BSG BioZone AC 05 Air Purifier Owner’s Manual

June 12, 2024
BSG

BioZone AC 05 Air Purifier

BSG BioZone AC 05 Air Purifier-product

Product Information

The BioZone AC series consists of four models: AC05, AC10, AC20, and AC30. These air purifiers are designed to provide a clean and pleasant environment by eliminating odors and purifying the air. The BioZone AC is the result of extensive research and product development, ensuring its effectiveness in air purification. It is intended solely for this purpose and should only be used as described in the operating instructions. The device features BSG technology, which enhances its air purification capabilities. For warranty information, please refer to the attached warranty card or contact your local distributor.

Specification

BSG BioZone AC 05 Air Purifier-fig-3BSG
BioZone AC 05 Air Purifier-fig-4 BSG
BioZone AC 05 Air Purifier-fig-2

Number of air changes per hour is calculated based on assumption of a restroom with three toilet seats 90 dm3 ner second exhaust ventilation 16 2 m2 floor space and 2 5m room heiaht

Manufacturing material

Specifications and design are subject to change without notice.

Product Usage Instructions

Operational Safety:

Please follow these installation instructions carefully to ensure safe and proper use of the BioZone AC air purifier.

Installation:

Attention : Installation should be carried out by a maintenance mechanic or an appropriate professional.

  1. Inspect the device for any damage that may have occurred during transportation. If any damage is found, do not connect the unit to the power supply or attempt to use it. Instead, inform the dispatcher or retailer immediately.
  2. Check that all the components mentioned in the user manual are included in the package. If anything is missing, contact your supplier.
  3. To open the device cover, insert the key provided and rotate it a quarter turn in an anticlockwise direction. Remove the key.
  4. To remove the cover, insert a broad screwdriver or similar tool between the cover and base-plate. Gently pry it open. Note that the electronic components will remain attached to the base-plate.
  5. Before mounting the unit, connect the power cord to the device. Make sure the cord is within reach of a power supply outlet, but do not connect it yet.
  6. For mounting, there are four screw holes on the base-plate. Use the provided screws and rubber spacers to dampen resonance. Insert the spacers between the base-plate and the wall or ceiling before fastening the screws.
  7. Install the unit as close as possible to the ventilation shaft for the incoming air.
  8. Once mounted, align the cover with the base-plate and press it down to close it.
  9. Insert the key again and turn it a quarter turn in a clockwise direction. Remove the key.

Note: For specific dimensions, weight, power adapter information, lamp type, and minimum room size requirements, please refer to the user manual provided with your BioZone AC model.

General

When correctly installed and properly used, BSG AC enables an odour-free, hygenic and altogether pleasant environment.

  • BSG AC does not mask odours with chemicals such as those utilized in deodorisers – it actually removes the odours.
    BSG AC significiantly diminishes bacteria and harmful microorganisms on surfaces and in the air.

BSG AC is the result of extensive research and sustained product development. Indeed, BioZone Scientific International Inc. has more than a decade of experience in designing and manufacturing its products.

  • It has been demonstrated that BioZone AC is highly effective and safe to use and fully complies with the criteria of the world’s most respected certification bodies.
  • Certificates issued to this effect are listed in the Certifications section of this manual.
  • Every BSG AC unit has undergone a strict quality-control regime. However, should the unit malfunction, follow the instructions in the Troubleshooting section of this manual. If the problem persists, please contact your local distributor.
  • BioZone products are designed to be user-friendly with a high degree of functionality ease of operation and simple installation the primary considerations. User feedback is important for the continuous development of our products. We value your opinion and would greatly appreciate your feedback at email address: [email protected]
INTENDED USE

This device is used for air purification. It is intended solely for this purpose and is only allowed to be used for this purpose. It may only be used in the manner described in these operating instructions. Any other use or modification of the device is not intended and is strictly prohibited. No liability can be assumed for damage caused by improper use or incorrect operation.

BSG technology

As air enters the BSG unit, it is channeled into the air purification chamber. In the chamber, the air is exposed to intense levels of germicidal, ultraviolet light that destroys micro-organisms. The powerful wavelengths contained in the UV-light react with the gaseous contents of the air to produce a purifying plasma that contains reactive oxygen species such as atomic oxygen, hydroxyl radicals and ozone, which destroy bacteria, viruses, fungi, yeast, mould, algae, and other harmful micro-organisms (as well as unpleasant odours).

Warranty

Please see the attached warranty card, if included, or contact your local distributor. The provisions of this warranty are in lieu of any other written warranty, whether expressed or implied, written or oral, including any warranty of merchantability or tness for a particular purpose. The manufacturer’s maximum liability shall not exceed the actual purchase price paid by you for the product. In no event shall the manufacturer be liable for special, incidental, consequential or indirect damages. This warranty does not cover a defect that resulted from improper or unreasonable use or maintenance, accident, improper packing, or unauthorised tampering, alteration or modification as determined solely by us. This warranty is void if the label bearing the serial number has been removed or defaced.

Operational Safety

Operation and maintenance of this device should only be carried out by qualified technicians and persons appropriately trained or supervised in its use. This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Installation

ATTENTION! Installation must be carried out by a maintenance mechanic or appropriately

Unit components (Illustration A)

  • Cover
  • Locking shank (also functions as an ON/OFF switch)
  • Fan
  • Lamp element
  • Base-plate
  • Power cord
  • Key
  • Screw (4)
  • Rubber spacer (4)
  • Power plugBSG BioZone AC 05 Air Purifier-fig-1
Before installation

Inspect the device for damage that may have occurred during transportation. If the unit has been damaged, do not connect it to the power supply or try to use it otherwise. In the event of damage, immediately inform the dispatcher or retailer. Check that the aforementioned components are included in the package (some are inside the device). In the event that something is missing, contact your supplier.

Installation location

The BSG AC device must be installed

  • on a wall or ceiling at a height of approximately 2 metres (7 feet)
  • in a place where the air moves freely into and out of the device
  • in a place where it most effectively removes impurities from the air
  • such that it does not blow directly onto the face
  • such that it is within easy reach of the power-supply outlet

To gain maximum benefit from your BSG AC device, install it close to a fan or to the incoming air vent. In this way the purifying plasma will be mixed most effectively with the air in the room.

Installation instructions for versions with plugged cables
  1. Step 1
    Ex-factory, the device is locked by default. To open the cover, insert the key and rotate it a quarter turn in an anticlockwise direction. Remove the key.

  2. Step 2
    The cover is firmly attached to the base-plate. To remove it, insert a broad screwdriver or similar tool between the cover and base-plate and gently but firmly prise off the cover. The electronic components remain attached to the base-plate when the cover has been removed.

  3. Step 3
    It is important that the cable is connected to the device before mounting the unit and to ensure that the cord is within easy reach of a power-supply outlet. However, do not connect the power cord to the power outlet at this stage! For mounting, there are four screw holes on the base-plate. The mounting kit comprises four screws and four rubber spacers to dampen resonance. Before fastening the screws, insert the spacers between the base- plate and the wall or ceiling. To maximise efficiency, the outflow end (the one with the fan) of the unit should be installed as close as possible to the ventilation shaft for the incoming air flow. The arrow in the illustration indicates the direction of the air flow.

  4. Step 4
    Ensure that the lower end of the locking shank is lengthwise so that it fits neatly into the hole in the base-plate and press down the cover to close it.

  5. Step 5
    Insert the key, turn it a quarter turn in a clockwise direction and remove it.

  6. Step 6
    Connect the power cords grounded plug to an appropriate power supply outlet. The device will start-up and the indicator light will turn on

Installation instructions for versions with no plug
  1. Step 1
    Ex-factory, the device is locked by default. To open the cover, insert the key and rotate it a quarter turn in an anticlockwise direction. Remove the key.

  2. Step 2
    The To remove it, insert a broad screwdriver or the cover. The electronic components remain attached to the base-plate when the cover has been removed.

  3. Step 3
    For mounting, there are four screw holes on the base-plate. The mounting kit comprises four screws and four rubber spacers to dampen resonance. Before fastening the screws, insert the spacers between the base-plate and the wall or ceiling.

  4. Step 4
    the hole in the base-plate and press down the cover to close it.

  5. Step 5
    Insert the key, turn it a quarter turn in a clockwise direction and remove it.

Additional Guidelines for no plug version direct mains installation
For Permanent Connection to the Mains Supply, NOTE that Stationary appliances not in all poles that provides full disconnection under overvoltage category III must have a wiring rules.

Install the unit so the power can be disconnected before removing the cover for service. The unit is not internally fused ,therefore, the mains supply circuit must be fused. The unit is intended to operate continuously. Insure the power supply is continuous The un-terminated AC power cord installed on the unit conforms to the following IEC standard wire color coding:

ATTENTION! The unit’s electrical connection to the mains supply must be done according to national and local electrical codes by a qualified electrician.BSG BioZone AC 05 Air Purifier-fig-5

WARNING: These procedures should only be performed by a qualified electrician according to national and local electrical codes. Supply power should be turned off when replacing components or checking connections. Never perform maintenance or cleaning while fixture is energized

Maintenance instructions

Maintaining the unit is easy. The only serviceable/changeable component is the UV-lamp. If the device is located in a dusty or smoke-filled area, it is recommended that the lamp be cleaned every three months. This will significantly lengthen the life of the lamp. The lamp must be changed once a year in order to ensure maximum functionality and efficiency.

CAUTION! Disconnect the unit from the power supply network before servicing.
ATTENTION! Installation & lamp replacements must be carried out by a maintenance mechanic or apropriately qualified person only.by a maintenance mechanic or
ATTENTION! The UV-lamp must be allowed to cool down before cleaning.

Avoid touching the lamp’s glass element.
Handle the lamp by its white end caps only This UV-lamp is intended to produce photoplasma and is not suitable for illumination. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.

Cleaning and changing the lamp

  1. Disconnect the power supply to the device
  2. Open the unit in accordance with the installation instructions in this manual
  3. Ensure that the lamp has cooled down. Extract the lamp from its retaining clips (see illustration M). When handling the lamp, avoid touching the glass element with exposed fingers.
  4. Cleaning the lamp: Clean the lamp with a soft cloth and an appropriate cleansing solvent (i.e. isopropyl alcohol). Reinsert the lamp.
  5. Changing the lamp: Insert a new lamp (see technical specifications in this manual for correct lamp type). Use only a new BioZone Scientific Group lamp (using other lamps will void the warranty).
  6. Close the unit in accordance with the installation instructions in this manual.
  7. Connect the power.
  8. When the lamp has been replaced, dispose of the old lamp in accordance with local regulations pertaining to hazardous waste disposal. UV-lamps contain small traces or mercury.

Troubleshooting

In the event that the undermentioned instructions do not solve the problem, contact your supplier.

  1. The fan works, but the lamp is not on
  2. Check that the lamp is properly inserted into its socket
  3. The lamp may be defective. Replace the lamp with a new one
  4. The lamp and the fan do not function
  5. Check that the device is plugged in
  6. Check that the power outlet functions properly
  7. Check that the power chord is undamaged
  8. Check to see if the locking shank (which also functions as an ON/OFF switch) is fully turned and properly engaged.
  9. The airflow is weak
  10. Check to see if the grill is clogged with dust or debris
  11. Check for blockages to the incoming or outgoing air flow
  12. Check that the fan functions properly

Disposal/recycling

BioZone Scientific Group is an ISO-14001:2004-compliant company and is committed to environmental sustainability.

Packaging
Packing materials can be recycled. In the interest of environmental protection, dispose of these materials properly.

The unit and UV-lamp
If your BSG AC needs to be disposed of, do so in accordance with the instructions pertaining to standard electrical equipment. UV-lamps contain small traces of mercury. Old, defective or broken lamps must be disposed of in accordance with laws related to the disposal of hazardous waste.