BRESSER 7002512 Weather Center WTW 5in1 Instruction Manual
- June 12, 2024
- BRESSER
Table of Contents
- 7002512 Weather Center WTW 5in1
- GENERAL WARNINGS
- PARTS OVERVIEW
- Remote sensor single parts
- LCD DISPLAY
- BEFORE YOU START
- POWER SUPPLY
- INSTALLATION
- ALARM CLOCK SETTING
- WEATHER FORECAST
- TEMPERATURE & HUMIDITY
- RAINFALL
- WIRELESS SIGNAL RECEPTION
- TROUBLESHOOTING
- SPECIFICATIONS
- WARRANTY & SERVICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Weather Center WTW 5in1
Art. No. 7002512
INSTRUCTION MANUAL
7002512 Weather Center WTW 5in1
ABOUT THIS INSTRUCTION MANUAL
These operating instructions are to be considered a component of the device.
Please read the safety instructions and the operating instructions carefully
before use.
Keep these instructions for renewed use at a later date. When the device is
sold or given to someone else, the instruction manual must be provided to the
new owner/user of the product.
This product is intended only for private use. It was developed as an
electronic medium for the use of multimedia services.
GENERAL WARNINGS
RISK OF CHOKING!
Keep packaging material, like plastic bags and rubber bands, out of the reach
of children, as these materials pose a choking hazard.
RISK OF ELECTRIC SHOCK!
This device contains electronic components that operate via a power source
(batteries). Children should only use the device under adult supervision.
Only use the device as described in the manual; otherwise, you run the risk of
an electric shock.
RISK OF CHEMICAL BURN!!
Leaking battery acid can lead to chemical burns. Avoid contact of battery acid
with skin, eyes and mucous membranes. In the event of contact, rinse the
affected region immediately with a plenty of water and seek medical attention.
RISK OF FIRE/EXPLOSION!
Use only the recommended batteries. Do not short-circuit the device or
batteries, or throw them into a fire. Excessive heat or improper handling
could trigger a short-circuit, a fire or an explosion.
NOTE!
Do not disassemble the device. In the event of a defect, please contact your
dealer. The dealer will contact the Service Centre and can send the device in
to be repaired, if necessary.
Do not immerse the unit in water.
Protect the device from severe shocks!
Use only the recommended batteries. Always replace weak or empty batteries
with a new, complete set of batteries at full capacity. Do not use batteries
from different brands or with different capacities. Remove the batteries from
the unit if it has not been used for a long time.
The manufacturer is not liable for damage related to improperly installed
batteries!
SCOPE OF DELIVERY (FIG. 1)
Main unit (A), table stand for main unit (B), remote sensor (C), mounting
material, instruction manual
Required batteries:
6 pieces of Mignon batteries (1.5V, type AA)
PARTS OVERVIEW
Main unit (Fig. 2)
1. SNOOZE / LIGHT button
2. HISTORY button
3. MAX/MIN button
4. button
5. button
6. button
7. INDEX-Taste
8. button
9. button
10. button| 11. button
12. button
13. °C/°F slide switch
14. RCC button
15. SCAN button
16. RESET knob
17. Battery compartment
18. Alert LED indicator
19. LCD display with backlight
20. Table stand
---|---
Remote sensor (Fig. 3)
21. Rain collector (Sinkhole)
22. Circular level
23. Antenna
24. Wind cups
25. Mounting pole
26. Radiation shield| 27. Wind vane
28. Mounting base
29. Mounting claim
30. Red LED indicator
31. RESET button
32. Battery door
33. Mounting screws
---|---
Remote sensor single parts
Rain gauge (Fig. 4)
34. Rain collector (Sinkhole)
35. Tipping bucket| 36. Rain sensor
37. Drain holes
---|---
Temperature and humidity sensor (Fig. 5)
38. Radiation shield/protection
39. Sensor casing (Temperature and humidity sensor)
Wind sensor (Fig. 6)
40. Wind cups (Anemometer) | 41. Wind vane |
---|
LCD DISPLAY
Time / Calendar / Moon phases (Fig. 7)
1. MAX/MIN/PREVIOUS DATA indicator
2. Low battery indicator for main unit
3. Time
4. Ice pre-alert on
5. RC Signal strength indicator
6. Daylight saving time (DST) icon| 7. Moon phase
8. Day of the week
9. Alarm icon
10. Date
11. Month
---|---
