Honeywell 51863 Carnegie Ceiling Fan User Manual

June 12, 2024
Honeywell

Carnegie Ceiling Fan
User Manual
Read and save these instructions before use

Honeywell 51863 Carnegie Ceiling Fan **Model

51863**

PACKAGE CONTENTS

Honeywell 51863 Carnegie Ceiling Fan - PACKAGE
CONTENTS

HARDWARE CONTENTS

Honeywell 51863 Carnegie Ceiling Fan - HARDWARE
CONTENTS Note: Some extra hardware may be included. The quantity listed above is the number required for installation.

THANK YOU
Honeywell Ceiling Fans feature a collection of fans in various sizes and specifications to ensure your choice of indoor or outdoor fan delivers optimum performance for your room’s size. You can trust the quality of Honeywell Ceiling Fans to deliver  maximum  airflow and stylish lighting options. Honeywell Ceiling Fans use high-quality materials that are long lasting and durable to deliver a great look and last for years to come.

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product.

  • Before you begin installing the fan, disconnect the power by removing fuses or turning off the circuit breakers.
  • Make sure all electrical connections comply with local codes, ordinances, the National Electrical Code and ANSI/NFPA 70-199. Hire an electrician or consult a do-it-yourself handbook if you are unfamiliar with installing electrical wiring.
  • Make sure the installation site you choose allows a minimum of 7 feet from the blades to the floor and at least 30 inches from the tip of the blades to any obstruction.
  • The weight of the fan is 20.08 pounds.

DANGER: When using an existing outlet box, make sure it is securely attached to the building structure and can support the full weight of the fan. Failure to this can result in serious injury or death. The stability of the outlet box is essential in minimizing  wobble and noise in the fan after installation is complete.
WARNING: Using a full-range dimmer switch to control fan speed will cause a humming sound from the fan. To reduce the risk of fire or electric shock, do NOT use a full-range dimmer switch to control fan speed.
WARNING: To reduce the risk of fire, electric shock or personal injury, mount the fan to an outlet box marked “ACCEPTABLE FOR FAN SUPPORT” and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt. Secure the outlet box directly to the building structure. The outlet box and its support must be able to support the moving weight of the fan (at least 35 lbs.).
WARNING: To reduce the risk of fire, electric shock or personal injury, wire connectors provided with this fan are designed to accept only one 12-gauge house wire and two lead wires from the fan. If your house wire is larger than 12-gauge and/or there is more than one house wire to connect to the two fan lead wires, consult an electrician for the proper size wire connectors to use.
WARNING: To reduce the risk of fire, electric shock or personal injury, do not bend the blade arms when installing them, balancing the blades or cleaning the fan. Do not insert objects between the rotating fan blades.
WARNING: To reduce the risk of personal injury, use only parts provided with this fan. The use of parts other than those provided with this fan will void the warranty.
CAUTION: Be sure the outlet box is properly grounded or a ground (green or bare) wire is present.
CAUTION: Carefully check all screws, bolts, and nuts on the fan assembly ensure they are secured.
CAUTION: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device (if applicable).

CAN ICES-003 (B) / NMB-003 (B)
CAN ICES-005 (B) / NMB-005 (B)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause  ndesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
–Reorient or relocate the receiving antenna.
–Increase the separation between the equipment and receiver
–Connect the equipment into and outlet on a circuit different from that to which the receiver is connected.
–Consult the dealer or an experienced radio/TV technician for help.
Please note changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
HKC-US
3350 Players Club Parkway #225
Memphis, TN 38125
1-877-361-3883

CARE AND MAINTENANCE

At least twice each year, lower the canopy to check the downrod assembly and tighten all screws on the fan. Clean the motor housing and blades with a soft brush or lint-free cloth to avoid scratching the finish.
Bulb Replacement: Use 40-watt max. B11, E26-base LED, CFL or incandescent bulbs. Halogen bulbs are not recommended for this item.
Battery Replacement : Use CR2032 lithium batteries. Exhausted batteries should be removed from remote. Non-rechargeable batteries should not be recharged. Do not dispose of batteries in fire, as they may explode.
Important: Shut off the main power supply before you begin any maintenance task. Do NOT use water or a damp cloth to clean the fan.

PREPARATION

Before beginning the assembly of this product, ensure all parts are present. Compare all parts with the package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.
Estimated assembly time: 2 hours
Tools required (not included): Electrical tape, Phillips Screwdriver, Safety Glasses, Step Ladder, and Wire Strippers.

