Kwikool KAM14 AtticMaster Portable Air Conditioner User Manual
- June 12, 2024
- KwiKool
Table of Contents
Kwikool KAM14 AtticMaster Portable Air Conditioner
The Kwikool AtticMaster Portable Air Conditioner is designed to move conditioned air up to 90’ into a hot ambient environment in order to provide spot cooling. The specially made insulated duct is guaranteed not to form condensation on the outside of the duct. The outside duct covering has air holes, which allow it to be easily compressed back into its carry bag.
Product Control Panel
- OFF
- FAN (LOW 300)
- ON
- COOL (HIGH 900)
Product Components
- Duct Clamp
- 30 Foot Duct
- Condensate Tank
- On/Off Switch
- Fan/Cool Switch
- High/Low Switch
- Utility Handle
- Hot Air Exhaust
- 8 Inch Rear Wheels
- Front Swivel Wheels
Product Quick Start Procedure
- Select the location to set up your system. Make sure all four sides of your unit are clear and not blocked in any way that would restrict airflow.
- Remove the 30′ duct from its storage bag. Attach the duct clamp to the steel ring on top of the unit. Make sure the clamp is as tight as it can be and run eyelets into the ring.
- Squeeze the duct end loop and insert it into the first duct end loop. A maximum of three 30-foot lengths of duct can be used for a total maximum length of 90 feet. At least one 30-foot length must be connected to the unit for proper back pressure.
- KAM1411 requires a 115 Volt outlet. Only use a dedicated 115 Volt / 15 Amp circuit, such as the outlet for a washing machine.
Product Operating Procedure
- Turn on the power outlet.
- Select the desired mode (FAN or COOL) and fan speed (LOW or HIGH) using the control panel.
- Place the duct opening within 5′ of the person being cooled for effective use.
Changing the Filter
Cleaning the KAM1411 return air filter is as easy as 1-2-3. Kwikool Attic Master Systems have a washable and reusable filter. This filter should be removed and cleaned periodically. When the system is not in operation, disconnect the power before removing the filter. The KAM1411 AtticMaster filter size is 12 x 12 x 1 (LxWxD).
- Remove the filter by easily loosening the two fasteners shown. Use a flathead screwdriver.
- Raise the filter up; it should easily slide out of the pocket.
- Clean the filter by rinsing it with water or blow it out using a compressed gas. Do not use excessive pressure when doing so. Allow the filter to dry completely before reinstalling it.
Important Details
This manual can be found online at atticmaster-manual.com. Kwikool manufactures excellent commercial portable cooling equipment in the U.S.A. For more information, please contact sales@kwikool.com or call 800-Kwikool.
Read this manual carefully before installing and using your KwiKool Portable
Cooling System. This concise manual offers effective and proper usage
instructions, including safeguards for the most effective practice. Retain
this manual for future reference.
You can access the whole manual online. atticmaster-manual.com
COMPONENTS
- Duct Clamp
- 30 Foot Duct
- Condensate Tank
- On/Off Switch
- Fan/Cool Switch
- High/Low Switch
- Utility Handle
- Hot Air Exhaust
- Inch Rear Wheels
- Front Swivel Wheels
Introduction To The KAM1411
The KwiKool AtticMaster is designed to move conditioned air up to 90’ into a hot ambient environment in order to provide spot cooling. The duct opening must be placed within 5’ of the person being cooled for effective use. The specially made insulated duct is guaranteed not to form condensation on the outside of the duct. The outside duct covering has air holes, which allow it to be easily compressed back into its carry bag.
QUICK START PROCEDURE
Select The Location To Set Up Your System Make sure all four sides of your unit are clear, and not blocked in any way that would restrict air flow. Remove The 30’ Duct From Its Storage Bag Attach the duct clamp to the steel ring on top of the unit. Make sure the clamp is as tight as it can be and run eyelets into the ring.
Attaching Extra 30 Foot Duct Length
- Squeeze the duct end loop and insert into first duct end loop.
- A maximum of three 30 foot lengths of duct can be used for a total maximum length of 90 feet.
- At least one 30foot length must be connected to the unit for proper back pressure.
Power Outlet
- KAM1411 requires a 115 Volt outlet. Only use a dedicated 115 Volt / 15 Amp circuit, such as the outlet for a washing machine.
OPERATING PROCEDURE
AtticMaster Controls
- The AtticMaster controls are located on the top right side on the front of the unit. There are 3 switches (See Unit Components).
On/Off Switch
- 2-position switch, turns unit on or off.
Fan/Cool Switch
- 2-position switch, turns unit fan only on or fan with compressor on.
Low/High Switch
- 2-position switch, turns the fan from low speed for use with a 30’ duct or high for use with a 60’/90’ duct.
Condensate Float Tank
- A condensate tank with a float switch is located in the front lower compartment of the unit. When the tank is full a beeping alarm will sound.
- When removing the tank, unplug the float jack. When replacing the tank make sure that the drain line is in the tank and the float jack is plugged in.
CHANGING THE FILTER
Cleaning The KAM1411 Return Air Filter Is As Easy As 1-2-3 KwiKool Attic Master Systems have a washable and re-useable filter. This filter should be removed and cleaned periodically. When the system is not in operation. Disconnect the power before removing the filter. The KAM1411 AtticMaster filter size is 12” x 12” x 1” (LxWxD).
Step 1
- Remove the FIlter by easily loosening the two fasteners shown. Use a Flathead screwdriver.
Step 2
- Next, raise the filter up, it should easily slide out of the pocket.
Step 3
- Clean the filter by rinsing it with water or blow it out using a compressed gas.
- Do not use excessive pressure when doing so. Allow the filter to dry completely before re-installing it.
IMPORTANT DETAILS
The System Must Stay Upright
Always keep the unit in an upright position, do not lay it on its side. If it happens that your portable cooling system is found in this circumstance, placed on its side, turn it upright and don’t power it up for at least four hours – or compressor damage could occur, due to oil displacement.
Keep Your Filters Clean
Filters should be changed as needed or at least once every two months. Follow the instructions for removing and cleaning the filter. The filter size is 12” x 12” x 1” (LxWxD)
If The Unit Sounds An Alarm
If the air flow is blocked from the intake or exhaust grills, it is possible, an alarm will sound, due to high pressure on the compressor. If this occurs, press the high-pressure reset button on the back of the unit, which will clear the alarm. Then place the unit is a location where it has plenty of space all around for clear airflow.
More Information
This manual can be found online
Manufacturing Excellence
KWIKOOL Manufactures
- Excellent Commercial
- Portable Cooling Equipment
- IN THE U.S.A.
- 1-800-KWIKOOL
- (594-5665)
- KWIKOOL.COM
More Products
FAMILY OF PRODUCTS
Documents / Resources
|
Kwikool KAM14 AtticMaster Portable Air
Conditioner
[pdf] User Manual
KAM14 AtticMaster Portable Air Conditioner, KAM14, AtticMaster Portable Air
Conditioner, Portable Air Conditioner, Air Conditioner, Conditioner
---|---
References
- Attic Master Manual – Attic Master Manual | Portable Cooling with High Static Air Flow – The Attic Master offers a quick and easy cooling solution for hard to reach and challenging spaces
- Portable Cooling Systems, Air Conditioners, High-capacity AC
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>