Indoor temperature and humidity (Fig. 8)
12. Comfort/cold/hot icon
13. Indoor indicator
14. Indoor humidity| 15. HI / LO Alert and alarm on
16. Indoor temperature
---|---
Outdoor temperature and humidity (Fig. 9)
17. Outdoor signal strength indicator
18. Outdoor indicator
19. Outdoor humidity| 20. HI / LO Alert and alarm on
21. Outdoor temperature
22. Low battery indicator for sensor
---|---
12-hour weather forecast (Fig. 10)
23. Weather forecast indicator | 24. Weather forecast icon |
---|
Barometer (Fig. 11)
25. Barometer indicator
26. Histogram
27. ABSOLUTE/RELATIVE pressure indicator| 28. Barometer measurement unit
(hPa / inHg / mmHg)
29. Barometer reading
30. Hourly records indicator
---|---
Rainfall (Fig. 12)
31. Rainfall indicator
32. Time range record indicator
33. Day records indicator
34. Histogram| 35. HI Alert and alarm on
36. Current rainfall rate
37. Rainfall unit (in / mm)
---|---
Wind direction / wind speed (Fig. 13)
38. Wind direction indicator
39. Wind direction indicator(s) during last hour
40. Current wind direction indicator
41. Wind speed indicator
42. Wind levels and indicator| 43. Beaufort scale reading
44. Current wind direction reading
45. Average/Gust wind indicator
46. Wind speed unit (mph / m/s / km/h / knot)
47. Hi Alert and Alarm
---|---
Wind chill/ Heat index/ Indoor dewpoint (Fig. 14)
48. Wind chill/ Heat index/ Indoor dewpoint indicator
49. Wind chill/ Heat index/ Indoor dewpoint reading
BEFORE YOU START
IMPORTANT!
- Insert batteries for the main unit before doing so for the remote sensor.
- Place the main unit as close as possible to the remote unit.
- Position the remote unit and main unit within the effective transmission range.
When changing batteries always change batteries in the main unit as well as
all remote units and replace them in the correct order, so the remote
connection can be re-established. If batteries are exchanged in only one of
the devices (i.e. the remote sensor) the signal can’t be received or can’t be
received correctly.
Note, that the effective range is vastly affected by building materials and
position of the main and remote units. Due to external influences (various RC
devices and other sources of interference), the maximum distance can be
greatly reduced. In such cases we suggest to position the main unit and the
remote sensor at other places. Sometimes all it takes is a relocation of one
of these components of a few inches!
POWER SUPPLY
Main unit (Fig. 15)
- Open the battery compartment door.
- Install 3 batteries (AA size 1.5V) strictly according to the polarities shown.
- Reinsert the battery compartment door.
- Once the batteries are inserted, all the segments of the LCD will be shown briefly before entering the radio-controlled time reception mode.
- The RC clock will automatically start scanning for the radio-controlled time signal in 8 seconds.
NOTE!
- If no display appears on the LCD after inserting the batteries, press the RESET knob by using a pointed object.
- In some cases, you may not receive the signal immediately due to the atmospheric disturbance.
Remote sensor (Fig. 16)
- Open the battery compartment door.
- Install 3 batteries (AA size 1.5V) strictly according to the polarities shown.
- Reinsert the battery compartment door.
NOTE!
- Ensure the water tight O-ring is properly aligned in place to ensure water resistant.
- The red LED will begin flashing every 12 seconds.
Low battery warning
When it is time to replace the batteries, the respective low battery indicator
will be shown near to the time display (batteries for main unit) or near to
the outdoor temperature (batteries for remote sensor).
INSTALLATION
Remote sensor (Fig. 17-20)
Install the wireless 5-in-1 sensor in an open location with no obstructions
above and around the sensor for accurate rain and wind measurement.
Install the sensor with the smaller end facing the North to properly orient
the wind direction vane.
Add the rubber pads to the rubber pads as shown. Secure the mounting stand and
bracket (included) to a post or pole, and allow minimum 1.5m off the ground.
Fig. 17/18:
Fig. 19:
Fig. 20:| Mounting on pole (Pole Diameter 1″ – 1.3″ (25 – 33mm)).
Mounting on the railing.
Circular level.
---|---
Mounting guidelines:
- Install the wireless 5-in-1 sensor at least 1.5m off the ground for better and more accurate wind measurements.
- Choose an open area within 150 meters from the LCD display Main Unit.
- Install the wireless 5-in-1 sensor as level as possible to achieve accurate rain and wind measurements. A circular level device is provided to ensure a level installation.
- Mount the wireless 5-in-1 sensor with the wind meter end pointing to the North to correctly orient direction of the wind vane.
Main station (Fig. 21)
The unit is designed for desktop or wall mount for easy viewing.
Insert the stand so that the pins on the bottom side reach into the indentions
of the station.
The triangular notch on the backside of the main station can be used to mount
the device on walls with a wall screw (not included).
RECEIVING MEASUREMENTS AND TIME SIGNAL
Once batteries are placed in the remote unit, it will start transmitting
temperature readings at roughly 45 second intervals. As soon as batteries are
installed in the main unit it will start searching for a signal from the
remote sensor for about 3 minutes. Upon successful reception of the signal,
the outdoor temperature will be displayed on the main unit. The main unit will
automatically update its readings at about 45 second intervals.
Subsequently, the main unit will attempt to receive the DCF radio signal.
The reception symbol flashes. When the time signal is received after 3-5
minutes, the current time and date appear in the display. The reception symbol
will now be shown permanently in the display. Date and time are automatically
updated daily at 2:05 o’clock (CET) by the main unit.
Manual pairing after battery change
Whenever you changed the batteries of the wireless 5-in-1 sensor, pairing must be done manually.
- Change the batteries to new ones.
- Press and hold the SCAN button for 2 seconds.
- Press the RESET button on the sensor.
NOTE!
- Pressing RESET button at bottom of wireless 5-in-1 sensor will generate a new code for pairing purpose.
- Always dispose old batteries in an environmental safe manner.
DATA CLEARING
During installation of the wireless 5-in-1 sensor, the sensors were likely to
be triggered, resulting in erroneous rainfall and wind measurements.
After the installation user may clear all the erroneous data from the main
unit without a need to reset the clock and re-establish pairing.
Simply press and hold the HISTORY button for 10 seconds. This will clear out
any data recorded before.
TIME SETTING
The unit automatically set itself accordingly to the Radio Controlled Clock
signal it received. To set the clock/calendar manually, first disable the
reception by holding the RCC button for 8 seconds.
Manual time setting
- Press and hold button for 2 seconds until “12 or 24Hr” flashes.
- Use or button to adjust and press button to proceed to the next setting.
- Repeat step 2 for setting hours, minutes, seconds, year, month, date, hour offset, language and daylight saving time (DST).
NOTE!
- The unit will automatically exit setting mode if no button was pressed in 60 seconds.
- The hour offset is for DCF and MSF version. Its range is between -23 and +23 hours.
- The language options are English (EN), French (FR), German (DE), Spanish (ES), and Italian (IT).
- DST (Daylight Saving Time) feature is set to Auto (factory set). The clock has been programmed to automatically switch when the daylight saving time is in effect. User can set the DST to OFF to disable the feature.
Disable / Enable RCC signal reception (Fig. 12)
- Press and hold RCC button 8 seconds to disable the reception.
- Press and hold RCC button 8 seconds to enable automatic RCC reception.
ALARM CLOCK SETTING
Turn on/off alarm clock (and ice-alert function) (Fig. 13)
- Press button to show the alarm time.
- Press button twice to activate the alarm.
- Press button three times to activate alarm with ice-alert function.
- To disable the alarm, press button until the alarm icons disappear.
NOTE!
- Press SNOOZE/LIGHT button when alarm sounds to interrupt the alarm. The alarm will then start again after 5 minutes.
- Pres button when alarm sounds to deactivate the alarm until next time.
Alarm time setting
-
Press and hold button for 2 seconds to enter alarm setting mode.
