Product Information

Product Name Sentinel Rack
Product Type ONLINE Rack
Installation Plug & Play
Connectivity USB Plug
Applications DIGITAL LIVING, E-MEDICAL, EMERGENCY, INDUSTRY
VA Range 1500-3000 VA (Models available in 1500 VA and 3000 VA)
Highlights Provides increased efficiency and greater configuration

options. Maximum expandability with USB port and expansion slot for
protocol conversion or relay contacts boards. Energy-saving
shut-off switch to reduce energy consumption during inactivity.
Available in 1500 VA and 3000 VA models.
Battery Optimization| The Sentinel Rack range has a deep discharge protection device
to optimize battery life. It performs periodic battery efficiency
tests and has a wide input voltage tolerance range to reduce
battery usage and maintain performance over time.
Runtime Expandability| Optional battery extension packs can be connected to increase
UPS runtime. SER 3000 ER version is designed without internal
batteries and has more powerful battery chargers for longer
runtimes.
Noise Level| Less than 40 dBA, thanks to high frequency components and
load-based fan speed control.
Warranty| 2-Year Warranty
Options| SOFTWARE: PowerShield3, PowerNetGuard
ACCESSORIES: NETMAN 208, MULTICOM 302, MULTICOM 352, MULTICOM 372,
MULTICOM 384, MULTI I/O, MULTIPANEL, Manual Bypass 16 A Rack
BATTERY CABINET

Product Usage Instructions:

To use the Sentinel Rack, follow these instructions:

  1. Ensure plug & play installation by connecting the UPS to the power source.
  2. Connect the UPS to your device using the USB plug.
  3. Select the appropriate application mode (DIGITAL LIVING, E-MEDICAL, EMERGENCY, INDUSTRY).
  4. For increased efficiency and configuration options, utilize the USB port and expansion slot for protocol conversion or relay contacts boards.
  5. If the UPS will be inactive for prolonged periods, use the shut-off switch to reduce energy consumption to zero (ECO LINE).
  6. Monitor the battery optimization feature, which includes deep discharge protection and periodic battery efficiency tests. You can manually activate the battery efficiency test if needed.
  7. If longer UPS runtime is required, connect optional battery extension packs. For SER 3000 ER version, which does not have internal batteries, use more powerful battery chargers for extended runtimes.
  8. Take advantage of the low noise level by ensuring the UPS is placed in a suitable location.
  9. Refer to the user manual for software options and accessories that can enhance the functionality of the Sentinel Rack.
  10. In case of any issues or errors, refer to the warranty terms for support and contact Riello UPS for assistance.

Sentinel Rack has compact design and improved performance developed by the Riello UPS research and development team. Sentinel Rack uses ON LINE double conversion technology, resulting in the highest levels of reliability and maximum protection for critical loads such as servers and IT and voice/data applications. For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using the 3000 VA model fitted with more powerful battery charger. The front display panel has been entirely redesigned, adding an LCD display that shows the input and output voltages, battery readings and UPS operating status information. The inverter and the microprocessor control stage provide increased efficiency and greater configuration options.
Maximum expandability: the Sentinel Rack is supplied as standard with a USB port and an expansion slot for protocol conversion or relay contacts boards. With energy savings in mind, Sentinel Rack is also fitted with a shut-off switch to reduce energy consumption to zero during prolonged periods of inactivity (ECO LINE). Sentinel Rack is available in 1500 VA and 3000 VA models.

OPERATING FLEXIBILITY

Different operating modes are available to reduce energy consumption based on specific load and user requirements.

  • ON LINE: maximum load protection and output voltage waveform quality;
  • ECO Mode: the UPS uses LINE INTERACTIVE technology, with the load powered by the mains, reducing consumption and thus improving efficiency (up to 98%);
  • SMART ACTIVE Mode: the UPS automatically selects ON LINE or LINE INTERACTIVE operation, depending on the quality of the mains supply, checking the number, frequency and type of disturbances present;
  • STANDBY OFF: the UPS supplies the load only when the mains fails. The inverter begins working with a progressive start up sequence to prevent inrush currents;
  • Frequency Converter operation (50 or 60 Hz).

EMERGENCY FUNCTION

This configuration ensures the operation of emergency systems that must be supplied in the event of a mains power failure, such as emergency lighting, fire detection/extinguishing systems and alarms. When the mains power supply fails, the inverter begins powering the loads with a progressive start up (Soft Start) in order to prevent overload. Sentinel Rack is compliant for installation in medium-voltage transformer rooms in accordance with applicable legislation, for the power supply with reserve charge of medium-voltage coils.

BATTERY OPTIMISATION

The Sentinel Rack range has a deep discharge protection device to optimise battery life.
Periodically the UPS carries out a battery efficiency test (which can also be manually activated); its wide input voltage tolerance range helps to reduce battery usage and maintain performance over time.

RUNTIME EXPANDABILITY (SER 3000) Optional battery extension packs can be connected to increase UPS runtime. SER 3000 ER version is designed without internal batteries and a more powerful battery chargers to achieve longer runtimes.

LOW NOISE LEVEL
Thanks to the use of high frequency components and load-based fan speed control, the noise produced by the UPS is less than 40 dBA.

FEATURES

  • Filtered, stabilised and reliable voltage: double conversion ON LINE technology (VFI compliant with IEC 62040-3) with filters for the suppression of atmospheric disturbances;
  • High overload capability (up to 150%);
  • Programmable Auto-restart when mains is restored;
  • Battery start up (Cold Start);
  • Power factor correction (UPS input power factor, close to 1);
  • Wide input voltage tolerance range (from 140 V to 276 V) without battery intervention.
  • Runtime extendable up to several hours;
  • Fully configurable using UPS Tools configuration software;
  •  Highly reliable batteries (automatic and manually-activated battery test);
  • High level of UPS reliability (total microprocessor control);
  • Low impact on the mains (sinusoidal take up).

ADVANCED COMMUNICATIONS

  • Multi-platform communication for all operating systems and network environments: PowerShield3 supervision and shutdown software for Windows operating systems 11, 10, 8, Server 2022, 2019, 2016 and previous versions, Windows Server Virtualization Hyper-V, macOS, Linux, Citrix XenServer and other Unix operating systems;
  • UPS Tools configuration and customisation software supplied as standard;
  • RS232 serial port and opto-isolated contacts;
  • USB port;
  • Slot for communications boards.

2-YEAR WARRANTY

OPTIONS

Riello UPS-1500-VA-Rackmount-UPS-Systems-4

BATTERY CABINET

DETAILS

Riello UPS-1500-VA-Rackmount-UPS-Systems-3

MODELS   SER 1500 SER 3000 ER
POWER   1500 VA/1350 W 3000 VA/2700 W
INPUT    
Rated voltage [V] 220 / 230 / 240

Voltage range without

battery intervention [V]

| 140 <Vin <276 @ 50% load / 184 <Vin <276 @ 100% load
Voltage tolerance [V]|  | 230| ±20%
Maximum permitted voltage [V]|  | 30| 0
Rated frequency [Hz]|  | 50 /| 60
Frequency tollerance [Hz]| 50 ±5% / 60 ±5%
Power factor|  | >0.| 99
Current distortion|  | ≤7%|
BYPASS|  |  |
Voltage tolerance [V]|  | 180 /| 264
Frequency tolerance [Hz]| Frequency selected (from ±1.5 to ±5 configurable)
Overload times| 125% for 5 s, 150% for 1 s
OUTPUT|  |  |
Voltage distortion with linear load / with non-linear load|  | <2% /| <4%
Frequency [Hz]| Selectable: 50 or 60 or self-learning
Static variation|  | ±1%|
Dynamic variation| ≤5% in 20 ms
Waveform|  | Sinuso| idal
Current crest factor|  | 3:| 1
Efficiency ECO and SMART

ACTIVE Modes

|  | 98%|
BATTERIES
Type| VRLA AGM maintenance-free lead based
Recharge time|  | 2-4| h
OVERALL SPECIFICATIONS|  |  |
Net weight [kg]|  | 22| 14 (without batteries)
Gross weight [kg]|  | 24| 18
Dimensions (WxDxH) [mm]| 450x380x87 (19”x380x2U)
Packaging dimensions (WxDxH) [mm]| 540x490x190
Protection against overvoltage [J]|  | 30| 0
Protections| Overcurrent – short circuit – overvoltage – undervoltage – temperature – excessive low battery
Communications| USB / DB9 with RS232 and contacts / Slot for communications interface
Input plugs|  | 1x IEC 320 C14 (10 A)| 1x IEC 320 C20 (16 A)
Output sockets|  | 8x IEC 320 C13 (10 A)| 8x IEC 320 C13 (10 A) + 1x IEC 320 C19 (16 A)

Standards

| European directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant

Classification in accordance with IEC 62040-3 (Voltage Frequency Indipendent) VFI – SS – 111

Ambient temperature for the UPS| 0 °C – +40 °C
Recommended temperature for battery life| +20 °C – +25 °C
Range of relative humidity| 5-95% non-condensing
Colour|  | RAL| 9005
Noise level at 1 m (ECO Mode) [dBA]|  | <4| 0
Standard equipment

provided

| Power cable, IEC-IEC cable, USB cable, safety manual, quick start guide

RPS SpA – Riello Power Solutions – Member of the Riello Elettronica Group Viale Europa, 7 – 37045 Legnago (Verona) – ITALY – Tel: +39 0442 635811
www.riello-ups.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals