GE current GEH6049 LED Area Light

BEFORE YOU BEGIN

Read these instructions and save for future use.
WARNING
RISK OF ELECTRIC SHOCK

Risk of electrical shock. Disconnect power before service installation, or maintenance of the product.
RISK OF INJURY OR DAMAGE
Unit will fall if not installed properly. Follow installation instructions.
CAUTION
RISK OF INJURY
Risk of electrical shock. Disconnect power before service installation, or maintenance of the product.
RISK OF INJURY
The luminaire should be mounted so that prolonged staring into the luminaire at a distance closer than 0.50m is not expected.

Storage & Handling

GE current GEH6049 LED Area Light - figure

Slipfitter Mounting

GE current GEH6049 LED Area Light - figure 1

Once level, tighten bolts evenly.
WARNING
RISK OF DAMAGE
Do not torque bolts greater than 12 ft-lbs. Damage may occur.

Pole Mounting

GE current GEH6049 LED Area Light - figure 3

Knuckle Mounting

GE current GEH6049 LED Area Light - figure 4

WARNING
RISK OF DAMAGE
Do not torque bolts greater than 20 ft-lbs. Damage may occur.
WARNING
RISK OF DAMAGE
Do not torque mounting bolt greater than 22 ft-lbs and knuckle bolt greater than 50 ft-lbs. Damage may occur.

Knuckle Wall Mounting

GE current GEH6049 LED Area Light - figure 5

WARNING
RISK OF DAMAGE
Select user-supplied wall anchors and anchor fasteners suitable forthe wall construction and the fixture’s mounting hole diameters.
Ensure a minimum per-anchor pull-out-strength of 10 times (10X)the fixture weight and install per the manufacturer’s instructions.

Wiring

GE current GEH6049 LED Area Light - past pipe

CAUTION
RISK OF DAMAGE
Follow applicable national and local electrical codes.
Verify supply voltage and wire insulation temperature rating match nameplate requirements.

Photoelectric Control

GE current GEH6049 LED Area Light - past pipe 1

Door Closing

GE current GEH6049 LED Area Light - past pipe 2

Cleaning

GE current GEH6049 LED Area Light - past pipe 3

CAUTION
RISK OF DAMAGE.
Do not use soap/detergent containing aromatic hydrocarbons.

Specifications

Luminaire| Approx. Net Wt.| Dimensions| IP Rating| Mounting Height| Effective Projected Area| Operating Temp.
---|---|---|---|---|---|---
EALS/P| < 35 lbs (15.9 kg)| 25.2 x 16 x 4.6 in – Shipfitter/ (640 x 406 x 117 mm) 27.9 x 16 x 7.7 in – Univ. Arm/
Braze universal (709 x 406 x 196 mm)
29.2 x 16 x 10 in – Knuckle/ (742 x 406 x 254 mm)| Optical: – IP66
Electrical Enclosure:
td – UL Wet Location| 27-40 ft.
(8.2-12.2 m)| 0.54 ft (0.05 m 2 ) – Slipfitter/
0.63 ft (0.06 m 2 ) – Univ.
0.73 ft (0.07 m 2 ) – Knuckle/2.45 ft (0.23 m 2
) – Knuckle @ 45°| -40° to/à 40°C
EACL| <20 lbs (9.1 kg)| 19.5 x 12 x 4.6 in – Slipfitter/ (495 x 305 x 117 mm) 22.2 x 12 x 7.7 in – Univ. Arm/ Brazo universal (564 x 305 x 196 mm) 23.5 x 12 x 10 in – Knuckle/ (597 x 305 x 254 mm)| 16 -27 ft.
(4.9-8 m)| 0.37 ft (0.03 m 2 ) – Slipfitter/
0.52 ft (0.06 m 2 ) – Univ. Arm/ Brazo universal 0.56 ft (0.05 m 2 ) – Knuckle/1.03 ft (0.10 m 2
) – Knuckle @ 45°| -40° to/à 50°C*

*Selected SKU’s 50°C. See Datasheet

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to GE Current a Daintree company.
For additional information on the electrical parameters see the product label.
Importado por:
CURRENT COMMERCIAL MATERIALS S. DE R.L. DE C.V.
Av. Santa Fe 505, Piso 22, Suite/oficinas 22-106
Cruz Manca , Cuajimalpa de Morelos, C.P. 05349
Ciudad de México
Tel: +52 55 41696522
gecurrent.com/evolve
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GE current User Manuals

Related Manuals