Hours will begin to flash. -
Use or button to adjust the desired value and press button to proceed to set minutes.
-
Repeat step 2 to set minutes, then press button to exit.
NOTE!
Press button twice when alarm time is being displayed will activate the
temperature-adjusted pre-alarm (ice-alert). The alarm will sound 30 minutes
earlier if it detects outside temperature is below -3°C.
WEATHER FORECAST
The device contains sensitive pressure sensor built-in with sophisticated and proven software that predicts weather for the next 12 hours.
NOTE!
- The accuracy of a general pressure-based weather forecast is about 70% to 75%.
- The weather forecast is meant for the next 12 hours, it may not necessarily reflect the current situation.
- The “Snowy” weather forecast is not based on the atmospheric pressure, but based on the outdoor temperature. When the outdoor temperature is below -3°C (26°F), the “Snowy” weather indicator will be displayed on the LCD.
- The icon will flash on the screen when the rainstorm comes.
BAROMETRIC / ATMOSPHERIC PRESSURE
Atmospheric Pressure is the pressure at any location of the Earth caused by
the weight of the column of air above it. One atmospheric pressure refers to
the average pressure and gradually decreases as altitude increases.
Meteorologists use barometers to measure atmospheric pressure. Since variation
in atmospheric pressure greatly affected by weather, it is possible to
forecast the weather by measuring the changes in pressure.
Select display mode
- Press and hold button for 2 seconds to enter atmospheric pressure setting mode.
- Use or button to select between absolute and relative
atmospheric pressure:
• ABSOLUTE the absolute atmospheric pressure of your location
• RELATIVE the relative atmospheric pressure based on the sea level
Set relative atmospheric pressure value
- Get the atmospheric pressure data of the sea level (it is also the relative atmospheric pressure data of your home area) through the local weather service, internet and other channels.
- Press and hold button for 2 seconds until ABSOLUTE or RELATIVE flashes.
- Press or button to switch to RELATIVE mode.
- Press button again and the number for RELATIVE flashes.
- Use or button to change the value.
- Press button to save and exit the setting mode.
NOTE!
- The default relative atmospheric pressure value is 1013 mb/hPa (29.91 inHg), which refers to the average atmospheric pressure.
- When you change the relative atmospheric pressure value, the weather indicators will change along with it.
- The built-in barometer can notice the environmental absolute atmospheric pressure changes. Based on the data collected, it can predict the weather conditions in the forthcoming 12 hours. Therefore, the weather indicators will change according to the detected absolute atmospheric pressure after you operate the clock for 1 hour.
- The relative atmospheric pressure is based on the sea level, but it will change with the absolute atmospheric pressure changes after operating the clock for 1 hour.
Select barometer measurement unit
Press button several times until the desired measurement unit is displayed:
inHg, mmHg or hPa.
TEMPERATURE & HUMIDITY
Comfort Indication
The comfort indication is a pictorial indication based on indoor air
temperature and humidity in an attempt to determine comfort level.
HINWEIS!
- Comfort indication can vary under the same temperature, depending on the humidity.
- There is no comfort Indication when temperature is below 0°C (32°F) or over 60°C (140°F).
RAINFALL
Select display mode
The device displays how many mm / inches of rain are accumulated in a one hour
time period, based on current rainfall rate.
Press button several times until the disered time range is displayed:
• RATE: | Current rainfall rate in past an hour |
---|---|
• DAILY: | Total rainfall from midnight |
• WEEKLY: | Total rainfall from the current week |
• MONTHLY: | Total rainfall from the current calendar month |
NOTE!
Rain rate is updated every 6 minutes, at every hour on the hour, and at 6, 12,
18, 24, 30, 36, 42, 48, 54 minute past the hour.
Select rainfall measurement unit
- Press and hold button for 2 seconds to enter settings mode.
- Use or button to select mm (millimeter) or in (inch).
- Press button again to confirm and exit.
WIND SPEED / DIRECTION
Reading the wind direction
Wind direction indicator | Meaning |
---|---|
Real-time wind direction | |
Wind directions appeared in last 5 minutes (max 6) |
Select display mode
Press button several times until the desired rate is displayed:
- AVERAGE: average of all wind speed numbers recorded in the previous 30 seconds
- GUST: highest wind speed (gust) recorded from last reading
The wind level provides a quick reference on the wind condition and is indicated by a series of text icons:
Wind level | LIGHT | MODERATE | STRONG | STORM |
---|---|---|---|---|
Speed | 2-6 mph | |||
3-13 km/h | 9-25 mph | |||
14-41 km/h | 26-54 mph | |||
42-87 km/h | ≥ 55 mph |
≥ 88 km/h
Select wind speed unit
- Press and hold button for 2 seconds to enter unit setting mode.
- Use or button to change the unit between mph (miles per hour) / m/s (meter per second) / km/h (kilometer per hour) / knots.
- Press button to confirm and exit.
Be – aufort-Nummer | Beschreibung | Geschwindigkeit |
---|---|---|
0 | calm | < 1 km/h |
< 1 knot | < 0.3 m/s | |
1 | lightair | 1.1-5.5 km/h |
1-3 knot | 0.3-1.5 m/s | |
2 | light | |
breeze | 5.6-11 km/h | 4-7 mph |
4-6 knot | 1.6-3.4 m/s | |
3 | gentle | |
breeze | 12-19 km/h | 8-12 mph |
7-10 knot | 3.5-5.4 m/s | |
4 | moderate | |
breeze | 20-28 km/h | 13-17 mph |
11-16 knot | 5.5-7.9 m/s | |
5 | fresh | |
breeze | 29-38 km/h | 18-24 mph |
17-21 knot | 8.0-10.7 m/s | |
6 | strong | |
breeze | 39-49 km/h | 25-30 mph |
22-27 knot | 10.8-13.8 m/s | |
7 | high | |
wind | 50-61 km/h | 31-38 mph |
28-33 knot | 13.9-17.1 m/s | |
8 | gale | 62-74 km/h |
34-40 knot | 17.2-20.7 m/s | |
9 | strong | |
gale | 75-88 km/h | 47-54 mph |
41-47 knot | 20.8-24.4 m/s | |
10 | Storm | 89-102 km/h |
48-55 knot | 24.5-28.4 m/s | |
11 | violent | |
storm | 103-117 km/h | 64-73 mph |
56-63 knot | 28.5-32.6 m/s | |
12 | Hurricane | |
force | ≥ 118 km/h | ≥ 74 mph |
≥ 64 knot | ≥ 32.7 m/s |
WIND CHILL / HEAT INDEX / DEW-POINT
Reading wind chill
Press INDEX button several times until WIND CHILL is displayed.
Reading heat index
Press INDEX button several times until HEAT INDEX is displayed.
Heat index | Warning | Meaning |
---|
27° C – 32° C
(80° F – 90° F)| Caution| Possibility of heat exhaustion
33° C – 40° C
(91° F – 105° F)| Extreme caution| Possibility of dehydration
41° C – 54° C
(106° F – 129° F)| Danger| Heat exhaustion likely
≥ 55° C
(≥ 130° F)| Extreme danger| Strong risk of dehydration / sun stroke
Reading dewpoint (indoor)
Press INDEX button several times until INDOOR DEWPOINT is displayed.
NOTE!
The dew point is the temperature below which the water vapor in air at
constant barometric pressure condenses into liquid water at the same rate at
which it evaporates. The condensed water is called dew when it forms on a
solid surface.
The dewpoint temperature is calculated from the indoor temperature and
humidity measured at the main unit.
HISTORY DATA
(all records in the past 24 hours)
The main unit automatically records and displays data of the past 24 hours on
the hour.
To check all the history data in the past 24 hours, press the HISTORY button.
E.g. current time 7:25 a.m., Mach 28:
Press HISTORY button repeatedly to view past readings at 7:00am, 6:00am,
5:00am, …, 5:00am (Mar 27), 6:00am (Mar 27), 7:00am (Mar 27) The LCD will
display the past indoor and outdoor temperature & humidity, value of air
pressure, wind chill, wind speed, rainfall and their time and date.
MAXIMUM / MINIMUM MEMORY FUNCTION
-
Press MAX/MIN button to check the maximum/minimum records.
The checking orders will be: Outdoor max temperature > Outdoor min temperatureOutdoor max humidity > Outdoor min humidity > Indoor max temperature > Indoor min temperature > Indoor max humidity > Indoor min humidity > Outdoor max wind chill > Outdoor min wind chill > Outdoor max heat index > Outdoor min heat index > Indoor max dewpoint > Indoor min dewpoint > Max pressure > Min pressure > Max average > Max gust > Max rainfall.
-
Press and hold MAX/MIN button for 2 seconds to reset the maximum and minimum records.
NOTE!
When maximum or minimum reading is displayed, the corresponding timestamp will
be shown.
HI / LO ALERT
HI/LO alert are used to alert you of certain weather conditions. Once
activated, the alarm will turn on and amber LED starts flashing when a certain
criterion is met. The following are areas and type of alert provided:
Bereich | Verfügbarer AlarmTyp |
---|---|
Indoor temperature | HI AL / LO AL |
Indoor humidity | HI AL / LO AL |
Outdoor temperaturw | HI AL / LO AL |
Outdoor humidity | HI AL / LO AL |
Rainfall | HI AL* |
Wind speed | HI AL |
*Daily rainfall since midnight
HI / LO alert setting (Fig. 29)
- Press button several times until the desired area is selected.
- Use or buttons to adjust the setting.
- Press button to confirm and continue to next setting.
Enable/Disable HI / LO alert (Fig. 30)
- Press button several times until the desired area is selected..
- Press button to turn the alert on or off.
- Press button again to confirm and continue to next setting.
NOTE!
- The unit will automatically exit setting mode in 5 seconds if no button is pressed.
- When ALERT alarm is on, the area and type of alarm that triggered the alarm will be flashing and the alarm will sound for 2 minutes.
- Press SNOOZE/LIGHT button when alarm sounds to interrupt the alarm. The alarm will then start again after 5 minutes.
- Press button when alarm sounds to deactivate the alarm until next time.
The alarm automatically turns off after 2 minutes.
WIRELESS SIGNAL RECEPTION
The 5-in-1 sensor is capable of transmitting data wirelessly over an
approximate operating of 150m range (line of sight).
Occasionally, due to intermittent physical obstructions or other environmental
interference, the signal may be weaken or lost.
In the case that the sensor signal is lost completely, you will need to
relocate the main unit or the wireless 5-in-1 sensor.
POINTING 5-IN-1 SENSOR TO THE SOUTH
The outdoor 5-in-1 sensor is calibrated to be pointing to North by default.
However, in some cases, users may wish to install the product with the arrow
pointing towards the South, especially for people living in the Southern
hemisphere (e.g. Australia, New Zealand).
- First install the outdoor 5-in-1 sensor with its arrow pointing to the South. (Please refer to ‘Installation’ chapter for mounting details)
- Press and hold button for 8 seconds until the upper part (Northern hemisphere) of the compass rose is blinking.
- Use or button to change to lower part (Southern hemisphere).
- Press button again to confirm and exit.
NOTE!
Changing from hemisphere setting will automatically switch the direction of
the moon phase on the display.
MOON PHASES
In the Northern hemisphere, the moon waxes (the part of the moon we see that
glows after the New Moon) from the right. Hence the sun-lit area of the moon
moves from right to left in the Northern hemisphere, while in the Southern
hemisphere, it moves from left to right. Below are the 2 tables which
illustrate how the moon will appear on the main unit.
Northern hemisphere:
| New moon| | Full moon
---|---|---|---
| Waxing crescent| | Waning gibbous
| First quarter| | Third quarter
| Waxing gibbous| | Waning crescent
Southern hemisphere:
| New moon| | Full moon
---|---|---|---
| Waxing crescent| | Waning gibbous
| First quarter| | Third quarter
| Waxing gibbous| | Waning crescent
TROUBLESHOOTING
Problem/Symptom | Solution |
---|---|
Strange or no measurement of rain sensor | 1. Check drain hole in the rain |
collector.
Clean it if neccessary.
2. Check the circular level. Realign the device if neccessary.
Strange or no measurement of Thermo/Hygro Sensor| 1. Check radiation shield.
Clean it if neccessary.
2. Check sensor housing. Clean it if necessary
and — (no signal for 15 minutes)| 1. Relocate main unit and 5-in-1 sensor
closer to each other.
2. Make sure the main unit is placed away from other electronic appliances
that may interfere with the wireless communication (TV‘s, computers,
microwaves).
3. If problem continues reset both, main unit and 5-in-1 sensor.
and ER (no Signal for 1 hour)
SPECIFICATIONS
Main unit
Batteries| 3 x AA, 1.5 V
Barometer unit| hPa, inHg, mmHg
Barometer measuring range| 540 – 1100 hPa
Temperature unit| °C / °F
Temperature measuring range| -10° – 50° C
Humidity measuring range| 20% – 90%
Time display| HH:MM:SS
Time format| 12 or 24 hours
Calendar display| TT/MM/JR or MM/TT/JR
5-in-1 sensor
Batteries| 3 x AA, 1.5 V
Temperature unit| °C / °F
Temperature measuring range| -40° – 60° C
Humidity measuring range| 1% – 99%
Rainfall unit| mm, inch
Rainfall measuring range| 0 – 9999 mm (0 – 393.7 inch)
Wind speed unit| mph, m/s, km/h, knot
Wind speed measuring range| 0 – 112 mph, 0 – 50 m/s, 0 – 180
km/h, 0 – 97 knots
Wind direction display| 16
CLEANING AND MAINTENANCE
Before cleaning the device, disconnect it from the power supply (remove
batteries)!
Only use a dry cloth to clean the exterior of the device. To avoid damaging
the electronics, do not use any cleaning fluid.
Cleaning the rain collector (sinkhole)
- Rotate the rain collector by 30° anticlockwise.
- Gently remove the rain collector.
- Clean and remove any debris or insects.
- Install all the parts when they are fully clean and dried.
Cleaning the thermo/hygro sensor
-
Unscrew the 2 screws at the bottom of the radiation shield.
-
Gently pull out the shield.
-
Remove carefully any dirt or insects inside the sensor casing
NOTE!
The radiation shield comprises different parts inserted one inside another. Two bottom parts are closed. Do not change their order!
Do not let the sensors inside get wet! -
Clean the shield with water and remove any dirt or insects.
-
Install all the parts back when they are fully clean and dried.
DISPOSAL
Dispose of the packaging materials properly, according to their type, such
as paper or cardboard. Contact your local waste-disposal service or
environmental authority for information on the proper disposal.
Do not dispose of electronic devices in the household garbage! As per
Directive 2002/96/EC of the European Parliament on waste electrical and
electronic equipment and its adaptation into German law, used electronic
devices must be collected separately and recycled in an environmentally
friendly manner.
In accordance with the regulations concerning batteries and rechargeable
batteries, disposing of them in the normal household waste is explicitly
forbidden. Please make sure to dispose of your used batteries as required by
law — at a local collection point or in the retail market. Disposal in
domestic waste violates the Battery Directive.
Batteries that contain toxins are marked with a sign and a chemical symbol.
“Cd” = cadmium, “Hg” = mercury, “Pb” = lead.
EC DECLARATION OF CONFORMITY
Bresser GmbH has issued a “Declaration of Conformity” in accordance with
applicable guidelines and corresponding standards. This can be viewed under
www.bresser.de/download/7002512/CE/7002512_CE.pdf.
WARRANTY & SERVICE
The regular warranty period is 2 years and begins on the day of purchase.
To benefit from an extended voluntary warranty period as stated on the gift
box, registration on our website is required.
You can consult the full warranty terms as well as information on extending
the warranty period and details of our services at
www.bresser.de/warranty_terms.
http://www.bresser.de/download/7002512
Errors and technical changes reserved.
Manual_7002512_Weather-Center-WTW-5in1_de-en_BRESSER_v082020a
Bresser GmbH
Gutenbergstr. 2 · DE-46414 Rhede
Germany
www.bresser.de ·
service@bresser.de
References
- Bresser | Startseite | Expand Your Horizon mit BRESSER
- index · powered by h5ai 0.26.1 (http://larsjung.de/h5ai/)
- Bresser | Social | Expand Your Horizon
Read User Manual Online (PDF format)