The QolorFLEX 25x3A Dimmer is ideal for applications such as retail displays, signage, and general architectural work. It features 25 channels of control in a compact IP20 (indoor) rated enclosure. Ideal for 2, 3,4 or 5 color LED tape installations, it is fully DMX and RDM compatible and offers stand alone functions. The QolorFLEX 25x3A Dimmer requires a separate power supply providing input voltage of 12-24VDC. The maximum current load per channel is 3A with a maximum device output of 75A.CITY THEATRICAL 5811 QolorFLEX 25x3A
Dimmer-fig-1

Product Usage Instructions

  1. Connect the QolorFLEX 25x3A Dimmer to your DMX controller by using either the DMX five pin XLR input or the RJ45 connectors. DMX out can be either the five pin XLR output or the RJ45 output.
  2. Connect the appropriate power supply providing 12-24VDC to the power input screw terminals. Note* – The size of the power supply(s) must match the tape being used in both voltage and watts. QolorFLEX 25x3A Dimmer’s maximum output power rating is 900W (12V) and 1800W(24V).
  3. To Set for DMX Power up unit. Address screen (Axxx) will be showing in DMX Mode (run).Connect the appropriate power supply providing 12-24VDC to the power input screw terminals. Note* – The size of the power supply(s) must match the tape being used in both voltage and watts. QolorFLEX 25x3A Dimmer’s maximum output power rating is 900W (12V) and 1800W(24V).
  4. In DMX Mode:
    • DMX Mode: DMX Address, Quantity of channels controlled, 8 or 16 bit dimming, PMW frequency (00 to 30), Dimming curve 0.1 TO 9.9
    • DMX Profiles (Set to 2.1 for 16 bit dimming)CITY THEATRICAL 5811 QolorFLEX 25x3A Dimmer-fig-2
  5. To Set for Stand Alone Set to Stand Alone Mode by pushing ‘Up’ button until run1 is shown. Run1 denotes DMX mode. Hit ‘Enter’ button, and ‘Up’ button to select run2 which denotes Stand Alone Mode. Cycle power to unit.
  6. In Stand Alone Mode:
    • Stand Alone Mode (cycle power after changing Run mode)
    • xx.xx = Output channel 2 level
    • X = Chase 1-4CITY THEATRICAL 5811 QolorFLEX 25x3A Dimmer-fig-3
    • DMX Start Address Sets the DMX address for the dimmer.
    • Output Resolution – (Factory default is 16)
    • Resolution determines the smoothness of the dimming. 8 bit uses 1 DMX channel, while 16 bit uses 2. Note: also change DMX profile to dp2.1
    • AVAILABLE SETTINGS: 08 or 16
    • PMW Frequency – (Factory default is 05)
    • PMW frequency is used to tune the dimmer for flicker free operation when used with high speed camera. A high PMW value produces better dimming quality. Always perform a camera test for optimal results.
    • AVAILABLE SETTINGS: 00 thru 30
    • Values: 00 = 500Hz, 01 to 30 = 1kHz to 30kHz
    • Dimming Curve – (Factory default is 1.5)
    • The dimming Curve may be adjusted to affect the rate of rise and fall of the dimmer. Values less than 1.0 increase the rate, while values greater than 1.0 decrease the rate. (1.0 is linear)CITY THEATRICAL 5811 QolorFLEX 25x3A Dimmer-fig-5 CITY THEATRICAL 5811 QolorFLEX 25x3A Dimmer-fig-6

DMX Console Slider Number

DMX channel Output Dimming
1 output 1 dimming
2 output 1 dimming output 2
3 output 2 dimming output 3
4 output 2 dimming micro dimming output 4
5 output 3 dimming dimming output 5
6 output 3 dimming micro dimming output 6
7 output 4 dimming dimming output 8
9 output 5 dimming dimming output 10
11 output 6 dimming dimming

CITY THEATRICAL 5811 QolorFLEX 25x3A Dimmer-fig-7

475 BARELL AVE,
CARLSTADT,
NJ 07072 800/230/9497.
201/549/1160.
201/549/1161
www.citytheatrical.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

City Theatrical User Manuals

Related Manuals