FS T5850-24S2C Network Packet Broker User Guide
- June 12, 2024
- FS
Table of Contents
T5850-24S2C
NETWORK PACKET BROKER
Quick Start Guide V1.0
Introduction
Thank you for choosing T5850-24S2C Network Packet Broker. This guide is designed to familiarize you with the layout of the Network Packet Broker and describes how to deploy the Network Packet Broker in your network.
T5850-24S2C
Accessories
Power cord x2 Console cable x1 Network cable x1
Grounding cable x1 Mounting bracket x2
M4 screw x8 Rubber feet x4
Hardware Overview
Front Panel Ports
No.
|
Ports
| Description
---|---|---
1
|
Console
| An RJ45 console port for serial management
2
|
SFP+
| SFP+ ports for 10G transceivers
3
|
QSFP28
| QSFP28 ports for 40/100 G connection
4
|
ETH
| An Ethernet management port
Front Panel LEDs
- ID
- SYS
- SFP+
- QSFP28
- 40G Breakout LED
- ETH
LEDs
|
Status
| Description
---|---|---
SYS
|
Green
| On: The system is normal running.
Amber
| On: The system occurs alarm or error.
Off: No power or system is not run or abnormality.
Location
|
Blue
| On: ID indication function enable.
Off: ID indication function disable.
Main Power
|
Green
| On: Power supply ok.
Amber
| On: Power supply is abnormality.
Off: Power supply is absent or single power supply abnormality.
Backup Power
|
Green
| On: Power supply ok.
Amber
| On: Power supply is abnormality. Power supply is absent or single power
supply abnormality.
Off: Power supply is absent or single power supply abnormality.
MGMT
|
Green
| On: Port link.
Blinking: Port is receiving or transmitting packets.
Off: Port does not link.
Base-T
|
Green
| On: 1G port link.
Blinking: 1G packets receiving or transmitting.
Amber
| On: 10/100M port link.
Blinking: 10/100M packets receiving or transmitting.
Off: Port does not link.
SFP
|
Green
| On: 1G port link.
Blinking: 1G packets receiving or transmitting.
Amber
| On: 10/100M port link.
Blinking: 10/100M packets receiving or transmitting.
Off: Port does not link.
SFP+
|
Green
| On: 40G port link.
Blinking: 40G packets receiving or transmitting.
Amber
| On: 10G/1G port link.
Blinking: 10G/1G packets receiving or transmitting.
Off: Port does not link.
Breakout
|
Loop Blinking
| One or more 100G/40G ports are breakout.
Off
| None of the 100G/40G port is breakout.
Back Panel
- 3 Redundant Fans
- Hot-swappable Power Supplies
Installation Requirements
- The operating temperature is maintained at 0°C-45°C, the storage temperature is maintained at -40°C-85°C, the humidity is maintained at 10%-95%.
- Power source should be removed before cleaning Network Packet Brokers. Do not use wet rags to wipe Network Packet Brokers and clean it with liquid.
- Do not place Network Packet Brokers near water or in a wet environment and prevent water or moisture from entering Network Packet Broker chassis.
- Do not place Network Packet Brokers on an unstable case or table, since the dropping would cause serious harm to Network Packet Brokers.
- Maintain good indoor ventilation and clear air holes of Network Packet Brokers.
- Network Packet Brokers shall work normally under correct voltage, so make sure the operating voltage agrees with the voltage marked on Network Packet Brokers.
- To reduce the risk of electric shock, do not remove its enclosure when a Network Packet Broker is working, and don’t do so at will even if it is not powered.
- Anti-static gloves must be worn when replacing interface board to prevent static electricity from damaging veneer.
- During equipment transport and installation, prevent the equipment from colliding with objects like doors, walls, or shelves.
- Do not touch unpainted metal surfaces of equipment components with wet or contaminated gloves.
- Do not place other objects on the chassis.
Installation
Desk Mounting
- Attach four rubbers pads to the bottom.
- Place the chassis on a desk.
Rack Mounting
- Fix the tray to a proper position of rack horizontally.
- Take out screw (complete package with front hangers), and install one end of the Front Mounting Brackets on Network Packet Broker.
Installing the Power Supply Module
- Hold the handle of the Power Supply Unit with one hand and press on the top of the Network Packet Broker with another hand.
- Pull out the power module by smoothly sliding along the power slot until the plug of power module is completely separated from the socket inside chassis.
Grounding the Network Packet Broker
- Connect one end of the grounding cable to a proper earth ground, such as the rack in which the Network Packet Broker is mounted.
- Secure the grounding lug to the grounding point on the Network Packet Broker back panel with the washers and screws.
Connecting the Power
- Plug the AC power cord into the power port on the back of the Network Packet Broker.
- Connect the other end of the power cord to an AC power source.
Connecting the Console Port
- Insert the RJ45 connector into the RJ45 console port on the front of the Network Packet Broker.
- Connect the DB9 female connector of the console cable to the serial port on the computer.
Connecting the RJ45 Port
- Connect an Ethernet cable to the RJ45 port of IP cameras, IP phones, Access Points (AP), or other network devices.
- Connect the other end of the Ethernet cable to the RJ45 port of the Network Packet Broker.
Connecting the SFP/SFP+ Ports
- Plug the compatible SFP/SFP+ transceiver into the SFP/SFP+ port.
- Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to another fiber device.
Configuring the Network Packet Broker
Configuring the Network Packet Broker Using the Web-based Interface
Step 1: Connect the computer to any Ethernet port of the Network Packet Broker
using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x(“X” is any number
from 2 to 254). Set the subnet mask of the computer to 255.255.255.0
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password, admin/admin.
Step 4: Click Login to display the web-based configuration page. 9
Configuring the Network Packet Broker using the Console Port
Step 1: Connect a computer to the Network Packet Broker’s console port using
the console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the
computer.
Step 3: Set the parameter of the HyperTerminal: 115200 bits per second, 8 data
bits, no parity, 1 stop bit and no flow control.
Step 4: After setting the parameters, click Connect to enter.
Troubleshooting
Loading Failure Processing
After loading fails, the system will keep running in the original version. At this time, users should re-check if physical port connections are good firstly. If some ports are not connected, then re-connect them to ensure that physical connections are correct and begin re-loading. If physical connections are correct, then check the loading process information displayed on the super terminal to verify if there are input errors. If there are input errors, correct them and re-load. For example, when using TFTP protocol, we enter incorrect IP addresses of Server and Network Packet Broker, name of loading software, do not specify the correct working path of correct TFTP server and so on; if physical connections are good, and there are no input errors in the loading process, but the loading fails finally, please contact agents for help.
User Password Lost
If system password is lost or forgotten, the following method can be used to
reset password:
– Enter Uboot operation mode; see Chapter 5 for how to enter.
– Input boot_flash_nopass command to start system in Uboot mode.
After using boot_flash_nopass command, system will clear up the startup-config
files; before starting this operation, the startup-config files will be stored
in flash:/startup-config.conf.old file.
Power System Troubleshooting
Network Packet Broker can judge if its power system is faulty according to the
PWR indicator on the front panel: when power system works normally, the PWR
indicator shall always keep lighting; when the PWR indicator is off, please
check if:
– The power line of Network Packet Broker is connected correctly.
– EPS of Network Packet Broker matches the power required by Network Packet
Broker.
Configuration System Troubleshooting
After the Network Packet Broker is powered on, if system is normal, the startup information will be displayed on the configuration terminal; If the configuration system is faulty, the configuration terminal may display no information or hashes.
No Information On the Terminal
After power-on, if no display information on configuration terminal appears,
please check if:
1. The power is normal.
2.The cable of configuration port (Console) is properly connected.
If no problems have been found after the above checks, it is possible that
configuration cable is faulty or the parameter setting of terminal (such as
super terminal) are incorrect, please check accordingly.
3. Troubleshooting for the terminal displaying hashes:
If the configuration terminal displays hashes, it is probable that the
parameter setting of terminals (such as super terminal) are incorrect Please
confirm the parameter setting of terminals (such as super terminal): baud
rate: 115200, data bit: 8, parity: no, stop bit: 1, flow control: NA,
selecting terminal emulation: VT100.
Support and Other Resources
- Download https://www.fs.com/products_support.html
- Help Center https://www.fs.com/service/fs_support.html
- Contact Us https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that if there are any damage or faulty items due to our workmanship, we will offer a free return within 30 Days from the day you receive your goods. This excludes any custom made items or tailored solutions.
Warranty: T5850 Series Network Packet Brokeres enjoy 5 years limited warranty against defect in materials or workmanship. For more details about warranty, please check at https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at https://www.fs.com/policies/day_return_policy.html
Compliance Information
FCC
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this
device could void the user’s authority to operate the equipment.
Responsible party (only for FCC matter)
FS.COM Inc.
380 Centerpoint Blvd, New Castle, DE 19720, United States
https://www.fs.com
CE
FS.COM GmbH hereby declares that this device is in compliance with the Directive 2014/30/EU and 2014/35/EU. A copy of the EU Declaration of Conformity is available at www.fs.com/company/quality_control.html
FS.COM LIMITED
24F, Infore Center, No.19, Haitian 2nd Rd,
Binhai Community, Yuehai Street,Nanshan
District, Shenzhen City
FS.COM GmbH
NOVA Gewerbepark Building 7, Am
Gfild 7, 85375 Neufahrn bei Munich, Germany
IC
CANICES-3(A)/NMB-3(A)
Q.C. PASSED
Copyright © 2022 FS.COM All Rights Reserved.
References
- FS.com - HPC, Data Center, Enterprise, Telecom
- HPC, Data Centre, Enterprise, Telecom - FS.com United Kingdom
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- FS.com - Data Center, Enterprise, Telecom
- Contact Us - FS.com
- Kontakt - FS.com Deutschland
- Rückgaberecht - FS.com Deutschland
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- Technische Dokumente - FS.com Deutschland
- Hilfezentrum - FS.com Deutschland
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Comment Nous Contacter - FS.com France
- Documents techniques - FS.com France
- Politique de retour - FS.com France
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Centre d'aide - FS.com France
- Return Policy - FS.com
- Products Warranty - FS.com
- Technical Documents - FS.com
- Help Center - FS.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>