QSFPTEK S7600-48X8C 48-Port 10Gb Ethernet L3+ Switch User Guide

June 12, 2024
QSFPTEK

QSFPTEK S7600-48X8C 48-Port 10Gb Ethernet L3+ Switch

QSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig-
\(2\)

The S7600-48X8C is a high-performance 10G/100G switch. The product position is to meet the requirements of next-generation enterprise, data center, Metro, and HCI (Hyper-ConvergedInfrastructure) networks.

Accessories

  • AC power cord
  • SFP+ module
  • QSFP28 module
  • Fiber patch cable
  • Console cable
  • Flathead screwdrivers
  • Phillips screwdrivers
  • ESD-preventive wrist strap

Hardware Overview

The S7600-48X8C has 48x 10G SFP+ ports and 8x 100G QSFP28 uplinks. It supports MLAG.

Front Panel Ports

Ports Description
SFP+ Ports for 1G/10G connection
QSFP28 Ports for 40G/100G connection

Back Panel Ports

Ports Description
CON An RJ45 console port for serial management
ETH An RJ-45 Ethernet management port
USB A USB management port for software and configuration backup and

offline software upgrade

Front Panel LEDs

LEDs Status Description
ID SYS ETH Blue: On ID indication function enable, Off ID indication

function disable
Green: On The system is normal running
Amber: On The system occur alarm or error.
Off: No power or System is not run or abnormality
SFP+ (Port 1-48)| Green: On Port link, Off Port not link
Green: On 10G port link, Blinking 10G packets receiving or
transmitting
Amber: On 1G port link, Blinking 1G packets receiving or
transmitting
Off: Port not link
QSFP28 (Port 49-56)| Green: On 100G/40G port link, Blinking 100G/40G packets
receiving or transmitting
Amber: On 10G/1G port link, Blinking 10G/1G packets receiving or
transmitting
Off: Port not link
Loop Blinking: One or more 100G/40G ports are breakout
Off: None of the 100G/40G port is breakout

Installation Requirements

Tools Preparation

  • Flathead screwdrivers
  • Phillips screwdrivers
  • ESD-preventive wrist strap

Temperature/Humidity Requirements

Temperature: 10%-95%

Cleanliness Requirements

  • Substance: DUST SO2 H2S NH3 Cl2
  • Concentration limit:
    • Particle/m3: 3 X 104 (No visible dust on the tabletop for three days)
    • mg/m3: 0.2
    • mg/m3: 0.006
    • mg/m3: 0.05
    • mg/m3: 0.01
  • Note: The dust particle size is 5 m

Mounting the Switch

To mount the switch:

  1. Choose a suitable location for the switch.
  2. Use the flathead and Phillips screwdrivers to install the switch onto a rack or a flat surface.

Connecting the Power

To connect the power:

  1. Plug the AC power cord to the switch power port on the back rear.
  2. Connect the other end of the power cord to an AC power source equipment.

Connecting the SFP+ Port

To connect the SFP+ port:

  1. Insert the SFP+ module into the SFP+ port.
  2. Plug a fiber patch cable to the SFP+ transceiver.
  3. Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the QSFP28 Port

To connect the QSFP28 port:

  1. Insert the QSFP28 module into the QSFP28 port.
  2. Plug a fiber patch cable to the QSFP28 transceiver.
  3. Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the Management Ports

Connecting the Console Port

To connect the console port:

  1. Prepare a console cable.
  2. Insert the RJ45 connector of the console cable into the console port on the switch.
  3. Connect the D89 female connector on the other end of the console cable to the serial port on the computer host.

Introduction

  • The S7600-48X8C is a high-performance 10G/100G switch. The product position is to meet the requirements of next generation enterprise, data center, Metro and HCI (Hyper-Converged Infrastructure) networks.
  • We appreciate your decision to select S7600-48X8C. This manual is intended to help you become acquainted with the switch design and provide instructions for implementing the switches into your network.QSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig- \(3\)

Accessories

QSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig-
\(4\)

Hardware Overview

Front Panel PortsQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig-
\(5\)

Ports Description
SFP+ SFP+ ports for 1G/10G connection
QSFP28 QSFP28 ports for 40G/100G connection

Back Panel PortsQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig-
\(6\)

Ports Description
SFP+ SFP+ ports for 1G/10G connection
QSFP28 QSFP28 ports for 40G/100G connection

Front Panel LEDsQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig-
\(7\)

LEDs Status Description

ID

| ****

Blue

| On| ID indication function enable
Off| ID indication function disable



SYS

| Green| On| The system is normal running
Amber| On| The system occur alarm or error.
–| Off| No power or System is not run or abnormality


ETH

| ****

Green

| On| Port link.
Off| Port not link.




SFP+ (Port 1-48)

| Green| On| 10G port link.
 | Blinking| 10G packets receiving or transmitting.
Amber| On| 1G port link.
 | Blinking| 1G packets receiving or transmitting.
–| Off| Port not link




QSFP28 (Port 49-56)

| Green| On| 100G/40G port link.
 | Blinking| 100G/40G packets receiving or transmitting.
Amber| On| 10G/1G port link.
 | Blinking| 10G/1G packets receiving or transmitting.
–| Off| Port not link


Breakout

| Loop Blinking| One or more 100G/40G ports are breakout
Off| None of the 100G/40G port is breakout

Back PanelQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig-
\(8\)

Installation Requirements

Tools Preparation

  • Flathead screwdrivers
  • Phillips screwdrivers
  • ESD-preventive wrist strap

Temperature/Humidity Requirements

Temperature Humidity
0~45°C 10%~95%

Cleanliness Requirements:

Substance Unit Concentration limit
DUST Particle/m3 ≤ 3 X 104 (No visible dust on the tabletop for three days)
SO2 mg/m3 0.2
H2S mg/m3 0.006
NH3 mg/m3 0.05
Cl2 mg/m3 0.01

Note: The dust particle size is ≥ 5 μm

Mounting the Switch

Connecting the PowerQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-
fig- \(9\)

  1. Plug the AC power cord to the switch power port on the back rear.
  2. Connect the other end of the power cord to a AC power source equipment.

