soda solution is to be added until the evidence of reaction, foaming, has ceased. The resulting liquid is to be flushed water and the area dried.
DANGER: EXPLOSIVE FIRE RISK
Never smoke when near batteries. Do not cause a flame or spark in the battery
area. Always discharge static electricity from your body before touching
batteries by first touching a ground metal surface.
SERVICING BATTERIES
Batteries used on these units may over time lose water. This is especially
true if you are using a trickle charger to maintain your battery. When
refilling the battery with water use only distilled water. Tap water will
shorten the service life of the battery.
Never fill the battery above the fill line. Overfilling above the upper level
line may cause the electrolyte to overflow, resulting in corrosion to the
engine or nearby parts. Immediately wash off any spilled electrolyte following
the procedure above.
Note: always make sure that a new battery is fully charged before installing
it on a generator set.
All connections must be clean and tight. Check the electrolyte (fluid) in the
battery periodically to be sure it is above the plates. Never allow the
battery to remain in a discharged condition.
BATTERY CHARGING
Units have a small flywheel charger built into the engine flywheel assembly
for recharging the starting battery. This flywheel charger generates a small
AC current that passes through a diode assembly to produce DC charging current
of about 1 to 3 Amps. This circuit is not designed to be used as a battery
charging circuit to recharge dead batteries.
CONTROL PANEL
The control panel can be installed on either side of the genend. Placement
will be determined on the installation of the unit.
- Snip off the zip ties around the wires that will be getting moved. Remove the front cover of the control panel. Locate the two bolts inside the panel that are securing the panel to the skid. Remove these two bolts. Make sure to keep track of all hardware being taken off and keep in an area where they won’t get lost.
- Remove the 4 screws around the top of the genend and remove the cover. There is a rubber grommet that secures the wires in place, gently remove it by pulling it down, keeping the wires through it.
- Place the panel on the other side of the generator (receptacle facing out). Secure the panel to the skid mount using the pre-installed rivet nuts.
- Replace the control cover. Push the rubber grommet with the wires through it, back onto the genend cover. Place the cover back on the genend with the grommet on the same side of the control panel. Secure the wires with new zip ties.
FUEL PUMP
Like the control panel, the fuel pump can also be placed on either side of the
generator.
- Snip the zip ties around wires/lines that will be moved. Detach the ground wires from the skid base (green wire) and in front of the engine (black wire). Locate the two bolts on the fuel pump mounting bracket.
- Carefully, to ensure diesel fuel does not leak, move the fuel pump to the other side of the unit. The fuel line will be longer than needed and will need to be shortened. Secure the fuel pump mounting bracket to the skid mount using the pre-installed rivet nuts.
- Reconnect the ground wires. The green wire connects to the skid base. There may already be a ground wire screwed down, add the green wire and re-secure the screw. The black, longer wire will connect to the front of the engine.
CONNECTING FUEL SUPPLY
Fuel Pump Specifications:
- Voltage 12
- PSI 9.0 to 11.5
- Amps 1.6 average
- Average Lift 6 feet
The fuel pump is self-priming and self-regulating.
Tank size, tank location, hose size, hose routing, and hot spots all play a role in a successful fuel tank installation. Preferred fuel installations use 1/4” hose that run straight to the engine with no drops or twists from an adequately sized fuel tank.
Connect a 1/4” fuel hose to the hose fitting located on the fuel pump. Use a hose clamp to secure the hose to the fitting.
Connect fuel line to the fuel source.
A 1/4” fuel return hose will connect to the T-fitting located above the engine.
Secure the return hose with a hose clamp. Connect the return line to the fuel source.
INITIAL START UP
The throttle control on these generators is preset and locked to operate at
3600 RPM (nominal) with no load speed set at 3690 RPM. Only a trained service
technician should be allowed to adjust this speed setting.
NOTICE: ENGINE START LOCKOUT
This unit will not start if it is low on oil. The lubricating oil level must
be at the full mark before the engine will start and run. This engine will not
start without a battery. The fuel shut-off solenoid requires 12V DC to
operate.
BASIC OPERATION
If the engine is cold and stiff or if the battery is not fully charged,
starting can be made easier by slowly hand cranking the engine through the
compression stroke before pushing the starter switch. This permits the starter
to gain momentum before the heavy load of the compression stroke occurs. This
minimizes the drain on the battery and improves the possibility of starting
under such adverse conditions. Always keep the battery charged, especially
during cold weather operation.
