hansgrohe 72469000 Rebris E Bathtub Faucet Instructions
- June 12, 2024
- hansgrohe
Table of Contents
Instructions for use
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing ,hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
- Prior to installation, inspect the product for transport damages. After it has been installed, no transport or surface damage will be honoured.
- The pipes and the fixture must be installed, flushed and tested as per the applicable standards.
- The plumbing codes applicable in the respective countries must be observed.
Technical Data
Operating pressure: | max. 1 MPa |
---|---|
Recommended operating pressure: | 0,1 – 0,5 MPa |
Test pressure: | 1,6 MPa |
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:| max. 60°C
Thermal disinfection:| 70°C / 4 min
- Safety against backflow
- The product is exclusively designed for drinking water!
Symbol description
**| Do not use silicone containing acetic acid!
Adjustment (see page 38)To adjust the hot water limiter. Using a hot
water limiter in combination with a continuous flow water heater is not
recommended.
---|---
**| Maintenance (see page 46)
- The check valves must be checked regularly according to EN 806-5 in accordance with national or regional regulations (at least once a year).
**| Dimensions (see page 40)
Flow diagram (see page 41)
free flow
**| Spare parts (see page 42)XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
340 = Brushed Black Chrome
400 = White/Chrome Plated
670 = Matt Black
700 = Matt White
990 = Polished Gold-Optic
**| Special accessories** (see page 42)order as an extra
• extension 25 mm #13595000
• Extension Set 22 mm (when wall is not deep enough) #15597XXX, #13597000,
13593XXX
| Cleaning (see page 39)
| Operation (see page 41)
| Test certificate (see page 48)
Fault| Cause| Remedy
---|---|---
Mixer stiff| – Cartridge defective, calcified| – Exchange cartridge
Mixer dripping| – Cartridge defective| – Exchange cartridge
Diverter not operating| – Residue| – Clean converter / grease O-rings
– Water pressure to low| – Increase water pressure
– Diverter defective| – Exchange diverter
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.| – Hot water limiter incorrectly set| – Set hot water limiter
– Crossflow| – Exchange cartridge
| Assembly (see page 35)
---|---
|
---|---
|
www.hansgrohe.com/cleaning-recommendation
http://www.hansgrohe.com/cleaning-recommendation
Cleaning recommendation / Warranty / Contact
|
---|---
|
|
|
P-IX DVGW SINTEF
15447XXX PA-IX 38298/IDB
31451000
31466000 PA-IX 38298/IDB BN0685
31487000 PA-IX 38298/IDB
31946000 PA-IX 38298/IDB
32477000 PA-IX 38298/IDB BN0685
32546XXX
71046000
71407000 PA-IX 38298/IDB
71474XXX PA-IX 38298/IDB
72406000 PA-IX 38298/IDB
74546000
71467XXX PA-IX 38298/IDB
71469XXX PA-IX 38298/IDB
75416XXX PA-IX 38298/IDB DM0707
76416XXX PA-IX 38298/IDB BN0685
72467XXX PA-IX 38298/IDB DN0343
72469XXX PA-IX 38298/IDB DN0343
Hansgrohe SE
DIN 4109-1
PA-IX 38298/IDB Hansgrohe · Auestraße 5 – 9 · D-77761 Schiltach · Telefon +49
(0) 78 36/51-1282 · Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com ·
Internet: www.hansgrohe.com
09/2022
9.06054.04
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>