Connecting the SFP+ PortQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3
-Switch-fig- \(10\)

  1. Insert the SFP+ module into the SFP+ port.
  2. Plug a fiber patch cable to the SFP+ transceiver.
  3. Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the QSFP28 PortQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3
-Switch-fig- \(11\)

  1. Insert the QSFP28 module into the QSFP28 port.
  2. Plug a fiber patch cable to the QSFP28 transceiver.
  3. Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the Management Ports

Connecting the Console PortQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3
-Switch-fig- \(12\)

  1. Prepare an console cable.
  2. Insert the RJ45 connector of the console cable into the console port on the switch.
  3. Connect the D89 female connector on the other end of the console cable to the serial port on the computer host.

Connecting the ETH PortQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3
-Switch-fig- \(13\)

  1. Prepare an standard RJ45 Ethernet patch cable.
  2. Insert one end of the RJ45 Ethernet patch cable to the computer RJ45 port.
  3. Connect the RJ45 connector on the other end of the patch cable to the ETH port on the switch.

Connecting the USB PortQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3
-Switch-fig- \(14\)

  1. Prepare an Universal Serial Bus (USB) flash disk.
  2. Insert the USB to the switch USB port.

Configuring the Switch

Configuring the Switch Using the Web-based Interface

  • Step 1: Connect your computer to the switch using an Ethernet cable and open a web browser.
  • Step 2: Set the IP address of the computer to 192.168.1.x (where “x” is any number from 2 to 254) and the subnet mask to 255.255.255.0.QSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig- \(15\)
  • Step 3: Open a web browser and type http://192.168.1.2 in the address bar. Enter the default username and password (admin/admin).
  • Step 4: Click sign-in to access the web-based configuration page.

Configuring the Switch Using the Console Port

  • Step 1: Use the console cable to direct connect the switch console port to your computer.
  • Step 2: Launch the terminal simulation software such as HyperTerminal on the computer.
  • Step 3 : Configure the parameters of the terminal emulation software as follows: 115200 bits per second, 8 data bits, no parity, 1 stop bit, and no flow control.QSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig- \(16\)
  • Step 4 : Enter the default username and password (admin/admin).

Troubleshooting

Loading Failure Processing:

After loading fails, the system will keep running in the original version. At this time, users should refer to the following steps to re-check:

  1. if physical port connections are good first. If some ports are not connected, then re-connect them to ensure that physical connections are correct, and begin re-loading.
  2. If physical connections are correct, then check the loading process information displayed on the super terminal to verify if there are input errors. If there are input errors, correct them and re-load. For example, when using TFTP protocol, we enter incorrect IP addresses of the Server and Switch, name of loading software, do not specify the correct working path of the correct TFTP server, and so on.
  3. if physical connections are good, and there are no input errors in the loading process but the loading fails finally, please contact agents for help.

User Password Lost:
If the system password is lost or forgotten, the following method can be used to reset the password:

  1. Enter uBoot operation mode; see Chapter 5 for how to enter;
  2. Input boot_flash_nopass command to start the system in uBoot mode;

Note : After using the boot_flash_nopass command, the system will clear up the startup-config files; before starting this operation, the startup- config files will be stored in flash:/startup-config.conf.old file.

Power System Troubleshooting:

The switch can judge if its power system is faulty according to the PWR indicator on the front panel: when the power system works normally, the PWR indicator shall always keep lighting; when the PWR indicator is off, please check if:

  1. The power line of the switch is connected correctly.
  2. The EPS of the switch matches the power required by the switch.

Configuration System Troubleshooting:
After the switch is powered on, if the system is normal, the startup information will be displayed on the configuration terminal; If no display information on the configuration terminal appears, maybe the configuration system is faulty, please check if:

  1. The power is normal.

  2. The cable of the configuration port (Console) is properly connected.
    If no problems have been found after the above checks, it is possible that the configuration cable is faulty or the parameter setting of the terminal (such as a super terminal) is incorrect, please check accordingly.

  3. Troubleshooting for the terminal displaying hashes:
    If the configuration terminal displays hashes, it is probable that the parameter setting of the terminal (such as a super terminal) is incorrect Please confirm the parameter setting of the terminal (such as HyperTerminal): baud rate: 115200, data bit: 8, parity: no, stop bit: 1, flow control: NA, selecting terminal emulation: VT100.

Support and Other Resources

Product Warranty

S7600 series switches are backed by a 5-year limited warranty supported by QSFPTEK. And you are eligible to apply for a return or exchange of your items within 14 days of receiving them.
For more details about applying qualifications, please live chat or email [email protected] for supportQSFPTEK-S7600-48X8C-48-Port-10Gb-Ethernet-L3-Switch-fig-
\(17\)
www.qsfptek.com