- Check oil level, refill as needed.
- Make sure the fuel solenoid valve lever is in the down position. This lever should never be put in the up position. The lever is located under the key switch as pictured. 3. Turn key to 1st position (Ref A). 4. Turn key to the 2nd position – starting (Ref B). 5. Return key to 1st position when engine is running (Ref A).
- NOTE: While the engine is running, all warning lights should be off except the OK light.
STARTING HINTS
-
COLD WEATHER
Use the proper oil for the temperature expected.
CAUTION: EQUIPMENT DAMAGE
Never use ether or any other starting aides. Serious engine damage or personal injury may result from ignoring this simple warning. -
HOT WEATHER
Use the proper oil for the temperature expected.
STOPPING
- Move the key to the “OFF” position.
- Make sure the fuel solenoid valve lever is in the down position. The lever is located under the key switch as pictured. The generator will not shutdown if this lever is in the up position. 3. Before extended storage (over 30 days) certain precautions must be taken to ensure the fuel doesn’t deteriorate and clog the fuel system. NOTE: Running the engine to use up the fuel in the lines, fuel pumps and injectors will still leave a small amount of fuel in the system. It is best extended storage to treat the fuel before draining.
- While the engine is warm, drain the oil and refill with fresh oil.
- Clean dirt and chaff from cylinder, cylinder head fins, blower housing, screen, and muffler areas.
- Store in a clean and dry area.
CONNECTING THE LOADS
The engine-generator covered in this manual was designed for portable use. Do
NOT operate indoors. The unit should be stored in a warm, dry location. Move
the unit outdoors to a flat, dry location for use.
WARNING: PERSONAL DANGER:
Operating any engine driven generator without proper air flow can result in
personal injury or death. DO NOT operate this unit inside a home or garage,
near vents or windows, or anywhere carbon monoxide gas could accumulate.
Failure to properly limit and balance the load applied to the generator will
cause the generator to produce low voltage and may damage the engine generator
set. It may also cause severe damage to the loads connected to the generator
at the time. Improper loading of the generator set constitutes abuse and will
not be covered by warranty.
A 30 Amp receptacle (NEMA L14-30) has been provided to allow the connection of
loads to the generator. This receptacle is a full load receptacle protected by
a 30 Amp hydraulic magnetic breaker. The breaker toggle switch is located on
the control panel, located next to the receptacle.
Your individual loads must be protected by individual circuit breakers mounted
in some type of distribution panel. This location will also be where you will
install your neutral
to ground bond. You must wire four separate wires from the generator (2-hot,
1- neutral, and 1-ground) to the distribution panel.
APPLYING THE LOADS
Allow the engine to warm up for two or three minutes before applying any load.
This will allow the engine to reach normal operating temperature and oil to
circulate throughout the engine. A short warm-up time will permit the engine
to work more efficiently when the load is applied and will reduce the wear in
the engine, extending its life. Receptacles have been provided to allow loads
to be connected to the generator.
The loads should be added one at a time. If a large motor is being started: or
multiple motors are being started, they should be started individually and the
largest should be started first.
CAUTION: EQUIPMENT OVERLOAD
Keep the generator load within in the generator and receptacle nameplate
rating. Overloading may cause damage to the generator and/or the loads.
Most electric tools and appliances will have the voltage and amperage
requirements on their individual nameplates. When in doubt, consult the
manufacturer or a local electrician. The nameplate amperage rating for
electric motors can be misleading. See “Starting Electric Motors” in the Unit
Capabilities.
This generator end is controlled by an AVR. The engine governor will
automatically adjust itself to the load. No harm to the generator will result
if it is operated with no load connected.
CAUTION: EQUIPMENT DAMAGE
Diesel engines should never be run for an extended period of time with a very
light load or no load on them, it may do permanent damage to the engine if run
under these conditions.
Proper utilization of the receptacles located on the control panel is necessary to prevent damage to either the receptacles or the generator. The generator is a limited source of electrical power, therefore, pay special attention to the receptacle and generator ratings. The nameplate rating can be obtained through a single receptacle as long as the receptacles amperage rating is not exceeded.
GROUNDING
Proper grounding of your generator is application dependent. Carefully
evaluate your planned use of your generator to understand which grounding you
require.
If you are not sure what to do, contact a competent professional to assist
you. The NFPA 70 250:34-35 are good technical references.
STANDARD PORTABLE GENERATOR
Your WINCO portable generator ships with a bonded neutral. You can safely use
this generator without external grounding as long as all loads are powered
through the receptacle panel.
VEHICLE-MOUNTED GENERATOR
Your WINCO portable generator ships with a bonded neutral. When mounted to a
vehicle to safely distribute power it is necessary that the generator frame is
bonded to the vehicle frame. The generator should only supply equipment that
is cord and plug connected through receptacles mounted on the generator or the
vehicle.
PERMANENTLY INSTALLED GENERATORS
This WINCO portable generator ships with a bonded neutral and overcurrent
protection. NFPA 70 refers to this as a “separately derived system.” When
connecting it to a building a transfer switch specifically designed for GFCI
and bonded neutral generators is required.
WIRING
Plug your tools such as drills, saws, blowers, sump pump, and other items to
be powered directly into the generator receptacles. Before plugging in all the
tools and cord
sets, recheck the rating of the generator set. Be sure it
can handle the intended load and is compatible with the voltage, phase, and
current ratings. ‘Hard wiring’ this unit directly into a temporary
construction site electrical system is NOT A SIMPLE DO-IT-YOURSELF JOB. For
your safety, all wiring must be done by a qualified electrician and conform to
the National Electric Code and comply with all state and local codes and
regulations. Check with local authorities before proceeding.
WARNING: PERSONAL DANGER
A fully isolated, double pole double throw manual transfer switch must be
installed any time a generator is being connected to an existing distribution
system.
- These engine-generator sets are designed for portable heavy duty commercial use. Receptacles are provided on the control panel to permit 120 and 240 Volt portable appliances and tools to be plugged directly into them. A 4-wire receptacle (two hot, one ground, and one neutral) has been provided on the control panel for use in temporary power applications requiring 120/240 Volt power.
- If the generator set is connected to an existing distribution system, a fully isolated manual transfer switch must be installed. The transfer switch prevents damage to the generator and the other circuit components if main line power is restored while the generator is connected. Installing a transfer switch also permits the use of normal fusing.
- Many homes and construction sites are wired for at least 60 to 100 Amp entrance service, much greater than the capacity of this portable generator. When installing the generator at these sites, a secondary emergency distribution panel may have to be installed. The emergency distribution panel must be installed by a licensed electrician according to all applicable codes. The electrician will move the critical circuits to be powered during the outage to the emergency panel. Keep in mind only a limited amount of amperage is available from the generator set. Some circuit breakers may still have to be turned off to prevent an overload on the generator during the initial start up. See the nameplate on your generator for the amperage \ capabilities of your unit.
CAUTION: EQUIPMENT DAMAGE
Failure to properly limit and balance the load applied to the generator will
cause the generator to produce low voltage and may damage the engine generator
set. It may also cause severe damage to the loads connected to the generator
at that time. Improper loading of the generator set constitutes abuse and will
not be covered by warranty.
YOURGEN
The WINCO YourGen meter allows you to see useful information about your
generator from the front panel
by displaying RPMs, Voltage, frequency, load, hours, and maintenance
reminders. It also has the ability to display warnings if any parameter gets
outside of normal operation range.
Cycle Button
During normal operation, the display will toggle through on fixed delay. If
you want to see any specific item, you can press the cycle button to move it
to that setting. Once the display is selected, the delay is approximately 5
seconds before it starts toggling. This button is also used to reset
maintenance reminders.
RPM
The meter will display the RPMs of the engine. This number is calculated based
upon frequency and is not directly measured from the engine. The engine-
generator must be run at the correct speed in order to produce the proper
electrical voltage and frequency.
CAUTION: EQUIPMENT DAMAGE
The output voltage should be checked to ensure the generator is working
properly prior to connecting a load to the generator. Failure to do so could
result in damage to equipment plugged into the unit and possible injury to the
individual.
Operating Speed
All engines have a tendency to slow down when a load
is applied. When the electrical load is connected to the generator, the engine
is more heavily loaded, and as a result, the speed drops slightly. This slight
decrease in speed, together with the voltage drop within the generator itself,
results in a slightly lower voltage when the generator is loaded to its full
capacity than when running no load. The slight variation in speed also affects
the frequency
of the output current. This frequency variation has no appreciable effect in
the operation of motors, lights, and most appliances. However, electronic
equipment and clocks will be affected if correct RPM is not maintained. See
Load vs. Output chart.
Although individual units and models vary slightly, the normal voltage and frequency of the engine-generator described in this manual are approximately as follows, under varying loads:
LOAD vs. OUTPUT
Generator Load| Speed (RPM)| Frequency (Hz)| Voltage
None| 3690| 61.5| 120V
Half| 3600| 60.0| 120V
Full| 3510| 58.5| 120V
The speed of the engine was carefully adjusted at the factory so that the generator produces the proper voltage and frequency. For normal usage, the speed setting should not be changed. If the generator is being run continuously on a very light load, it is often advisable to lower the operating speed slightly.
The engine will govern itself at full speed. Intentionally overriding the governor and operating the generator at low voltage may damage both the generator and any load connected to it. Running the engine at excessively high speeds results in high voltage, which may significantly shorten the life of light bulbs and appliances being used, as well as possibly damaging the engine.
CAUTION: EQUIPMENT DAMAGE
SPEED ADJUSTMENTS SHOULD ONLY BE MADE BY A QUALIFIED SERVICE TECH. Whenever
making any speed adjustments, check the YourGen meter and be sure the voltage
and speed are correct.
Output voltage should be checked periodically to ensure continued proper operation of the generating plant and appliances.
-
Hz
This is the measured frequency of the generator set. See the table in the RPM section above for an explanation of voltage and frequency ranges under load. -
V1
Output voltage of Line 1 (L1 on panel) to neutral. See the Load vs. Output table for an explanation of voltage and frequency ranges under load. -
V2
Output voltage of Line 2 (L2 on panel) to neutral. See the Load vs. Output table for an explanation of voltage and frequency ranges under load. -
V1-V2
Output voltage of Line 1 (L1) and Line 2 (L2). See the Load vs. Output table for an explanation of voltage and frequency ranges under load. -
Hours
This displays the total running hours of the generator set. When the generator is turned off, the hours will remain displayed. The display is run on a CR2032, ten-year battery. Once the unit is running, the battery connected to the unit will then supply the power to the YourGen meter. -
Load Bars
These bars indicate how much load is being used on Line 1 (L1) and Line 2 (L2).
It is good practice to monitor the YourGen Meter when applying load. This will ensure the generator is balanced.
120 Volt and 240 Volt receptacles are provided for connection to various loads.
The following diagram represents this 5,160 watt (rated output) generator. A & B represent the 120 volt output legs of this generator. Up to 2,580 watts at 120 volts (43 Amps) can be drawn from the receptacles attached to either A or B output legs. This generator is capable of producing 21.5 Amps of 240 volt current at C. Check the appliance or tool nameplates for the current and voltage to insure compatibility. Remember that power taken from C reduces the power available equally at both A and B and vice versa.
Change Oil Warning –
After the first 50 hours, the engine oil should be changed. The YourGen meter
will light up the oil icon ( ) and the word ‘change’ will flash. Once the oil
has been changed, press and hold the cycle button for approximately 5 seconds
until the warning has been removed from the display to reset the warning. The
meter will then remind you of oil changes on the appropriate schedule for your
generator. It is important to remember that the engine manufacturer recommends
changing the oil on a calendar schedule even if the total number of
operational hours have not been reached. Certain operating environments may
also require more frequent oil changes.
Alarms –
The display will start blinking and toggle to the first parameter that is out
of specification. The panel will remain flashing until the fault condition
returns to within the acceptable range, see following table.
| Acceptable Range
---|---
Frequency| 57-63 Hz
Voltage| 110VAC-130VAC
VAC1-VAC2| 220VAC-260VAC
Battery –
When the unit is off, the YourGen meter will display the hours continuously
using a coin cell back-up battery inside the meter. Once the unit is running,
the meter will get power from the main unit battery.
- Voltage 3.0V DC
- Battery Type CR2032
- Lifetime 10 Years
The battery has a 10 year lifetime, in the event you need to change the battery, follow these instructions:
-
The battery is located in the control box near potentially live AC terminals. To prevent electrocution while changing the battery disable the unit by disconnecting the main battery and then open the receptacle panel. Locate the backside of the YourGen meter. Gently pry the back plate off using the slot located on top.
-
Once open, the battery will be located at the top.
Using a needle nose plier, carefully pull out the battery. -
Replace the battery having the POSITIVE (+) side Using a needle nose plier, carefully pull out the battery.
-
Replace the battery having the POSITIVE (+) side down. Ensure the battery is secured between the battery connections.
-
Replace the back plate of the meter and close the receptacle panel using the screws to secure it. Reconnect the unit’s main battery.
ENGINE CARE
MAINTENANCE SCHEDULE
| Daily or Every 10 hrs| Every 250* hrs| Every 500** hrs
---|---|---|---
Check Oil| ✔| |
Check oil filter| ✔| |
Check dry air cleaner| ✔| |
Fuel tank cleaning| | | ✔
Clean cooling fins| | | ✔
Replace engine oil| | ✔|
Replace oil filter| | ✔|
Replace fuel filter| | | ✔
Set and clean injectors| | | ✔
Rocker arm adjustment| | | ✔
-
- If engine use is infrequent; every year
- ** If engine use is infrequent; every 2 years
If you are using oil of a quality lower than the recommended one then you will
have to replace it every 150 hours
If major engine service or repair is required, contact an authorized engine
service center. The manufacturer of these engines has established an excellent
world-wide engine service organization. Engine service is very likely
available from a nearby authorized dealer or distributor.
CHANGING THE OIL
Change the oil after the first 50 hours of operation and yearly or 250 hours
thereafter under normal operating conditions.
Outdoor temperatures determine the proper oil viscosity for the engines. Winco recommends our 5W-30 fully synthetic oil to give you excellent protection in cold temperatures while maintaining excellent performance in warmer weather.
- Change oil while the engine is still warm, the oil will flow more freely.
- Push in the yellow adapter slightly and turn to the left, unlocking the oil drain. Drain the oil into an approved container.
- Replace the adapter by pushing in and turning to the right to lock .
- Remove oil fill cap.
- Fill to correct level with oil. Reinstall cap.
- Remove the oil filter and dispose of it properly. NOTE: This engine requires 41.6 oz. (1.3 qts) of oil if it is completely drained. Use caution when refilling the engine as some residual oil may have remained in the engine. Always use the dipstick when filling the engine with oil to prevent overfilling.
- Replace oil filter and filter plug.
- Start the engine and warm it up.
- After warming up the engine, recheck the oil level and refill as necessary to bring it to the proper level.
CHECKING THE OIL LEVEL
The oil level must always be checked before the engine is started. Take care
to remove any dirt or debris from around the oil plug before removing. Be sure
the oil level is maintained. Fill to the “FULL” mark on the dipstick.
AIR FILTER
Clean the filtering element with air blast. Air must be blown from inside to
outside the cartridge at a distance of at least 6 inches from the paper.
Lightly and repeatedly tap the element on a hard surface to eliminate all
excess dirt.
WARNING: EQUIPMENT DAMAGE
Never start or run the engine with the air filter removed.
- Remove the cover.
- Remove the wing nut.
- Remove the filter element.
- Check the rubber seal is undamaged.
- To loosen debris, gently tap the air filter on a hard surface. If the air filter is excessively dirty replace with a new filter. You can use pressurized air (not to exceed 30 psi) to clean the filter. Always blow the compressed air from inside to the outside.
- Clean the dirt from the inside of the air cleaner body and cover. Reinstall the filter in housing. Tighten the wing nut securely.
- Install and secure the cover.
- Remove and clean the pre-filter if clogged.
GENERATOR CARE
Proper care and maintenance of the generator is necessary to ensure a long
trouble free life.
EXERCISING THE GENERATOR
The generator should be operated every three to four weeks. It should be
operated for a period of time sufficient to warm the unit up and to dry out
any moisture that has accumulated in the windings. If left, this moisture can
cause corrosion in the winding. Frequent operation of the engine-generator set
will also ensure that the set is operating properly should it be needed in an
emergency.
GENERATOR MAINTENANCE
Any major generator service, including the installation or replacement of
parts, should be performed only by a qualified electrical service technician.
USE ONLY FACTORY APPROVED REPAIR PARTS.
- Bearing – The bearing used in these generators is a heavy duty, double sealed ball bearing. They require no maintenance or lubrication.
- Receptacles – Quality receptacles have been utilized. If a receptacle should become cracked or otherwise damaged, replace it. Using damaged or cracked receptacles can be both dangerous to the operator and destructive to the equipment.
CLEANING
Remove dirt and debris with a cloth or brush. DO NOT use high pressure spray
to clean either the engine or the generator. The high pressure spray could
contaminate the fuel system and the generator components.
- Keep the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling. At least yearly, remove the blower housing on the engine and clean the chaff and dirt out of the engine cooling fins and fly wheel. Clean more often if necessary. Failure to keep these areas clean may cause overheating and permanent damage to the unit.
- Periodically clean muffler area to remove all grass, dirt, and combustible debris to prevent a fire.
- On engine mufflers equipped with spark arresters, the spark arrester must be removed every 50 hours for cleaning and inspection. Replace if damaged.
TROUBLESHOOTING
Problem | Possible Causes |
---|---|
Won’t start | Low oil level Out of fuel |
Start switch in OFF position Fuel Valve turned off Plugged fuel filter
Blown fuse in key switch
Battery required to open solenoid
Voltage too low| Engine speed is too low Generator overloaded Defective stator
Defective rotor (field) Defective AVR
Circuit breaker trips| Defective load Defective receptacle Excessive load
GFCI type of load i.e. a building with bonded neutral
Voltage too high| Engine speed is too high
Generator overheating| Overloaded Insufficient ventilation
No output voltage| Short in load (disconnect)
Tripped or defective circuit breaker Broken or loose wire
Defective receptacle
No residual magnetism (in generator)
Defective stator Defective rotor (field) Shorted capacitor Shorted diodes on rotor GFCI receptacle tripped
Will not shutdown| Fuel solenoid valve lever is in up position
CONTROL PANEL WIRING DIAGRAM
WINCO warrants to the original purchaser for 24 months that goods manufactured
or supplied by it will be free from defects in workmanship and material,
provided such goods are installed, operated and maintained in accordance with
WINCO written instructions and applicable codes.
WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this
warranty, shall be limited to the repair of the product. At WINCO’s option,
material found to be defective in material or workmanship under normal use and
service will be repaired or replaced. For warranty service, return the product
within the warranty period, to your nearest WINCO Authorized Service Center or
to WINCO in Le Center Minnesota.
Duration Consumer, Commercial and Rental Parts & Labor: 24 Months
Parts Only: 24 Months
EXCLUSIONS:
- Normal maintenance consumables or labor.
- This warranty does not cover travel time, mileage or labor for removal or re-installation of WINCO product from its application.
- Normal wear and tear.
- Costs of rental equipment.
- WINCO does not warrant engines. Engines are covered exclusively by the warranties of their respective manufacturers.
- WINCO does not warrant component parts that are warranted by their respective manufacturers.
- WINCO does not warrant modifications or alterations which were not made by WINCO.
- WINCO does not warrant products which have been subjected to misuse and/or negligence or have been involved in an accident. Proof of proper maintenance must be furnished upon request.
THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE
NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, OR OTHERWISE CREATED, INCLUDING BUT
NOT LIMITED TO WARRANTIES OF MERCHANTABILITY, OR WARRANTIES OF FITNESS FOR A
PARTICULAR PURPOSE.
WINCO is liable for the repair or replacement of the product only and is not
liable for incidental or consequential damages as permitted by your state.
This warranty gives you specific legal rights which may vary from state to
state.
CALIFORNIA EVAPORATIVE EMISSION CONTROL **
**
WARRANTY STATEMENT
YOUR WARRANTY RIGHTS AND OBLIGATIONS
The California Air Resources Board is pleased to explain the evaporative
emission control system’s warranty on your model 2020 generator. In
California, new equipment that uses small off-road engines must be designed,
built, and equipped
to meet the State’s stringent anti-smog standards. WINCO must warrant the
evaporative emission control system on your generator for the period listed
below provided there has been no abuse, neglect or improper maintenance of
your equipment leading to the failure of the evaporative emission control
system.
Your evaporative emission control system may include parts such as:
carburetor, fuel tank, fuel cap, fuel lines (for liquid fuel and fuel vapors),
fuel line fittings, fuel line clamps, carbon canisters, and carbon canister
mounting brackets.
MANUFACTURER’S WARRANTY COVERAGE
The evaporative emission control system is warranted for two years. If any
evaporative emission related parts on your equipment are defective, the parts
will be repaired or replaced by WINCO.
WINCO INC. • 225 S. CORDOVA AVE • LE CENTER, M20 N 56057 • 507-357-6821
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>