  1. Turn off power to the fan at the breaker box and the wall switch (Figure 1.1). DANGER: Failure to disconnect the power supply prior to installation may result in serious injury or death.

  2. Choose one of the following mounting options (Figure 1.2) :
    Standard Mount – best suited for ceilings 8 feet or higher. For very high ceilings, use a longer downrod (not included).
    Angle Mount – best suited for angled or vaulted ceilings. A longer downrod is sometimes necessary to ensure proper blade clearance. Ensure the ceiling angle is not steeper than 10 degrees.
    Flushmount Installation – not available for this model.
    Closemount Installation – not available for this model.

  3. Choose a suitable location – Ensure the blades will be at least 30 inches from any obstructions. Also check the downrod length to ensure the blades will be at least 7 feet above the floor (Figure 1.3).

Honeywell 51863 Carnegie Ceiling Fan - obstructions

INITIAL INSTALLATION

  1. Loosen all four mounting bracket screws and completely remove the two screws from the round holes in the canopy. Then remove mounting bracket from the canopy and save the screws for later (Figure 2.1).

  2. Install the mounting bracket to the outlet box (not included) using the screws and washers provided with the outlet box.
    WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to the outlet box marked “acceptable for fan
    support” and use the mounting screws and washers provided with the outlet box (Figure 2.2).

  3. Remove the 10 motor screws from the underside of the motor assembly and save for blade arm assembly (Figure 2.3).

Honeywell 51863 Carnegie Ceiling Fan - INSTALLATION

STANDARD OR ANGLE MOUNT INSTRUCTIONS

  1. Remove the downrod pin and downrod clip from the downrod. Then partially loosen the set screws in the yoke at the top of the motor assembly (Figure 3.1).
  2. Insert the downrod through the canopy and yoke cover. Feed the wires and braided cable from the fan through the downrod (Figure 3.2).
  3. Slide the downrod into the yoke of the motor assembly. Align holes and reinstall the downrod pin and downrod clip and secure with the two set screws (Figure 3.3).
  4. Install the ball end of the downrod into the opening of the mounting bracket. Rotate the downrod until the tab in the mounting bracket is seated in the slot in the downrod ball (Figure 3.4). WARNING: The fan and/or downrod should not rotate in the mounting bracket, if installed correctly. Failure to align the slot in the downrod ball with the tab on the mounting bracket may result in fan falling causing serious injury or death.
  5. Insert the receiver, antenna first, into the mounting bracket with the flat side facing the ceiling.
    Note: The receiver will rest directly on top of the downrod. (Figure 3.5).

Honeywell 51863 Carnegie Ceiling Fan - ANGLE MOUNT

SECONDARY HANGING SYSTEM INSTRUCTIONS

For installation in the United States: Building codes in the U.S.A. do not require installation of a Secondary Hanging System.
If desired, the braided cable can be cut and removed using wire cutters (sold separately). Skip to FINAL INSTALLATION.
For installation in Canada : In compliance with building codes in Canada, installation of the Secondary Hanging System is required.

  1. Feed the loop of the braided cable, preassembled to the motor assembly, up through the outlet box mounted in the ceiling (Figure 4.1).

  2. Install secondary support screw, spring washer and support washer partly into the side of the brace installed in the ceiling.
    Then loop the braided cable up and over the ceiling brace and place the open loop of the braided cable around the secondary support screw. Note: The ceiling support brace may not be accessible from below. If not, it must be accessed from above.
    Important: The braided cable must make a complete circle around the support brace to secure the fan (Figure 4.2).

  3. Tighten the secondary support screw, securing the braided cable (Figure 4.3).

Honeywell 51863 Carnegie Ceiling Fan - Tighten

FINAL INSTALLATION

  1. Secure all wiring connections together with wire connector from hardware bag and the wire connectors from remote pack according to the diagram and these steps (Figure 5.1):
    • Connect the green wires from the downrod and mounting bracket to the bare/green (ground) supply wire.
    • Connect the Blue wire (FOR LIGHT) from the receiver to the Blue fan wire.
    • Connect the Black wire (TO MOTOR L) from the receiver to the Black fan wire.
    • Connect the White wire (TO MOTOR N) from the receiver to the White fan wire.
    • Connect the Red wire (AC IN L) from the receiver to the Black (hot/power) supply wire.
    • Connect the White (AC IN N) from the receiver to the White (neutral) supply wire.
    Important: After the connections have been made, the connected wires should be turned upward and pushed carefully up into the outlet box. Place the black and white wire connections on opposite sides of the outlet box.

