GOLAND CENTURY SU05 S-Unit Remote Controller User Manual

June 12, 2024
GOLAND CENTURY

1.03.02.10026-1
S-Unit(SU05)
Remote ControllerGOLAND CENTURY SU05 S-Unit Remote
Controller User Manual
User Manual_S-series_MJ
CE, Rohs, ISO9001:2015
Subject to change without notice.

Smart Remote Controller S-User Manual
Dear Clients,
Thanks for choosing the S-series Smart Remote Controller.
With the S-Unit you own a state-of the art device which was developed according to the latest available technical standards. This manual gives important recommendations for  installing, programming, using and so on. Read it carefully inyour own interest please.

Panel graphics

GOLAND CENTURY SU05 S-Unit Remote Controller - Panel
graphics

Description of Function

It comes with a number of outstanding features, such as:

  • Professional design of intelligent remote controller settings for a variety of products
  • Large LCd display wite parameter and running status
  • Simple and clear configuration interface
  • Automatic sleeping without operation, press some keys to wake up
  • Power supply: (AA) x 2pcs batteries, Battery capacity indicator
  • Emergency light and SOS lights

Key operate instruction

Key Name

| Function| Long press key function
---|---|---

Set

| Parameter setting/ confirmation| Press   “Set”and“Light” key to lock or unlock the parameters
| 1.Menu Page Up 2.Increase the setting data| Continuous increase the setting data
| 1.Menu Page Down 2.Decrease the setting data| Continuous decrease the setting data

Back

| Return to the menu / exit| ____

Send

| Send Parameters| _____

Test

| Test the setting| ____
Read| Para- meter| Read Parameters| ___
Status| Read running status| __
Backlight| Turn on the LCD backlight| __
Light| 1. Open the emergency lighting

2. SOS lights switch

| Press “Light”and“Set” key to lock or unlock the parameters

Icon Description

4.1Battery capacity indication

GOLAND CENTURY SU05 S-Unit Remote Controller - Panel
graphidcs

If the battery capacity <25% then the battery icon flashes to remind the user to replace the battery.
4.2Key lock and unlock

4.3Communication success and failureGOLAND CENTURY SU05 S-Unit Remote
Controller - icon 6

Operating

GOLAND CENTURY SU05 S-Unit Remote Controller - Remote

5.1 Precautions

  • Install two AA batteries, positive and negative poles can not be reversed;
  • The remote controller will automatically enter sleep mode after 1min without any key operation;
  • The remote controller sets the solar controller one by one, could not set several controllers at the same time;
  • Turn on the backlight and lights will shorten battery life;
  • When the low battery symbol is displayed, please replace the battery;
  • If long time no operation, the battery should be taken out.

5.2 Wake Up

  1. Press”Set”or“ ”or“Back”will wake up the remote controller.
  2. Press the “Backlight” key to wake up the remote controller will also turn on the LCD backlight.
  3. Press the “Light” key to wake up the remote controller will also turn on the lights.

