Product Information
The product is a microwave oven with the model number 11196830-02. It is designed for installation in a base unit or tall unit. The dimensions of the installation are given in millimeters. The microwave oven comes with a cable and plug for electrical connection.
Product Usage Instructions
- Ensure that there is adequate ventilation to the front of the appliance during installation. Do not obstruct the air vents with any objects.
- If installing in a tall unit, use the handle cut-outs on the side of the casing to lift the appliance instead of lifting it by the door handle to avoid damage.
- Follow the provided installation dimensions to correctly position and install the microwave oven in either a base unit or tall unit.
- For tall unit installation, connect the appliance according to the provided instructions, ensuring that there are no connections permitted in certain areas.
- For base unit installation, connect the appliance according to the provided instructions, ensuring that there are no connections permitted in certain areas.
- Before using the microwave oven, it must be built-in and properly installed. Slide the appliance into the niche and feed the cable with the plug through the back of the unit.
- Position the appliance and open the door. Secure the appliance onto the side walls of the unit using the screws provided.
- Ensure that the appliance has not been damaged before connecting it to the electrical supply. Never use a faulty appliance.
- Connect the appliance directly to a suitable power supply using the original cable. Do not use an extension lead, multi-socket plug adapter, or energy-saving devices.
- Comply with local regulations for the electrical installation.
Installation
When installing the microwave oven, ensure that there is adequate ventilation to the front of the appliance. Do not obstruct the air vents with any objects. Lifting the microwave oven by the door handle could cause damage to the door. Use the handle cut-outs on the side of the casing to lift the appliance.
Installation dimensions
Dimensions are given in mm.
Tall unit installation
Base unit installation
Side view
- Glass
- Stainless steel
Tall unit connection
- Front view
- Mains connection cable, length = 1600 mm
- No connections permitted in this area
Base unit connection
- Front view
- Mains connection cable, Length = 1600 mm
- No connections permitted in this area
Carrying out installation
The microwave oven must be built in before it can be used.
- Slide the microwave oven into the niche. Feed the cable with the plug through the back of the unit.
- Position the appliance.
- Open the appliance door and secure the appliance onto the side walls of the unit using the screws provided.
Electrical connection
Risk of injury caused by a faulty appliance. Before connecting the appliance, ensure that it has not been damaged in any way. Never use a faulty appliance. The appliance is supplied ready for connection with a cable and plug. Ensure that the protective contact socket is easily accessible at all times. If that is not possible, ensure that a suitable means of disconnection is provided on the installation side for each pole. fire hazard due to overheating. Connecting the appliance to a multi-socket plug adapter or to an extension lead can overload the cable. The appliance must not be used with so-called energy-saving devices. These reduce the amount of energy supplied to the appliance, causing it to overheat. For safety reasons, do not use an extension lead or multi-socket plug adapter. Connect the appliance directly to the power supply using the original cable and do not use any intermediate elements. The electrical installation must comply with local regulations. If the connection cable is damaged, it must only be replaced with a specific connection cable of the same type (available from your Miele dealer). For safety reasons, such replacement may only be carried out by a qualified technician or your Miele dealer. The necessary connection data can be found on the data plate located on the front of the oven interior or on the back of the appliance. Compare the specifications on the data plate with those of the electricity supply. Make sure that they match. If in any doubt, consult a qualified electrician. Temporary or permanent operation on an autonomous power supply system or a power supply system that is not synchronised with the mains power supply (e.g. island networks, back-up systems) is possible. A prerequisite for operation is that the power supply system complies with the specifications of EN 50160 or an equivalent standard. The function and operation of the protective measures provided in the domestic electrical installation and in this Miele product must also be maintained in isolated operation or in operation that is not synchronised with the mains power supply, or these measures must be replaced by equivalent measures in the installation. As described, for example, in the current version of VDE-AR-E 2510-2.