ETEKCITY MSR-C600 Digital Clamp Multimeter
Overview
This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes strictly.
Warning
- To avoid electric shock or personal injury, read the “Safety Information” and carefully before using the Meter.
- MSR-C600 is 2000-count stable, safe and reliable digital clamp multimeter. It is designed with large-scale integrated circuits and AID converter as the core as well as the overload protection and novel structure, which make it a superb tool for electricians.
- The Meter can measure AC/DC voltage, AC current, resistance, diode, continuity and so on.
Unpacking Inspection
Open the package case and take out the Meter. Check the following items carefully for any missing or damaged part:
Item | Description | Qty |
---|---|---|
1 | Diaital Clamp Multimeter | 1 pc |
2 | Carrvina Pouch | 1 pc |
3 | User Manual | 1 pc |
Safety Information
- This Meter complies with the standard IEC61010: Pollution Degree 2, Overvoltage Category (CAT. II 600V, CAT. Ill 300V) and Double Insulation.
- CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient overvoltages than CAT. Ill.
- CAT. III: Distribution level, fixed installation, with smaller transient overvoltages than
- CAT. IV
- Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired.
- In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the Meter or the equipment under test.
- A Note identifies the information that user should pay attention to.
Warning
-
To avoid possible eleclric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, adhere to the following rules:
Before using the Meter in&pect the case. Do not use the Meter if ii is damaged or the case (or part of the case} is removed- Look for cracks or missing plastic. Pay attention to the insulation around The connectors. -
Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Raplaoa damaged test leads with identical modal number or electrical specifications before using the Meter.
-
Do not apply more than the rated voHage, as marked on the Meter, between the terminals or batwean any terminal and grounding. If the value to be measured is unknown, use the maximum range and reduce the range & step by step until a satisfactory reading is obtained.
-
When measurement has been 00fT1Jluted, disconnect lest leads from the circuits under test, remove the testing leads rttNaY from the input terminals of the Meter and tum the Meler power off.
-
The rotary switch should be placed in the right position and no any changeover of range shall be made during measurement to prevent damage of the Meter.
-
• To avoid electric shock, do not carry out Iha measurements when the Meter’s back CBll8 and battery compartment are not closed .
-
Do not input higher than 60CN between Iha Metar’s terminals and the grounding to avoid electric shock and damages to the Meter.
-
When the Meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken for there is danger of electric shock.
-
Use the proper terminals, function. and range for your measurements.
-
Do not use or store Iha Meter in an environment of high temperature, humidity, explosive, inflammable and strong magnetic field. The performance of the Meter may deteriorale after dampened.
-
When using the test leads, keep your fingers behind the finger guards.
-
Disconnect circuH power and discharge all high-voltage capacitors before testing resistance, continuity and diode.
-
Replace the battery as soon as the battery indicator appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury.
-
When servicing the Matar, use the replacement parts with this same modal or ldentlcal electrical specifications.
-
To avoid any damage to the meter or any accident, do not alter the Internal circuit of the Meter randomly.
-
Soft cloth and mild detergent should be used to clean the surface of the Meler when servicing.
-
No abrasive and solvent should be used to prevent the surface of the Meter from colT06ion, damage and accident.
-
The Meter is suitable for indoor use.
-
Tum the Meter off when ~ is not in use and take out the battery when not using for a longtime.
-
Conaantly check the battery as it may leak when it has been used for some time, replace the battery as soon as leaking appears. A leaking battery will damage the Meter.
International Electrical Symbols
The Meter Structure
- Input Terminals
- LCD Display
- Functional Buttons
- Rotary Switch
- Trigger: Push/release it to open/close the clamp jaw.
- Hand Guards: to protect user’s hand from touching the dangerous area.
- Transformer Jaws: designed to pick up the AC current flowing through the conductor. It could transfer current to voltage.
Rotary Switch
Below table indicated for information about the rotary switch positions.
Functional Buttons
- Below table indicated for information about the functional button operations.
Display Symbols
- Not every functional buttons can be used on every rotary switch positions.
Measurement Operation
DC Voltage measurement
Warning
- To avoid ham, to you or damages to the Meter from electric shock, do not attempt to measure voltages higher than BODY AC/DC, although readings may be obtained.
The DC Voltage ranges are: 200.0mV, 2.000V, 20.00V, 200.0V and 600V.
To measure DC voltage, connect the Meter as follows:
- Insert the red test lead into the terminal and the black test lead into the COM terminal.
- Set the rotary switch to .
- Connect the test leads across with the object being measured. The measured value is shown on the display.
Note
- In each range, the Matar has an input impedance of 1OM . This loading effect can cause measurement errors In high Impedance circuits. If the circuit Impedance is lass than or equal to 10kn, the error is negligible (0.1 or less).
- When DC wattage measurement has been completed, disconnect the connection between the tasting leads and the circuit under test and remove testing leads from the input terminals.
Measuring AC Voltage
Warning
- To avoid ham, to you or damage to the Meter from electric shock, do not attempt to measure voltages higher than 600V AC/DC, although readings may be obtained.
- The AC Voltage ranges are: 2.000V, 20.00V, 200.0V and 600V.
To measure AC voltage, connect the Meter es follows:
- Insert the red test lead into terminal and the black test lead into the COM terminal.
- Set the rotary switch to
- Connect the test leads across with the object being measured.
- The measured value shows on the display.
Note
- In each range, the Meter has an input impedance of 10M . This loading effect can cause measurement errors in high-impedance circles. If the circuit impedance is less than or equal to 10kn, the error is negligible (0.1 or less).
- When AC voltage measurement has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals.
Measuring Resistance
Warning
- To avoid harm to you, do not attempt to input voltages higher than 60V DC or 30V rms AC.
- To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before measuring resistance.
The resistance ranges are:
- 200.0 , 2.000k , 20.00k ,200k ,2.000M and 20.00M .
To measure resistance connect the Meter as follows:
- Insert the red test lead into the terminal and the black test lead Into the COM terminal.
- Set the rotary switch .
- Connect the test leads across wtth the object being measured.
- The measured value shows on the display.
Note
The test leads can add 0.1Cl to 0.3Cl of error to resistance measurement.
- For high-resistance measurement {>1 MCl), it is normal taking several seconds to obtain a stable reading.
- If reading with shorted test leads is notllii0.50, check for loose test leads, wrong function selectad, or enabled data hold function.
- The LCD displays OL Indicating open-Circuit or the tested resistor value is higher than the maximum range of the Meter
- Resistance measurement defaults to auto range mode.
- Measuring the tested object that is already removed from the in-line circuit can help to obtain a more accurate reading.
- When resistance measurement has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals.
Testing Diodes
Warning
To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before testing diodes.
Use the diode test to check diodes, transistors, and other semiconductor devices. The diode test sends a current through the semiconductor junction, then measures the voltage drop across the junction. A good silicon junction drops between 0.5V and 0.8V.
To test the diode out of a circuit, connect the Meter as follows:
- Insert the red test lead into the +-vs terminal and the black test lead into the COM terminal.
- Set the rotary switch to
- For forward voltage drop readings on any semiconductor component, place the red test lead on the component’s anode and the black test lead on the component’s cathode.
Note
- In a circuit, a good diode should still produoe a forward voltage drop reading of 0.5V to 0.8; however, the reverse voltage drop reading can vary depending on the resistance of other pathways between the probe tips.
- Connect the test leads to the proper terminals as said above to avoid error display.
- The LCD will display OL indicating either open circuit or wrong polarity connection.
- The unit of diode Is volt (V), displaying the forward voltage drop readings.
- Measuring the tested object that is already removed from the in-line circuit can help to obtain a more accurate reading.
- When diode testing has been completed, disconnect the connection between the tasting leads and the circuit under test and remove testing leads from the input terminals.
Testing for Continuity
Warning
- To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before measuring continuity.
To test for continuity, connect the Meter as follows:
- Insert the red test lead into the terminal and the black test lead into the COM terminal.
- Set the rotary switch to and press SELECT button to select measurement mode.
- The buzzer sounds if the resistance of a circuit under test is less than 50 .
- The buzzer may or may not sounds if the resistance of a circuit under test is between 50 2 to 120 .
- The buzzer does not sound if the resistance of a circuit under test is higher than 120 .
Note
- The buzzer beeps 5 times continuously on around 1 minute before entering the sleep mode. When it is just before entering the sleep mode, it will have one long beep to warn you.
- The LCD displays OL indicating the circuit being tested is open.
- When continuity testing has been completed. disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals.
Measuring AC Current
Warning
To avoid electric shock, never measure current while the test leads are inserted into the input terminals and disconnect test leads and tested circuit connection. Never attempt an in-circuit current measurement where the open- circuit voltage between the circuit and the ground is greater than 600V Use proper function and range for the measurement. The measuremnet ranges of current are: 2.000A, 20.00A, 200.0A and 400A.
To measure current, do the following:
- Set the rotary switch to 2/20A or 200/400 A
- Press the trigger to open the transformer jaws.
- Center the conductor within the transformer jaw. then release the Meter slowly until the transformer jaw is completely closed, Make sure the conductor to be to be tested is placed at the center of the transformer jaw, otherwise ii will casue deviation.
- The measured value shows on the display, ii is a effective value of sine wave (mean value response)
Note
- To obtain accurate reading, measure only one conductor at each time.
- When current measurement has been completed, disconnect the connection between the conductor under test and the jaw, and remove the conductor away from the transformer jaw of the Meter.
Sleep Mode
- To preserve battery life, the Meter automatically turns off if you do not tum the rotary switch or press any button for around 15 minutes.
The Meter can be activated by turning the rotary switch or pressing any button with the following conditions:
- The Hold function will be cancelled if the Meter is activated by pressing the HOLD button. To disable the Sleep Mode function, press and hold HOLD button while turning on the Meter.
Specifications
General Specifications
- Maximum voltage including transient overvoltage between any terminals and grounding: 600V rms
- Display: Maximum display 1999
- Auto Polarity Display
- Over1oading: Display OL or -OL
- Low Battery Indication: Display
- Measurement Speed: Updates 3 times/second.
- Measurement Deviation: When the conductor is measured is not pieced in a correct position during AC current measurement, it will cause±1% reading deviation.
- Drop Test: 1 meter drop test passed.
- Max. Jaw Opening: 28mm diameter.
- Tesled Max.
- Current conductor size: 26mm diameter.
- Power: 2pcs of 1 .5V battery (!AA)
- Battery Life: typically 150hours (alkaline battery)
- Sleep Mode (can be disabled)
- Dimensions (H x W × L): 30mm x 76mm x 208mm.
- Weight: Approximate 260g (battery included)
Environmental Restrictions
- The Meter is suitable for indoor use.
- Altitude: Operating: 2000m Storage: 10000m
- Safety/ Compliances: IEC 61010 CAT.|| 600V, CAT.III 300V over voltage and double insulation.
- Temperature and Humidity: Operating: 0°C-30°C (<75% R.H);30 C-40°C (<70%R.H); 40°C-50°C (<45%R.H); Storage: -20°C~+60°C (<75%R.H)
Accuracy Specifications
- Accuracy: ‡(a% reading + b digits), guarantee for 1 year
- Operating temperature: 23°C ‡ 5°C
- Relative humidity: <75%R.H
AC Voltage: Auto Ranging
Range | Resolution | Accuracy | Overload Protection |
---|---|---|---|
2.000V | 1mV |
±(1.2%+5)
|
600Vrms
20.00V| 10mV
200.0V| 100mV
600V| 1V| ±(1.5%+5)
Remarks
- Input impedance: 10M’1 <100pF
- Display sinewave RMS( AVG response)
- Frequency response: 40Hz-1 kHz.
- To adjust reading in accordance with effective value
DC Voltage: Auto Ranging
Range | Resolution | Accuracy | Overload Protection |
---|---|---|---|
200.0mV | 0.1mV | ±(0.8%+3) |
600Vrms
2.000V| 1mV|
±(0.8%+1)
20.00V| 10mV
200.0V| 100mV
600V| 1V| ±(1%+3)
Remarks: Input impedance: 10M .
Resistance: Auto Ranging
Range | Resolution | Accuracy | Overload Protection |
---|---|---|---|
200.0’1 | 100m | ±(1.2%+2) |
600Vp
2.000k’1| 1|
±(1%+2)
20.00kn| 10
200.0kn| 100
2.000M’1| 1k| ±(1.2%+2)
20.00Mn| 10k| ±(1.5%+2)
Remarks: Input impedance: 10M .
Continuity Test
Range | Resolution | Accuracy | Overload Protection |
---|---|---|---|
10Dmn | Around:< 50 the buzzer beeps | 600Vp |
Diode Test
Range | Resolution | Accuracy | Overload Protection |
---|---|---|---|
1mV | Display approximate |
forward voltage drop
0.5V 0.8V| 600Vp
Remarks: Open circuit voltage approximately 1.48V.
AC Current: Auto Ranging
Range | Resolution | Accuracy | Frequency Response | Overload Protection |
---|
2.DOQA
|
0.001A
| <1A(4%+40)
≥1A(3%+30))|
50Hz~60Hz
|
400A rms
20.DOA
|
0.01A
| +-(3%+12)
≤ 4A|
50Hz~60Hz
|
400A rms
+-(2%+8)
200.DA| 0.1A| +-(1.5%+5′
400A| 1A
Remarks
- Displays sinewave RMS (AVG response)
- To adjust reading in accordance with RMS value
Maintenance
This section provides basic maintenance information including battery replacement instruction.
Warning
- Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information.
- To avoid electric shock or damage to the Meter, do not get water inside the case.
General Service
- Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
- To clean the terminals with cotton bar with detergent, as dirt or moisture in the terminals can affect readings.
- Turn the Meter power off when it is not in use.
- Take out the battery when it is not using for a long time.
- Do not use or store the Meter in a place of humidity, high temperature, explosive, inflammable and strong magnetic field.
Replacing the Battery
Warning
- To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator ” EB” appears.
- Make sure the transformer jaw and the test leads are disconnected from the circuit being tested before opening the case bottom.
To replace the battery
- Tum the Meter off and remove all the connections from the input terminals
- Tum the Meter’s case top down.
- Remove the screw from the battery compartment, and separate the battery compartment from the case bottom.
- Remove the old battery from the battery compartment
- Replace the battery with 2pcs of new 1.5V (MA) battery.
- Rejoin the case bottom and the battery compartment, and reinstall the screw.
Warranty Information
Etekcity Corporation warrants all products to be of the highest quality in material, craftsmanship, and service for 2 years, effective from the date of purchase to the end of the warranty period. Warranty lengths may vary between product categories. If you have any questions or concerns about your new product, please contact our helpful Customer Support Team.
Customer Support
If you encounter any issues or have any questions about your new product, please contact our helpful Customer Support Team.
Etekcity Corporation
- 1202 N. Miller St., Suite A Anaheim, CA 92806
- Email:support@etekcity.com
- Toll-Free:855-686-3835
- Support Hours: Mon-Fri, 9:00 am-6:00 pm PST/PDT
Please have your invoice and order ID ready before contacting Customer Support.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>