  2. Align the canopy over the loosened mounting bracket screws. Place the J-slot of the canopy onto the mounting bracket screws and rotate clockwise (Figure 5.2).

  3. Secure the canopy with the two previously removed mounting bracket screws. Tighten all the mounting bracket screws securely (Figure 5.3).Honeywell 51863 Carnegie Ceiling Fan - mounting

  4. Partially insert three blade screws through the blade arm, blade, and into the medallion. Tighten each blade screw starting with the one in the middle. Repeat this step for the remaining blades (Figura 5.4).

  5. Install the blade arms to the underside of the motor assembly using the ten previously removed motor screws (Figure 5.5).

  6. Remove one of the three fitter plate screws preassembled to the fitter plate and loosen the other two but do not remove.
    Feed the 9-pin connector through the center hole in the light pan. Align the keyhole slots in the light pan with the loosened screws in the fitter plate. Turn light pan clockwise and replace the previously removed fitter plate screw. Tighten all screws.
    (Figure 5.6).

  7. Remove one of the three light pan screws from the light pan and loosen the other two but do not remove. Connect the 9-pin connector from the light pan to the 9-pin connector from the light kit. Lift the two keyhole slots in the light kit over the two loosened light pan screws and turn in a clockwise direction. Then, use the previously removed light pan screw to secure the light kit to the light pan. Tighten all screws (Figure 5.7).

  8. Install the E26-base LED bulbs into the sockets of the light kit. Important: Make sure you allow the bulbs and light kit to cool before you replace the bulbs. (Figure 5.8).

  9. If desired, the wall bracket in remote pack can be installed to a wall using the provided mounting screws. The remote can be stored in the mounting bracket for easy access (Figure 5.9).

Turn on power to fan at breaker box and the wall switch. Assembly is complete.

Honeywell 51863 Carnegie Ceiling Fan - Assembly

OPERATING INSTRUCTIONS

  1. Remove the battery door from the back of the remote using a flat-head screwdriver (not included). Insert the two CR2032 batteries into the remote; ensure the positive pole of the batteries face up (as pictured) and then replace the battery door (Figure 6.1).

  2. To operate the fan using the remote, press and release the following buttons (Figure 6.2):
    Fan Off – Turns the power to fan off.
    High Speed – Turns on fan at high speed.
    Medium Speed – Turns on fan at medium speed.
    Low Speed – Turns on fan at low speed.
    Light Control : Turns the light on and off. Press and hold to dim or brighten lights (for dimmable bulbs only).
    Light Delay Off mode – Light stays on for 60 seconds to allow for safe exit from room. Tap Light Delay once to activate. Fan light blinks once to confirm Light Delay is active. Press any button to cancel.
    Variable Breeze – Simulates a breeze in nature. Press and hold button to activate. Press any fan speed button to cancel.
    Home Shield™ – Simulates occupancy while away from home. Fan remains off and the light randomly turns on for a minimum of five minutes and a maximum of 20 minutes. The light remains off for 60 minutes between events. Press and hold button to activate. Light will blink twice to confirm Home Shield is active. Press any button to cancel.
    LED Indicator – should illuminate when any remote button is pressed. If not, replace the DC3V, CR2032 batteries.
    LEARN Button – Syncs remote to receiver (see TROUBLESHOOTING for instructions). Note: To access LEARN button, remove battery door from back of the remote using a flat-head screwdriver.

  3. Using a ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort (Figure 6.3).
    In warmer weathe r, push the reverse switch left, which will result in downward airflow creating a wind chill effect.
    In cooler weather , push the reverse switch right and the fan to low, which will result in upward airflow that can help move stagnant, hot air off the ceiling area.
    Important: Wait for the fan to stop before moving the reverse switch located on the light kit. The reverse switch must be set either completely left or right in order for the fan to function correctly. If the reverse switch is set in the middle position, the fan will not operate.

Honeywell 51863 Carnegie Ceiling Fan - operate

TROUBLESHOOTING

If you experience any faults, please check the Troubleshooting section below. If a problem cannot be remedied or you are experiencing difficulty in installation, please contact Customer Service: 1-877-361-3883, Monday – Friday, 8am – 5pm, Central.
Warning: Shut off the power supply before you begin any maintenance task.

