GE current LEDL098 LED Refit Solutions Glass Tubes Installation Guide

June 12, 2024
GE current

GE current LEDL098 LED Refit Solutions Glass Tubes

GE current LEDL098 LED Refit Solutions Glass Tubes-
product

Product Information: Type C LED Tube with remote Driver

The Type C LED Tube with remote Driver is a lighting solution designed for use with 36W Drivers LED36T8/G/8/830, LED36T8/G/8/835, LED36T8/G/8/840, and LED36T8/G/8/850. It is suitable for both one-tube and two-tube fixtures. The LED tube offers
energy-efficient lighting and can be dimmed using a compatible dimming controller. The product comes with a comprehensive installation guide and is backed by the manufacturer’s customer support.

Product Usage Instructions

  1. Before starting the installation process, ensure that the power to the unit is turned off. Follow proper Lock Out and Tag Out procedures.

  2. Remove the existing lamps, fixture coverplate, and ballast. Replace lampholders if necessary. Leave the wiring in place and ensure that the wire length is long enough to attach to the new LED driver. Verify that the AC supply line is provided with a ground
    wire connected to the luminaire.

  3. Secure the LED driver to the fixture by using the existing ballast mounting holes and screws. If necessary, create new mounting holes using self-tapping screws (not provided).

    1. For one-tube fixtures:
    • Connect the black (L) and white (N) wires of the driver to the black and white wires of the AC line, respectively.
    • Connect the blue wire of the driver to the lampholder at one end.
    • At the opposite end, connect the red wire of the driver to the lampholder.
    • Cap the remaining blue wire.
  4. For two-tube fixtures:

  * Connect the black (L) and white (N) wires of the driver to the black and white wires of the AC line, respectively.
  * Connect the blue wires of the driver to lampholders at one end.
  * At the opposite end, connect the red wire of the driver to one lampholder.
  1. If you have a dimming option, connect the pink (formerly gray) and purple wires from the driver to the dimming controller. Make sure to refer to the dimming controller’s instructions for proper connection.
  2. Compact the wires and reattach the fixture coverplate.
  3. Affix the label provided with the product to the fixture where it can easily be noted.
  4. Insert the Type C LED tube into the lampholder of the fixture and rotate if necessary. Repeat this step for any remaining tubes.
  5. Restore power and ensure that the lamps are operating correctly.

Note: For any maintenance or lamp replacement needs, contact a qualified electrician or the manufacturer’s customer support at 1-800-327-0097. Order any replacement parts with the exact same model number.

BEFORE YOU BEGIN
Read these instructions completely and carefully.

Save these instructions

These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to be met with respect to installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purpose, the matter should be referred to Current. Current does not claim liability for any installation not performed according to this guide or not by a qualified electrician.

For Your Safety

Read and observe all CAUTIONS and WARNINGS shown throughout these instructions.
Installation to be performed by trained or qualified personnel. Ensure this manual is provided to the installers and users. Use this product only in the manner intended by the manufacturer. If there are any questions or concerns, contact the manufacturer. The product is designed for indoor application only, and should not be used in environment of high temperature and high humidity. Type C LED tubes & drivers are sold separately. Do not operate Type C LED tubes without the corresponding LED driver. The product is not intended for use with Emergency exits. Suitable for dry or damp location. Suitable for “Type IC” or “Type non-IC” luminaires. Max. 2 pcs LED tubes can be operated in a luminaire with minimum socket spacing of 5.5 inches apart.

Maintenance/Lamp Replacement
Contact a qualified electrician for maintenance service. Order any replacement parts individually with the exact same model number. For any questions or concerns contact the manufacturer at 1-800-327-0097.

WARNING
RISK OF FIRE OR ELECTRIC SHOCK – Disconnect power before installation or maintenance. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors. THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.

CAUTION

RISK OF INJURY

  • Tube may fall down if not installed properly, follow installation instructions.

  • Wear safety glasses and proper aid during installation and maintenance.
    RISK OF PRODUCT DAMAGE

  • Do not replace conventional LFL directly with Type C LED tubes. Type C LED tubes need a DC voltage to work.

  • More than one power supply present.

FCC

This Class A device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. This device complies with CAN ICES-005A.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

TYPE C LAMP – Intended for operation in luminaires with traditional fluorescent-type lampholders wired to an integral LED driver. This includes both factory-wired luminaires as well as those converted for this purpose under a retrofit program.

Provided Components
The components have been properly packed to avoid damage during transit. Inspect the components to confirm there is no physical damage. Do not install damaged components.

Parts List

  • LED Tube
  • LED Driver
  • Installation Guide
  • Label (affix to luminaire)

Tools Required

  • Screwdriver
  • Wire stripper/cutter
  • UL listed wire connectors

Installation Instructions

  1. Ensure that the power to the unit is turned off. Use proper Lock-Out and Tag Out procedure.

  2. Remove existing lamps, fixture cover plate, and ballast. Replace lamp holders if necessary. Leave wiring in place and make sure wire length is long enough to attach to the new LED driver. Verify that the AC supply line is provided with a ground wire connected to the luminaire.

  3. Secure LED driver to the fixture by using existing ballast mounting holes and screws. Use self-tapping screws (not provided) to create new mounting holes if necessary.
    GE current LEDL098 LED Refit Solutions Glass Tubes-
fig1

  4. 4A. One Tube Fixture: Connect the black (L) and white (N) wires of driver to black and white wires of AC line, respectively. Connect the blue wire of the driver to the lampholder at one end. At the opposite end connect the red wire of the driver to the lampholder. Cap remaining blue wire.
    4B. Two Tube Fixture: Connect the black Ill and white IN) wires of driver to black and white wires of AC line, respectively. Connect blue wires of the driver to lamp holders at one end. At the opposite end connect the red wire of the driver to one lampholder.
    GE current LEDL098 LED Refit Solutions Glass Tubes-
fig2

  5. Dimming option: Connect the pink (formerly gray) and purple wires from the driver to the dimming controller.
    NOTE: Other wires not shown for clarity.
    GE current LEDL098 LED Refit Solutions Glass Tubes-
fig3

  6. Compact wires and reattach fixture cover plate.

  7. Affix the label to the fixture where it can easily be noted.

  8. Insert the Type C LED tube into the lampholder of the fixture and rotate if necessary. Repeat for remaining tubes.

  9. Restore power and ensure lamps are operating correctly.
    GE current LEDL098 LED Refit Solutions Glass Tubes-
fig4

www.LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GE current User Manuals

Related Manuals