Intellipure 10600-9 Compact Air Cleaning Device User Manual
- June 12, 2024
- intellipure
Table of Contents
- Intellipure 10600-9 Compact Air Cleaning Device
- Product Information
- Specifications
- What’s In the Box
- Important Safety Precautions
- Setting up the Unit
- Exploded View & Specifications
- Setting up the unit
- Operation | Function Description
- Routine Care & Maintenance
- Troubleshooting
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Intellipure 10600-9 Compact Air Cleaning Device
Product Information
The Intellipure Compact DFS (Disinfecting Filtration System) Air Cleaning System is a compact and professional air cleaner designed in the USA. It guarantees better than HEPA performance at ultrafine particle levels, ensuring pure air and creating a healthier indoor environment. The model number of this device is 10600-9.
Specifications
- Power Requirements: 100-240V AC, 50~60Hz
- Speed Settings: Turbo, High, Medium, Low
- Wattage: 65W (Turbo), 25W (High), 15W (Medium), 9W (Low)
- Dimensions: 11.22 x 15.15 x 22.23 inches / 285 x 385 x 590 mm
- Weight: 17 lbs / 8 kg
What’s In the Box
- Intellipure Compact DFS Air Cleaning System Main Unit – 1
- 6-stage Prefilter (inside main unit) – 1
- Main Filter (inside main unit) – 1
- Power Cord – 1
- User Manual – 1
- Warranty Card – 1
Important Safety Precautions
- Please read all instructions before operating your air cleaner.
- Basic precautions should always be observed to reduce the risk of fire, shock, and injury.
- This equipment has a polarized plug. If the plug does not fit fully in the outlet, reverse the plug or contact qualified personnel to install the proper outlet.
- Do not use a wall outlet adapter or operate the air cleaner with an extension cord.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS EQUIPMENT HAS A POLARIZED PLUG (ONE
BLADE IS WIDER THAN THE OTHER).
THIS PLUG WILL FIT IN A POLARIZED OUTLET ONLY ONE WAY. IF THE PLUG DOES NOT
FIT FULLY IN THE OUTLET, REVERSE THE PLUG.
IF IT STILL DOES NOT FIT, CONTACT QUALIFIED PERSONNEL TO INSTALL THE PROPER
OUTLET. DO NOT ALTER THE PLUG IN ANY WAY. NOT RELEVANT TO AUSTRAILIA AND NEW
ZEALAND.
WARNING: DO NOT USE A WALL OUTLET ADAPTER. DO NOT OPERATE THIS AIR CLEANER WITH AN EXTENSION CORD. DO NOT OPERATE WITH A DAMAGED CORD OR PLUG.
Warning: To prevent fire or shock hazard, do not expose this unit to rain or moisture.
-
Place the unit on a flat and level surface to allow continuous airflow to the bottom and side intakes and top outlet grill.
-
Always unplug the air cleaner before moving it, opening the front panel, changing any filter or cleaning the unit.
-
Do not place any foreign objects inside the unit, electric shock and injury could result.
-
Do not use the unit if any part is damaged or missing.
-
Do not run the power cord under carpeting, near heaters, registers, radiators, stoves or fireplaces.
To avoid a tripping hazard, keep the power cord away from high-traffic areas. -
Never operate the air cleaner in areas where combustible gases, vapors or any other flammable materials are present.
-
Never immerse or spray the unit with water or other liquids. Do not clean the unit under running water.
-
The air cleaner is designed for indoor, residential use only.
WARNING: THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING
CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF
EXPERIENCE AND KNOWLEDGE , UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR
INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR
SAFETY.
WARNING: CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH
THE APPLIANCE.
Setting up the Unit
Carefully remove the unit from the carton and remove the dust bag covering the
unit. The dust bag is used to prevent scratches and damage during
transportation. Store it in a dry and cool place.
The unit is designed for indoor use only.
For First Use, Before Plugging In the Unit:
- The 6-stage prefilter is wrapped to ensure freshness. Follow the steps in the Routine Care and Maintenance section (Point 2 – filter replacement and maintenance) to remove the prefilter, unwrap it, and replace it in the unit.
- Inspect the power cord. If the power cord is damaged, please contact Intellipure’s customer service department to obtain a replacement.
- If your power cord is intact, plug in your unit and enjoy exceptionally pure air now!
Exploded View & Specifications
- Front Cover
- 6-Stage Prefilter
- DFS Grid
- Main Filter
- Inner Housing
- DC Motor
- Outer Housing
Setting up the unit
Carefully remove the unit from the carton and remove the dust bag covering the
unit. The dust bag prevents scratches and damage
to the unit during transportation. Please keep it in a dry and cool place. The
unit is a plug and play design for indoor use only.
For First Use, Before Plugging In the Unit
The 6-stage prefilter is wrapped to ensure freshness. Follow steps in Routine
Care and Maintenance Section Point 2 filter replacement and maintenance to
remove the prefilter, un-wrap and replace it in the unit. Inspect the power
cord. If the power cord is damaged, please contact Intellipure’s customer
service department to obtain a replacement. If your power cord is intact,
Congratulations! You may plug in your unit and enjoy exceptionally pure air
NOW!
- a) POWER Button – to turn unit on and off, exist sleep mode, and change speed setting.
- b) LOW Indicator – when lit in blue, unit is running at low speed
- c) MED Indicator – when lit in blue, unit is running at medium speed
- d) HIGH Indicator – when lit in blue, unit is running at high speed
- e) TURBO Indicator – when lit in blue, unit is running at highest speed (setting meant for speed cleaning)
- f) DFS Indicator – when lit in blue, the DFS function is on
when the indicator flashes, DFS grid needs to be cleaned and main filter needs to be replaced
Operation | Function Description
Power On/Off and Speed Control
- Plug the unit into a 100-240V, 50-60Hz power outlet. Unit goes on standby mode.
- Press POWER button, the unit starts operation on low speed. Speed indicator LOW is lit in blue.
- Press the POWER button to change speed. Speed changes once at a time from Low, Medium, High to Turbo. Turbo mode is the highest speed and is designed for short-term speed cleaning.
- After going through all four speeds, the unit turns off and goes back to standby mode.
Sleep Mode
- When unit is on standby mode, press the POWER button to turn unit on.
- Adjust the unit to desired speed.
- Sleep mode is activated automatically after 60 seconds. No need to press any button. All indicators on the control panel dim down. Unit will stay in desired speed.
- To deactivate sleep mode, press the POWER button once. The indicators light up in bright blue.
- Change speed, or turn unit off when sleep mode is deactivated.
- Unit automatically goes back to sleep mode again after 60 seconds.
Main Filter Replacement
- When unit is under normal operation, DFS function is turned on by default. The DFS indicator is lit in blue.
- When the DFS indicator flashes, DFS grid needs to be cleaned and the main filter needs to be replaced.
- Replace the main filter and reset the timer to reactivate DFS function.
- Press and hold the POWER button for 5 seconds to reset timer. DFS indicator quickly flashes 3 times and timer is reset. The timer can be reset when sleep mode is activated and deactivated.
WARNING: The appliance is not to be used by children or persons with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge
unless supervised or they have been given instruction.
This product complies with the maximum allowable concentration of ozone of
0.050 parts per million by volume (ppmv)
in a 24-hour period. The Health Canada Guideline 2010 recommends that the
maximum exposure limit, based on an average time of 8 hours, is 0.020 ppmv or
less when tested in a sealed, controlled room approximately 30 m3.
Routine Care & Maintenance
Filters need to be replaced or maintained properly to maximize the unit’s performance. The maintenance schedule is based on pollution level. Following is the recommended maintenance schedule for most environments. Adjust maintenance schedule according to application.
- Prefilter – replace every 6 months
- High Energy Grid – clean every 3 months
- Main filter – replace every 9-12 months
WARNING: DO NOT USE A WALL OUTLET ADAPTER. DO NOT OPERATE THIS AIR CLEANER WITH AN EXTENSION CORD. DO NOT OPERATE WITH A DAMAGED CORD OR PLUG.
Filter Replacement and Maintenance
Replacing the 6-stage Prefilter
-
Turn off the unit and unplug from the power outlet.
-
Open the front panel, using the side tabs located on the lower panel and pull towards you, then lift upwards. (fig 3)
-
Remove the 6-stage prefilter. The pre-filter should be cleaned monthly by using a small vacuum cleaner and replaced every 6 months. (fig 4)
Replacing the Main Filter -
Remove prefilter.
-
Using a screwdriver, remove the 2 screws holding the filter in place. (fig 5)
-
Remove and discard the old main filter.
-
Slide the new main filter into place. (fig 6) Secure the main filter with the two screws.
-
Reinstall the 6-stage prefilter and the front cover. (fig 7)
-
Press and hold the POWER button for 5 seconds to reset timer. DFS indicator quickly flashes 3 times and timer is reset. Timer can be reset when sleep mode is activated and deactivated.
Cleaning the High Energy Grid -
Turn off the unit and unplug from the power outlet.
-
Follow the steps of the filter replacement to remove the filters. Replace them if needed.
-
Use a pipe cleaner or small vacuum to gently clean the wires on the high energy grid. (fig 8)
Troubleshooting
-
Unit will not turn on.
- a. Check power connection: whether the unit is plugged into a working outlet.
- b. Check if the unit’s front cover is in place and snapped shut.
- c. Check if the fuse located in the power plug receptacle is blown. (fig 9)
-
The unit turns on but no air blows out.
- a. Check if the plastic wrap on main filter or prefilter has been removed.
-
Unit is ON, but no change in speed.
- a. Further examination by a trained technician is required.
Call Intellipure Customer Service or local distributor.
- a. Further examination by a trained technician is required.
-
DFS Indicator is flashing.
- a. The main filter needs to be replaced.
See the Maintenance section of this manual for filter replacement instructions.
- a. The main filter needs to be replaced.
-
DFS indicator is OFF.
- a. Further examination by a trained technician is required.
Call Intellipure Customer Service or local distributor.
- a. Further examination by a trained technician is required.
WARNING: IF ALL SUGGESTED STEPS HAVE BEEN TAKEN AND PROBLEMS PERSIST, CONTACT
INTELLIPURE CUSTOMER SERVICE DEPARTMENT OR YOUR LOCAL DISTRIBUTOR FOR FURTHER
EXAMINATION BY A TRAINED TECHNICIAN.
WARNING: RISK OF ELECTRIC SHOCK – THESE SERVICING INSTRUCTIONS ARE FOR USE BY
QUALIFIED PERSONNEL ONLY. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT PERFORM
ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS
YOU ARE QUALIFIED TO DO SO.
Warranty
Coverage
Intellipure offers a 5 Year Limited Warranty. 5 Years on motor and blower. 1
Year on electronic components.
Product Registration
Intellipure offers a 5 Year Limited Warranty. Customers in the United States
should complete the enclosed Warranty Registration Card and mail/fax it within
10 days of purchase to:
Intellipure Inc.
3420 Maple Ave. Pulaski, NY 13142-0485.
Phone: 315.298.2904 or Toll-Free: 1.800.843.3860.
Fax: 315.298.6992.
Customers outside of the United States should contact the local distributor to
complete the product registration process.
To make a product claim, call 1.315.298.2904 or your local distributor to
obtain a warranty claim number.
Limited Warranty
This limited warranty applies only to the repair or replacement of any
manufactured or supplied part of this product which, upon inspection by
Intellipure authorized personnel, proves to have failed in normal use due to
defects in material or workmanship. The sole responsibility of Intellipure
under this Limited Warranty is, in its sole discretion, to either repair or
replace a duly registered product (or defec-tive part thereof) with the same
or a comparable model within a reasonable period of time, subject to the
following exclusions, limitations, statutory rights, and warranty claim
procedures. This Limited Warranty is exclusive, and Intellipure expressly
disclaims all other or additional warranties, whether written or oral,
expressed or implied, including, but not limited to, warranties of
merchantability, workmanship, or fitness for a particular purpose.
Exclusions
- A. This Limited Warranty does not apply, or is void, as to any product or part damaged by (1) accident, misuse, abuse, or lack of reasonable care or normal maintenance; (2) installation or operation under conditions other than those recommended by Intellipure; (3) subjecting the product to any but the specified voltage; (4) servicing or disassembly by unauthorized personnel; (5) removing or defacing the serial number; or (6) modifying the original factory-assembled unit in any way.
- B. THIS LIMITED WARRANTY DOES NOT APPLY TO SHIPPING CHARGES FOR PRODUCT SHIPPED TO OR FROM THE FACTORY OR DESIG-NATED SERVICE CENTER IN CONNECTION WITH WARRANTY CLAIMS NOR DOES IT APPLY TO ANY DAMAGES OCCURRING DURING EACH SHIPMENT.
- C. This Limited Warranty does not apply to installation, removal, re-installation, and/or related expenses. This Limited Warranty does not apply to replaceable filters and high-energy grid wires.
Limitations
Intellipure shall not be liable for property, incidental, and/or consequential
damages of any kind and, unless otherwise prescribed by applicable state law,
Intellipure shall not be liable for personal injury resulting from
malfunctions, defects, misuse, improper operation or installation, or
alteration of an Intellipure product or any part thereof. The exclusive remedy
for a breach of this Limited Warranty is the repair or replacement of the
defective product. In no case, shall liability under any other remedy
prescribed by law exceed the purchase price of the product.
Statutory Rights
This Limited Warranty, subject to the above exclusions and limitations, gives
you specific legal rights in addition to statutory rights you may have under
applicable state law. Some states, however, do not permit the limitation or
exclusion of incidental or consequential damages, so much limitation may not
apply to you. To the extent that any provision of this Limited Warranty is
inconsistent with applicable law, such provision shall be deemed void or
amended, as necessary, to comply with such law.
Intellipure Customer Service
US Corporate Office
3420 Maple Avenue, Pulaski NY USA 13142
Tel: (+1) 315-298-2904 Toll Free
1.800.843.3860
Please contact your local dealer for timely and professional service.
All rights reserved©. Specifications are subject to change without notification. Manufacturer P/N: 10-950. Download your digital user manual from our website: http://www.intellipure.com/user-manuals/
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>