5.3 Parameter Setting

Press” “can browse the setting parameters, when you want to modify the shading parameter, you can press the “Set” key, then the cursor starts blinking, press the “ “ key, the current parameter can be adjusted, after adjustment is complete, press the “Set” key to change to the next parameter or press the “Back” key to exit the current parameter setting.
——For details, please refer to Chapter 7, “Parameters Setting.”
5.4 Send
When the parameters are set up , aim at the solar charge controller and press the “Send” key. If send successfully, remote controller displays “Send Successful” and will beep a long sound; if failed, remote controller displays “Send Failure” and beep three short sounds; if the parameters such as battery type, current or voltage load settings are wrong, remote controller displays “Data
Error” and beep three short sounds.
NOTE: If you press the “Send” key, do not immediately remove the remote controller, otherwise it will cause setup failed.
5.5 Test
Aim at the solar charge controller and press ”Test”key, the load will be on, press the “Test” key again the output power of the load will switch to 50%. Test mode will last for 1 min, then enter the normal work mode.
Note: This feature varies by controller, please refer to the controller ’s user manual.
5.6 Transport mode
Press the“ Back ” and“  Backl ight”key at the same time more than 3s, the remote controller beeps two short sounds, at this time, the upper left of the menu shows the content from “Setting” to “Transport “.
For the lithium series controller, press the “Test” key in the transport mode, the remote control shows “Transport OK” and will be a long sound, the controller goes into the transport mode. If the remote control shows “Transport Error” and beeps three short sounds, the controller does not enter the transport mode.
If you want to exit the transport mode, press the “Back” and“Backlight” key again at the same time more than 3s, the remote controller beeps one short sound and the upper left of the menu shows the content from “Transport ” to “Setting”.
To exit the transport mode, please refer to the controller’s user manual. ——
5.7 Read
5.7.1 Read the parameters
Aim at the solar charge controller and press the “Parameter”key, the remote controller will read the setting value of the controller. If reading successfully, the remote controller will beep a long sound and display the setting values, you can press ” “ key to navigate through the parameters, press the “Back” key to return to the previous page. If failed, the remote controller will display “Read Failure”and beep three short sounds, after 4s the remote controller automatically returns to the previous page.
5.7.2 Read the running status
Aim at the solar charge controller and press the”Status”key, the remote controller will read the running status of the controller. If reading successfully, the remote controller will beep a long sound and display the running status , you can press “ “ key to navigate through the data, press the “Back” key to return to the previous page. If failed, the remote controller will display “Read Failure”and beep three short sounds, after 4s the remote controller automatically returns to the previous page.
——For details, refer to Chapter 6, “Running status”
“Send” key does not work, only after press the “Back” key to exit, the “Send” key will be available.
  Whine display parameter or status successfully the”Send” key does not work, only after press the “Back” key to exit, the “Send” key will be available.

5.8 Backlight
Press the “Backlight”key, the backlight of the LCD will turn on, suitable to use in dark situation.
5.9 Light
Press the “Light” key, the emergency light will be on, press again will switch to the SOS light, press the key the third times, the light will be off.
If you did not shut down light, it will automatically turn off after 30s.
5.10 Lock
Press the“Set” and“Light”key at the same time more than 3s, the remote controller beeps two short sounds, then the“Set”key will be lock to prevent carelessness operation.
If you want to unlock, press the“Set”and“Light” key again at the same time more than 3s, the remote controller  beeps one short sound and the unlocked symbol comesout.
5.11 Buzzer

Beep length Instruction
__(A short sound) Unlock
(Two short sounds) Key lock
_(Three short sounds) Communication   failure
___(A long sound) Communication successful

Running Status

When you press “Status” key, the first line of the LCD  displays the system status, including “Charge”,
“Discharge” or “Convert” and so on.
If the controller is being protected for some reason, the remote controller will display failure information in priority, include “Over CD”,”Short CD”,”Low VD”,”Over VP”,”Over TD”,”Open CP” and”HardwareP”.
Please refer to the controller’s user manual to troubleshoot the system.

Name Name Describe
Charge charging
Discharge discharging
Convert in charge and discharge conversion
Over CD Over current disconnect
Short CD Short circuit disconnect
Low VD Low voltage disconnect
Over VP Over voltage protection
Over TD Over temperature disconnect
Open CP Open circuit protection
HardwareP Hardware protection
Num Name
--- ---
  Status:
1 Batt V
2 Load I
3 Load V
4 PV V
5 PV I
6 Energy
7 OD Times
8 FC Times
9 Day1-HV
10 Day1-LV
11 Day2-HV
12 Day2-LV
13 Day3-HV
14 Day3-LV
  1. Some types of controller are temporarily unable to detect PV current, the remote control displays “—.”
  2. When read status information successfully, press the“ “ key to navigate the page, press the “Back”key to return to the previous page.

Parameters setting

Num Name Range
1 Time1 0~6.5H+24H+D2D *1
2 Dim1 0~100%
3 Time2 0~7.5H
4 Dim2 0~100%
5 Time3 0~7.5H
6 Dim3 0~100%
7 Time4 0~7.0H+T0T
8 Dim4 0~100%
9 Time5 0~7.5H
10 Dim5 0~100%
11 D/N Thr 3.0~20.0V
12 D/N Dly 0~30min
13 Load I 0.15~6.0A
14 Dim Auto Yes/No/365      *2
15 Dim V 8.0~32.0V          *3
16 Dim % 1~20%
17 Battery LIQ/GEL/LI          *4
18 CVT 8.0~32.0V
19 CVR 7.5~31.8V          *5
20 LVD 10.8~11.8V,Soc1~Soc5* 6
21 LVR 11.4~12.8V       *7
22 0℃ Chg Yes/No/Slow    *8
23 DelayOff 10~150s             *9
24 Dim NP 0~100%              *10
Num Name describe Step Length
--- --- ---
1 The first working time 0.5H
2 Dimming   percentage 10%
3 The second working time 0.5H
4 Dimming percentage 10%
5 The third working time 0.5H
6 Dimming percentage 10%
7 The fourth working time 0.5H
8 Dimming percentage 10%
9 The fifth working time 0.5H
10 Dimming percentage 10%
11 Day/Night Threshold voltage 0.5V
12 Day/Night open load delay time 5min
13 Load current 0.05A
14 Automatic dimming
15 The voltage of start dimming 0.1V
16 Automatic dimming percentage 1%
17 Battery type
18 Charging voltage target 0.1V
19 Charging voltage recovery 0.1V
20 Low voltage disconnect 0.1V
21 Low voltage  reconnect 0.1V
22 0℃ Charging Protection
23 Sensing delay off time 10s
24 Dimming when no people 10%

Work Mode

8.1 Standard(24H)

GOLAND CENTURY SU05 S-Unit Remote Controller - Sunrise

For controllers with “Standard”function(Smart series), if “Time1” is set to “24H”or “7.0H”and sent to the controller successfully, the controller ’s load will always open.
For details, refer to the controller’s instruction manual.
8.2 Dusk to Dawn (D2D)GOLAND CENTURY SU05 S-Unit Remote Controller -
Sunrise 1 If “Time1” is set to “D2D”,the controller works in dusk to dawn mode.
If “Time1”is set to D2D mode, “Time4” can not be set to T0T mode.
8.3 Five-stage Night ModeGOLAND CENTURY SU05 S-Unit Remote Controller -
Sunrise 5

8.4 T0T mode can set the load on time before morning coming
GOLAND CENTURY SU05 S-Unit Remote Controller - Sunrise
2

If “Time4” of the S-Unit is set to “T0T”, this mode is T0T mode.

  • If Time4 is set to T0T mode, Time1 can not set to D2D mode.
    8.5 Infrared sense mode
    For controllers with infrared sensing function, if work mode is set to ”Five- stage Night Mode”or ”T0T mode”, “DelayOff” and “Dim NP”works in “Time3”and “Time4”period.
    If you set the operating mode parameters are as follows:
Num Name Setting Data
1 Time1 1.0H
2 Dim1 100%
3 Time2 2.0H
4 Dim2 80%
5 Time3 3.0H
6 Dim3 60%
7 Time4 T0T
8 Dim4 40%
9 Time5 2.0H
10 Dim5 100%
11 DelayOff 10s
12 NP Dim 10%

The controller works as follows:
After the arrival of the evening the first time the load is lit for 1 hour (full power 100%), the second time the load  is lit for 2 hours (power 80%), the third time load light for3 hours (when people is near the lamp then the load is 60% light, when people is away from the lamp the load is  60% 10% light), and then the controller according to the actual night time automatically calculate the length of thefourth paragraph (when people is near the lamp then the load is 40% light, when people is away from the lamp the load is 40% 10% light), the fifth time load light 2 hours (full power 100%).

Technical parameters

Battery model (AA) x 2Pcs
Power supply voltage 3.0V
Power consumed of sleep mode <6uA
Normal power consumption <6mA
Sending power consumption <20mA
Light consumption <15mA
Backlight   consumption <7mA
Effective distance <8m
Size(mm) 120x65x20 (L x W x H)
  92g(Not including the battery)
Automatic sleep 1min
Lighting time 30s
Backlight time 30s
2000mAH battery 50000 cycles
Working temperature -25℃~50℃
Protection degree IP22

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals