BOSYTRO 80A Solar Charge Controller with DC User Manual

June 12, 2024
BOSYTRO

BOSYTRO 80A Solar Charge Controller with DC

BOSYTRO-80A-Solar-Charge-Controller-with-DC-product

Solar Controller User Manual

Safe use Advice

  1. The controller can only be used for photovoltaic panels charging. Do not use DC or other power sources as charging sources.
  2. The controller is only suitable for all kinds of lead-acid batteries (including openings, seals, gels, etc.). Do not use it for other batteries such as lithium batteries or nickel metal hydride batteries.
  3. Install the controller close to the battery to avoid voltage drop caused by too long wires and affect normal voltage identification.
  4. The controller automatically identifies 12V/24V battery. When installing for the first time, ensure that the battery has enough voltage so that the controller can identify the correct battery type.
  5. Install the controller on a flat, well-ventilated surface.

Features

  • Industrial grade main control chip and high-quality materials for environmental protection and high use efficiency.
  • Large screen LED display with adjustable charging and discharging parameters and power-off memory function.
  • Complete 3-stage charge management.
  • Intelligent protection including built-in overcurrent protection, short circuit protection, reverse polarity protection, and open protection.
  • Dual USB output with 5V maximum current of 3A, supporting Apple mobile phone charging.
  • Double MOSFET reverse current protection to reduce heat generation failure rate.
  • Equipped with a timer and light sensor for solar lighting system.

Keystroke

  • MENU : Switch between different displays and enter/exit settings by long press.
  • UP : Press to increase value. –
  • DOWN : Press to decrease value.

BOSYTRO-80A-Solar-Charge-Controller-with-DC \(1\)

Display interface/parameters

BOSYTRO-80A-Solar-Charge-Controller-with-DC \(2\)

Note: 1. Main interface: press down to turn on/off load alone.

  • 2. 3 load working modes:
    • 24H load normally open mode
    • 1-23H light control + 1-23H timing off mode
    • OH pure light control mode

Fault guide

Anomalies Possible causes Solution

Full sun but not

charging

| Photovoltaic panels open or

reversed

| Reconnect PV panel
Load mark not bright| Mode setting error| Resetting
Battery voltage too low| Afresh Recharge
Load logo flashes slowly| load overcurrent| reduce load power
Load mark fast flash| Short circuit protection| Remove short circuit, Automatic

recovery

Controller not light| Battery voltage too

low/reverse connection

| Replace battery/check reverse

connection

---|---|---

Technical reference

  • Equalization:
    • Sealed Battery: 14.4V
    • Gel Battery: 14.2V
    • Flood Battery : 14.6V

Note : Connect the charge controller to the battery first, then the solar panel, and finally the load. Connect in strict order to avoid damaging the controller. The disassembly sequence should be opposite to the wiring sequence

Specifications

  • 12V battery and 18V solar panel
  • 24V battery with 36V solar panel
  • Not applicable:
  • Lithium battery, NiMH batteryBOSYTRO-80A-Solar-Charge-Controller-with-DC \(3\) BOSYTRO-80A-Solar-Charge-Controller-with-DC \(4\)

Note:
Charge controller should connect battery first, then solar panel, finally the load!Please connect in strict order, otherwise controller may damaged, disassembly sequence is opposite to the wiring sequence.