legrand 4 120 15 Connected Energy Meter
Requires the installation of a:
Composition
| | | |
Accuracy
|
Measure
---|---|---|---|---|---
+5°C
+45°C
|
100-240V~
50 / 60Hz
|
80A MAX
|
2,4 à
2,4835Ghz
<100 mW
|
+/-1%
under 63A
|
Global
or
Per circuit
CE Directive
Compliant with the following European directive:
Low voltage directive
(LVD) 2014/35/UE
Electromagnetic compatibility
(CEM) n° 2014/30/UE
Imperative security precaution
The instructions for installation and use must be strictly observed in order to avoid the risk of electric shock or fire.
**Preparation, connexion
**
**Wiring
**
A circuit breaker with rated current C2 to C16 is necessary depending on wire
section used for supplying the energy meter.
*: Do not use on a three Lines electrical installation.
N (neutral) = blue L (Line) = Everything but blue and green/yellow
Add the Energy meter in a connected installation
Turn off the power at **general circuit breaker
Turn on the power at the general circuit breaker* once the installation completed and controlled
- In order to restart all connected products at the same time.
**: After wiring the installation, refit the front plate so that no active live part is accessible.
Finalize the installation in the Legrand Home + Control app
Download the Home + Control App and follow the instructions for adding the connected product in your setup.
You also have the option of controlling your installation via a voice assistant. and can customize your scenarios via the Home + Control App.
| |
---|---|---
Reset an Energy meter to remove it from a connected installation
Press the the configuration button of the Energy meter (> 5 seconds) until the
configuration indicator lights up in fixed red.
It is no longer associated with the gateway present in the installation.
http://www.legrand.fr/reference/412015
LEGRAND – Pro and Consumer Service – BP 30076
87002 LIMOGES CEDEX FRANCE • www.legrand.com
UE SIMPLIFIED DECLARATION OF CONFORMITY
The undersigned,
Legrand
declares that the radio equipment listed on this instruction sheet are
compliant to the directive 2014/53/UE.
The full text of the UE declaration of conformity is available at the
following website:
www.legrandoc.com
References
- Welcome to Legrand - Legrand
- 412015 Compteur d'énergie connecté DRIVIA with Netatmo - livré avec 1 transformateur de courant fermé 80A - 1 module - professionnel | Legrand
- Legrand E-catalog International | Electrical Ranges of products & Connected Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>