Antari Z-800 III Stage Fog Machine User Manual
- June 12, 2024
- Antari
Table of Contents
- Introduction
- Safety Information
- Package Contents & Inspection
- Machine Details
- Technical Label Information
- Fog Liquid
- Setting and Manual Operation
- Control Settings
- Machine Status
- Z-10 Cable Remote (Standard)
- Z-40 Timer Cable Remote (Optional)
- Z-50 Wireless Remote (Optional)
- Service and Maintenance
- Technical Specifications
- Warranty Disclaimer
- Machine Dimension
- Appendix I – Grounding Instruction
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Antari Z-800 III Stage Fog Machine
Introduction
Please read all the user manual before operating the machine, and place the manual where the user can refer to it at all time. The manual includes how to install and operate the machine under safe condition and explain all the labels printed on the machine. If you encounter any problem, contact your local Antari dealer for assistant immediately.
Safety Information
DANGER| If the danger is not avoided, it will cause death or serious
injury.
---|---
WARNING| If the warning is not heeded, it can cause death or serious
injury.
CAUTION| If the precaution is not taken, it may cause minor or moderate
injury.
DANGER
- Must connect the machine to the correct rated voltage or it might lead to an electrical shock or a burn and may cause serious consequences.
- Must connect the machine to a protected circuit and ensure it is properly grounded to avoid the risk of electrocution. For grounding instruction, please refer to Appendix I on page 15.
- Do not operate the machine with a bundled power cord, it could lead to a fire hazard.
- When operating the machine, do not point at people, animals, or fire.
WARNING
- Machine’s nozzle is extremely hot, please keep at least 50cm distance from the nozzle when the machine is running.
- Please operate the machine on a flat, level hard and well ventilated surface area, reserve at least 50cm space around the machine and make sure there is no flammable gas or material nearby.
- Do not disassemble, repair or modify the machine, it may cause damages, malfunction, risk of electrical shock or result in fire.
- The machine can only be operated by adults or professionals, is not intended for use by person with reduced physical sensory, mental capabilities, or lack of experience and knowledge including children.
- Do not leave the machine running unattended, make sure all powers are off when leaving.
- Children should be supervised to ensure that they do not play with the machine.
- Do not use the machine upside down or tilt it, it might cause damages or malfunction.
- Please store the fluid inside in a well ventilated area without direct sunlight and keep out of reach of children.
In case of eye contact or accidentally swallow the fluid, please seek medical attention immediately
CAUTION
- Keep the machine dry at all time. The machine is not waterproof, do not expose the machine to water, rain, or moisture environment.
- Please make sure the power outlet is not damaged or loose before plug in the power cord.
- If the power cord is damaged, it must be replaced by Antari or its local dealers, otherwise the warranty will be void.
- Before operating the machine, please sure the fluid is filled in the fluid tank to avoid the pump in idling state which could lead to overeat or malfunction.
- Before transporting the machine, please make sure the fluid is drained and tank is empty. (Recommend using original package)
- The machine is for indoor use only.
- Do not operate the machine in any area with unstable voltage.
- If you experience strange sound or malfunction, turn off the power and unplug the power cord immediately and contact your local Antari dealer for assistant.
- Do not contact any moving part.
- Only use accessories recommended or sold by Antari.
- Please make sure the power is off when not using the machine and unplug the power cord if not intend to use for a long period of time.
- To disconnect, turn all controls to the off position, then remove plug from outlet.
- Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
- Unplug from outlet before servicing or cleaning.
- Do not operate the machine with a damaged cord or plug, or after the machine malfunctions or is dropped or damaged in any manner. Return machine to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment.
- To ensure the lifespan of the machine, please only use the fluid manufactured by Antari, do not use other fluid or additive, otherwise it may clog the heater and cause malfunction.
Before operating the machine, please read all warning labels on the machine, description as below:
Top Cover Printing
WARNING!
HOT NOZZLE!
KEEP AT LEAST 50 CM DISTANCE
Rear Cover Printing
WARNING!
DISCONNECT POWER BEFORE CHANGING FUSE USE ONLY WITH ADULT SUPERVISION DO NOT
OPERATE WITHOUT LIQUID FOR INDOOR USE ONLY. KEEP DRY NO USER SERVICEABLE PARTS
INSIDE
LIQUID
ONLY USE MANUFACTURER DESIGNATED FLUID
ATTENTION!
NEVER ADD FLAMMABLE SUBSTANCES
Package Contents & Inspection
Immediately upon receiving the machine, carefully unpack the carton, check the content to ensure it is the correct model and all parts are included. If any part appears to be damaged or missing during transportation, please contact your local dealer and return with original package for inspection.
Package Contents
1 x Z-800 III Fog Machine
1 x Power Cord
1 x Z-10 Cable Remote
1 x User Manual or Scan QR Code on the Machine
Optional Accessories
Item Code | Description |
---|---|
Z-40 | Cable Timer Remote |
Z-50 | Wireless Remote |
Machine Details
01. Fog Nozzle | 05. Power Switch |
---|---|
02. Button | 06. Fuse |
03. Handle | 07. Power Input |
04. Tank Cap | 08. Cable Remote Connector |
Technical Label Information
Please read the technical label information on the back of the machine before operating it.
1. Model Name| 5. Breaker / Fuse
2. Input Voltage| 6. QR CODE for User Manual
3. Frequency| 7. Serial No.
4. Rated Power|
Fog Liquid
CAUTION!
Always turn off the power before filling the fluid tank. Do not add
flammable liquid to the fluid tank. If fluid gets inside the machine, please
contact your local Antari dealer for assistant.
- Only the fog liquid manufactured by Antari can be used, do not mix or dilute the fog liquid. Due to improper storage or using other fluid might clog the heater and cause malfunction.
- The machine is tested and calibrated with the specific fog liquid to get the best performance.
- Please empty the fluid in the tank before switching to another fluid to avoid mixing.
- Only the essence manufactured by Antari can be used, and add according to the ratio recommended by Antari (Recommended ratio is 1:1000), if using other essence or different ratio might clog the heater and cause malfunction.
- The warranty on your fog machine will be void if you use fog liquid other than recommended by the Antari of your smoke machine.
Setting and Manual Operation
WARNING
Machine falling off might cause serious injury, please make sure it is secure
and firm on the overhead.
Step 1. Place the machine on a flat, level hard and well ventilated
surface area and reserve at least 50cm open space around the machine, and make
sure there is no flammable gas or material nearby;
Step 2. Fill the fluid tank with Antari approved fog liquid, and make
sure the tube is not twisted;
Step 3. Plug the machine to the power outlet. Please read the technical
label on the back of the machine and make sure the power outlet has the
correct rated voltage for the machine;
Step 4. Turn on the power, the machine starts to warm up and the button
on the handle will show red blinking light. The warming process takes
approximately 2 minutes. Once the machine has reached its operating
temperature, the red blinking light will turn solid. Now the machine is ready
for operation;
Step 5. To start fogging, please press the button on the handle. To stop
fogging, please release the button the handle;
Step 6. To turn off the power, please make sure the machine is not
operating. If you will not use the machine a long period of time, please
unplug the power cord.
Control Settings
Z-800 III Fog Machine can be operated in the following modes. The machine can only accept 1 type of signal at a time. When using different control modes at the same time, the machine will work according to built-in control priority:
- Manual
- Timer
- Cable Remote
- Wireless
Machine Status
Indicator Light Description
No. | Status | LED Indicator Light | Remote Indicator Light | Buzzer |
---|---|---|---|---|
1 | Thermal Line Off | Blink Twice Every 3 Sec. | Blink Twice Every 3 Sec. |
Simultaneous Beep
2| Thermal Line
Reverse
| Blink 3 Times Every 3 Sec.| Blink 3 Times Every 3 Sec.| Simultaneous Beep
3| Heater Error| Blink 4 Times Every 3 Sec.| Blink 4 Times Every 3 Sec.| N/A
4| Heater Overheat| Continuously Fast Blink| Continuously Fast Blink| N/A
5| Warm Up| Continuously Slow Blink| Continuously Slow Blink| N/A
6| Warm Up Complete| Constant Light| Constant Light| N/A
7| Wrong Voltage| N/A| N/A| Continuously Beep
Z-10 Cable Remote (Standard)
Z-10 Cable Remote is a standard accessory for Z-800 III Fog Machine, please see instruction below;
- Plug the cable remote to the connector on the back of the machine;
- When the green indicator light is solid, it’s ready to fog;
- Press the red button to start fogging and release the red button to stop fogging.
** If you encounter any problem, please contact your local Antari dealer for assistant.
Z-40 Timer Cable Remote (Optional)
Z-40 Timer Cable Remote is an optional accessory for Z-800 III Fog Machine, please see instruction below;
- Plug the timer cable remote to the connector on the back of the machine;
- Press the RED button to turn on the power of the remote (Red Indicator Light is on) and Press the RED button again to turn off the power (Red Indicator Light is off);
- Press the YELLOW button to turn on the TIMER function (Yellow Indicator Light is on), then you can turn the DURATION and INTERVAL knob according to your needs. Press the YELLOW button again to turn off the TIMER function (Yellow Indicator Light is off);
- Press the GREEN button to start fogging (Green Indicator Light is on) and Press the GREEN button again to stop fogging (Green Indicator Light is off).
Note:
- You must turn on the power of the remote in order to use it.
- If the TIMER function is off, you can still press the Green button to start fogging.
- The “DURATION” and “INTERVAL” knob are using analog signal, therefore can’t define a specific time range.
- If you encounter any problem, please contact your local Antari dealer for assistant
Z-50 Wireless Remote (Optional)
Z-50 Wireless Remote is an optional accessory for Z-800 III Fog Machine, it included a wireless remote control and a receiver. It’s ready to use, no pairing necessary, please see instruction below;
- Plug the receiver to the connector on the back of the machine;
- Press either RED button to start fogging and release the RED button to stop fogging.
Signal range is approximately 50m in open area, it may vary depending on actual situation on site.
If you encounter any problem, please contact your local Antari dealer for assistant.
Service and Maintenance
DANGER!
Disconnect the power cord before starting maintenance operation!
- Always keep the machine clean.
- Can use an air compressor, a vacuum or a soft brush to remove the dust on the machine.
- Can use a slightly damp cloth to clean the casing.
- Before store the machine, please make sure the machine is completely cool down to avoid moisture inside the machine causing malfunction.
- It is recommended to run the machine at least once a month in order to maintain its best performance and output condition.
- Excessive dust and build up liquid residue will reduce the performance and cause overheat
Technical Specifications
Z-800 III
Input Voltage| US Model : AC 100 – 120V, 50 / 60 Hz 7.0A
EU Model : AC 220 – 240V, 50 / 60 Hz 3.5A
Rated Power| 800W
Warm-Up Time| 2 minutes (approx.)
Fluid Consumption| 13 ml/min (100% output)
Fluid Tank Capacity| 0.8 Liters (0.21 gallon)
Compatible Fluid| Antari FLG Heavy Fog Fluid、Antari FLR Light Fog Fluid
Ambient Temp. Range| 0°C – 40°C (32°F – 104°F)
Control Methods| Manual、Timer (Optional)、Cable Remote
(Standard)、Wireless (Optional)
Interface| N/A
DMX Channel| N/A
Included Accessories| Z-10 Cable Remote
Optional Accessories| Z-40 Timer Cable Remote、Z-50 Wireless Remote
Dimension| L 315 W 128 H 218 mm (L 12.40 W 5.04 H 8.58 inch)
Weight| 4.2 kg (9.26 lbs.)
Warranty Disclaimer
We guarantee the merchandise manufactured by us to be free from defect in material and workmanship for a period of one year. Our obligation and liability under this warranty shall be restricted to repair or replacement at our factory or local authorized dealer. We assume no liability of the products that are improperly used or used for any purpose other than that for which they are specially designed. This warranty shall not apply to any merchandise which has been repaired, altered or assembled outside our factory in any way so as in our judgment to affect its performance, nor which has been subjected to misuse, negligence, or accident nor to any merchandise operated contrary to our printed instructions. We will not allow or be liable of any loss or any damages of any kind in connection with the use, sale, or repair of any merchandise purchased from us.
Machine Dimension
Appendix I – Grounding Instruction
This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipment grounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120V circuit, and has a grounding plug that looks like the plug illustrated in sketch A in Figure. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by the metal screw.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>