PROBLEM CORRECTIVE ACTION
The fan does not move. 1. Firmly push the reverse switch completely left or

right.
2.Make sure the wall switch is turned on.
3.Turn the power on or check the fuse (breaker).
4.Turn the power off and check all connections at the ceiling outlet box.
The fan is noisy.| 1.Check and tighten all screws that hold the fan blades to the blade arms and the motor.
2.Replace the cracked blade.
3.Do not use a full range dimmer switch to control the fan speed.
4.Ensure the outlet box is secured to the building structure.
5.Ensure the mounting bracket is secured to the outlet box and that the screws are tight.
The fan wobbles excessively.| 1.Check and tighten all screws that hold the fan blades to the blade arms and the blade arms to the motor.
2.Switch one blade with a blade from the opposite side, or balance the fan using the blade balancing kit.
3.Turn off the power. Loosen the canopy and verify that the mounting bracket is secure to the electrical outlet box. The bracket must be flush without movement against the outlet box. Verify the outlet box is secure.
4.Use a longer downrod (sold separately) or move the fan to another location.
5.Lift up the yoke cover and tighten the set screws on the yoke until secure.
The fan operates
correctly but the lights pre not working.| 1.Ensure the 9-pin connectors are properly secured.
2.Turn the power off and check all connections at the ceiling outlet box.
Remote control does not work.| 1.Power surge may have cleared the memory and remote needs to be resynced to the receiver. Syncing Instructions: Turn off the main power, then turn it back on. Within 30 seconds, press and hold the HIGH SPEED and LOW SPEED buttons (or the ‘LEARN” button, located in the battery compartment) for 5 seconds. Fan will turn on at low speed and light off. This confirms the syncing process is successful.
2.Insert new CR2032 batteries in battery compartment of the wall control.
3.If there are several remote fans in proximity, turn the power off to those fans and re-sync the fan.

LIMITED LIFETIME WARRANTY

Set forth below, the manufacturer, Hong Kong China Electric Appliance Company (HKC) warrants the fan motor for this ceiling fan to be free from defects in workmanship and material for the life of the product. Also, subject to the limitations below, HKC warrants all ceiling fan parts (“ceiling fan parts” excludes the motor and parts made in whole or in part with glass) to be free from defects in workmanship and material for a period of one year after the date of purchase by the original purchaser at retail.
All claims must be made by the original purchaser, whether such purchaser purchased the product through a store or contractor. Ceiling fan part defects must be reported within the first year from the date of purchase. Parts made in whole or in part with glass and the finishes of metal and other surfaces are not warranted.
Purchasers are responsible for all costs of removing and reinstalling the product. Any damage to any part caused by ordinary wear and tear, accident, misuse, or improper installation, is not covered by this warranty. HKC assumes no responsibility whatsoever for fan installation. Any service performed by a non-licensed electrician will render the warranty invalid.
HKC’s sole responsibility shall be to repair or replace the motor, parts, or product within the terms stated above. HKC shall not be liable for any loss or damage of any kind, including any incidental or consequential damages resulting directly or indirectly,  from any breach of warranty, express or implied, or any other failure of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you.
If the original purchaser ceases to own the fan, this warranty is voided.
Should the purchaser encounter a problem with your fan related to defects in workmanship or materials within the warranty period associated with the defective part, HKC agrees to replace the defective part without charge, or at its option, to replace the ceiling fan with a comparable or superior model.
HKC’s warranties are limited to the written warranties set out in this HKC ceiling fan limited lifetime warranty. All other express and implied warranties, including, without limitation, the implied warranty of fitness for a particular purpose and the implied warranty of merchantability are disclaimed. Some states do not allow the disclaimer of implied warranties, so this disclaimer may not apply to you.

REPLACEMENT PARTS LIST

For replacement parts, call our customer service department 1-877-361-3883. Monday-Friday, 8am – 5pm, Central Time. Honeywell 51863 Carnegie Ceiling Fan - PARTS
LIST

51863

A Light Kit 44000024570
B Blade Arm (x5) 44074710001
C Blade (x5) 44086400001
D Medallion (x5) 44074720001
E Remote Pack 44000024910
HW Hardware Bag 44000024590

The Honeywell Trademark is used under license from Honeywell International Inc.
Honeywell International Inc. makes no representations or warranties with respect to this product.

This product is manufactured by
Hong Kong China Electric Appliance, LTD.
3350 Players Club Parkway, Suite 225
Memphis, TN 38125
1877-361-3883
9852 • 020923

Documents / Resources

| Honeywell 51863 Carnegie Ceiling Fan [pdf] User Manual
51863, 51863 Carnegie Ceiling Fan, 51863 Ceiling Fan, Carnegie Ceiling Fan, Carnegie, Carnegie Fan, Ceiling Fan, Fan
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals