SEALEY VEN200.V4 Portable Ventilator Instruction Manual
- June 12, 2024
- SEALEY
Table of Contents
PORTABLE VENTILATORS WITH DUCTING
MODEL Nos: VEN200.V4, VEN250.V2, VEN300.V3
Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND
WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE
INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to instruction manual
SAFETY
1.1. ELECTRICAL SAFETY
‰ WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe
before using. Inspect power supply leads, plugs and all electrical
connections for wear and damage. Sealey recommend that an RCD (Residual
Current Device) is used with all electrical
products.
If the product is used in the course of business duties, it must be maintained
in a safe condition and routinely PAT (Portable Appliance Test) tested.
Electrical safety information: it is important that the following information
is read and understood.
1.1.1. Ensure that the insulation on all cables and on the appliance is safe
before connecting it to the power supply.
1.1.2. Regularly inspect power supply cables and plugs for wear or damage and
check all connections to ensure that they are secure.
1.1.3. Important: Ensure that the voltage rating on the appliance suits the
power supply to be used and that the plug is fitted with the correct fuse –
see fuse rating in these instructions.
X DO NOT pull or carry the appliance by the power cable.
X DO NOT pull the plug from the socket by the cable.
X DO NOT use worn or damaged cables, plugs or connectors. Ensure that any
faulty item is repaired or replaced immediately by a qualified electrician.
1.1.4. This product is fitted with a BS1363 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and
remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363 3 pin plug. If in doubt contact a
qualified electrician.
A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
B) Connect the BROWN live wire to the live terminal ‘L’.
C) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that
the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2 GENERAL SAFETY
√ Disconnect the ventilator from the mains power when not in use, and before
servicing or performing any maintenance.
√ Use the fan in dry areas only. Do not use in wet or high condensation
locations such as bathrooms, showers, or pools.
‰ WARNING! If a ventilator falls into water, immediately switch off at the
mains and disconnect from the mains power supply.
X DO NOT touch the ventilator until the mains power supply has been
disconnected.
√ Always disconnect the ventilator from the power supply when moving it from
one location to another.
√ Keep the ventilator clean and maintain in good condition (use an
authorised service agent).
√ Use recommended parts only (unauthorised parts may be dangerous, and will
invalidate your warranty).
X DO NOT stand the ventilator where it may be knocked over or off a surface,
or where the lead may cause a trip hazard.
X DO NOT use an extension cord unless it has been approved by an electrical
authority.
X DO NOT insert any objects through the fan guard.
X DO NOT allow children to operate the ventilator.
X DO NOT immerse the ventilator in water or any other liquid.
X DO NOT use the ventilator outdoors.
X DO NOT cover the ventilator.
√ When not in use store in a safe, dry, childproof location.
INTRODUCTION
Ideal for use where high-volume clean air delivery is required. Especially
designed to easily ventilate hot or fume laden work areas, creating a cleaner
and more pleasant working environment. Supplied with 5m ducting (VEN200AK1).
Optional 10m ducting
(VEN200AK2) available, but not supplied. The air mover/ventilator can be used
across multiple industries including, but not exclusive to; marine, roof
spaces and building sites, cable/pipe ducts and workshops. Light weight in
construction with large carry handle makes it easily portable. Fitted with 2m
cable and 3-pin plug. Ducting supplied is compatible with other leading
manufacturers products with Ø200mm.
SPECIFICATION
Model No:………………VEN200.V4……………… VEN250.V2 …………………..VEN300.V3
Air Flow:……………………. 1500m³/hr(882cfm) – 25m³/min……. 2700m³/hr(1589cfm) –
45m³/min …………..3900m³/hr(2295cfm) – 65m³/min
Efficiency category: ………..static ………………….. static ………………………………………………………….
static
Efficiency grade: ………….40 ……………………. 40 ………………………………. 40
Fan Diameter: ……………200mm ………………… 250mm ……………………….. 300mm
Fan Speed: ……………..2800rpm ……………….. 2800rpm ……………………… 2800rpm
Fuse rating: ……………..None stated …………….. 13A …………………………….. 10A
IP Rating: ………………IP55 ………………….. IP55 …………………………….IP55
Max.Airflow:………………..1500m³/hr(882cfm) – 25m³/min……. 2700m³/hr(1589cfm) –
45m³/min …………..3900m³/hr(2295cfm) – 65m³/min
Measurement category:……..C…………………….. C …………………………………C
Noise Level: …………….61dB(A) ……………….. 66dB(A)………………………..61dB(A)
Overall efficiency (n):……….45.8% …………………. 42.8% ……………………………51%
Power:…………………180W …………………. 300W……………………………500W
Replacement Ducting (5mtr):….VEN200AK1 . . . . . . . . . . . . . . . . .
VEN250AK1 ………………… VEN300AK1
Replacement Ducting (10mtr):…VEN200AK2 . . . . . . . . . . . . . . . . .
VEN250AK2 ………………… VEN300AK2
Static Pressure:…………..3.1mbar ……………….. 3mbar …………………………3.9mbar
Supply: ………………..230V ~ 50Hz…………….. 230V ~ 50Hz …………………230V ~ 50Hz
230V ~ 50HZ OPERATION
4.1. Decide on the direction of air flow, depending on your requirement
(ventilate or extract). See fig 1 for direction of air flow.
4.2. Ducting can be attached to either end of the ventilator depending on
whether you wish to remove/extract fumes or deliver fresh air into a work
space.
4.3. To change direction of air flow rotate the unit 180° as the air flow is a
fixed direction.
4.4. Secure ducting by pulling the string tight then move the toggle switch to
start the unit; select a low or high fan speed as required.
NOTE: The ducting has locating lugs attached to it; these can be used to
suspend the ducting if required.
DIAGRAM SHOWS VENTILATION OPERATION
ENVIRONMENT PROTECTION
**** Recycle unwanted materials instead of disposing of them as waste. All
tools, accessories and packaging should be sorted,taken to a recycling centre
and disposed of in a manner which is compatible with the environment. When the
productbecomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers anddispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice. Please note that other versions of this product are available.
If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk
or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk.
IP32 7AR
**** 01284 757500
sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
VEN200.V4, VEN250.V2, VEN300.V3 Issue: 3 30/01/23
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>