UNI-T UTi120S Thermal Imaging User Manual

June 4, 2024
UNI-T


UTi120S Thermal Imaging
User ManualUNI T UTi120S Thermal Imaging

UTi120S
Professional Thermal Imager User Manual

Preface
Thank you for purchasing the new U111205 thermal imager. In order to use this product safely and correctly. please read this manual thoroughly. especially the Safety Instructions part.
After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
Limited Warranty and Liability
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination or improper handling. The dealer shall not be entitled to give any other warranty on behalf of UM-Trend. If you need warranty service within the warranty period, please contact your seller directly.
Uni-Trend will not be responsible for any special. indirect, incidental or subsequent damage or loss caused by using this device.

Specifications

Sensor Uncooled infrared focal plane thermal imaging sensor
Pixel size 17 pm
Infrared spectrum bandwidth 8-14pm
Thermal imaging pixels 10800 (120’90)
Thermal imaging sensitivity <60mK
Field of view (FOV) 50°(H) x 38°(V)
Spatial resolution (IFOV) 7.6 mrad
Rate 25Hz
Minimum imaging distance 0.1m
Focus Focus-free
Temperature range -20°C – 400°C
Accuracy ±2°C or ±2%, whichever is greater (-10°C -400°C room temperature

25°C)
Measurement units| °C/°F
Resolution| 0.1°C
Emissivity| 0.95 (default) 0.01 – 0.99
Temperature display| Center point temperature, high/low-temperature tracking
Palettes| lava, rainbow HC, black hot , white hot, iron, Rainbow
Display type| 2.4″ TFT LCD
Display resolution| 320 x 240
Buttons| 4 buttons (power, up, down, OK) 1 trigger
---|---
Laser| 4(Class 2)
LED Light| 4
Temperature alarms| LCD, LED, buzzer
Image storage| Micro SD Card
Image format| BMP
PC analysis software| 4
USB communication| Type-C USB
Battery| Li-ion 3.7V/2600mAh 18650
Operating time| Continuous operating time >9h
Charging time| s2.5h
Charging voltage/current| 5V 12A
Power on speed| Os (wake up) / 5s (power on)
Auto power off| 5min/10min/30min(default)/off
Operating temperature| 0 – 50°C ( 32 -140°F )
Storage temperature| -20 – 60°C ( -4 – 140°F )
Operating humidity| < 85%RH ( Operating humidity )
IP rating| IP54
Drop-proof| 2m
Product size (LxWxH)| 197 x 72 x 60 mm
Product weight| 310g
Certificates| CE, UKCA, RoHS
Accessories| User manual, Type-C USB cable, 32GB Micro SD card

Structure

UNI T UTi120S Thermal Imaging - Device 18

Item Description Item Description
1 Upper housing 9 Infrared camera lens
2 Interface protection cover 10 Image capture/trigger
3 Lower housing 11 LCD
4 USB Type-C interface 12 OK
5 SD card slot 13 Up
6 Bracket screw hole 14 Power / Back
7 Laser emission aperture 15 Down
8 LED light

LCD Indicators/Icons
Display size: 2.4″ (495mm 377mm) Display resolution: 320 (vertical) x 240 (horizontal)

UNI T UTi120S Thermal Imaging - Device 17

Item Description
1 Center point temperature
2 Center point
3 Lowest temperature spot
4 Date and time
5 Battery status
6 Temperature Bar
7 Highest temperature spot

Power On/Off
When the thermal imager is not turned on, long press the power button for as to power on. When the thermal imager is in the suspend state, short press the power button for 1s to power on.
When the thermal imager is turned on, short press the power button for 1s to enter the suspend state. Long press the power button for 8s, “power off’ will show on the screen, and the thermal imager will be turned off.
Menu
Short press the OK button to enter the menu interface. Short press the Back button to return to the upper menu. Short press the trigger to directly return to the main interface of the thermal imager.

Image View
In the menu, select Image View, and then short press the OK button to enter the image viewing interface Press the Up/Down button to select an image. Press the OK button twice to view the Picture Info or Delete images.

UNI T UTi120S Thermal Imaging - Device 15

Temperature Mark
In the menu, short press the Up/Down button to select Temper Mark, and then short press the OK button to enter the temperature mark interface. Center Point/ Hi/Lo Point/Palette/Date&Time can be set in this interface. For example, select Center Point, and then press the OK button to turn on/off this function.

UNI T UTi120S Thermal Imaging - Device 14 HMO Alert
In the menu, short press the Up/Down button to select HULO Alert, and then short press the OK button to enter the alert setting interface. Temper Alert, Buzzer, HI Alert, and LO Alert can be set in this interface.

UNI T UTi120S Thermal Imaging - Device 13

LED light
In the menu, short press the Up/Down button to select Hand Light, and then short press the OK button to turn on/off the flashlight.

UNI T UTi120S Thermal Imaging - Device 16

Palette
In the menu, short press the Up/Down button to select Palette, and then short press the OK button to enter the palette selection interface. Short press the Up/Down button to step through six palettes: Rainbow, Iron, White Hot, Black Hot, Rainbow HC, Lava, and short press the OK button to confirm the selected palette.\

Language
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. Select Language, and short press the OK button to switch between English/Chinese

UNI T UTi120S Thermal Imaging - Device 9

Temperature Unit
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/Down button to select Temper Unit, and short press the OK button to switch between`C/T.

UNI T UTi120S Thermal Imaging - Device 7 Emissivity
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Emissivity, and short press the OK button to set the emissivity.

Laser
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Laser, and short press the OK button to turn on/off the laser.

UNI T UTi120S Thermal Imaging - Device 8

Time & Date
In the menu, short press the Up/Down button to soled Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button  o select Time&Date, and short press the OK button to enter the setting interface. The Time Format can switch between 12H and 24H. Press the Up/Down button to adjust the value of time and date, and short press the OK button to confirm.

UNI T UTi120S Thermal Imaging - Device 6

Brightness
In the menu, short press the Up/Down button to select Betting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to Speed Brightness, and short press the OK button to enter the setting interface. The brightness can be Low, Middle or High.

UNI T UTi120S Thermal Imaging - Device 3

Auto Power Off
In the menu, short press the Up/Down button to soled Setting~ and then short press the OK button to enter the submenu. In the submenu~ short press the Up/ Down button to select Auto Power Off, and short press the OK button to enter the setting interface. In mis interface, users can set the auto power off time (5/ 10/3Omin) or tum off the auto power-off function.

UNI T UTi120S Thermal Imaging - Device 5

Auto Save
In the menu, short press the Up/Down button to soled Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Auto Save. Short press the OK button to tum on/off the auto-save function.

UNI T UTi120S Thermal Imaging - Device 4

Format SD
In the menu~ short press me Up/Down button to select Sanding, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down bunch to select Format SD and short press the OK bunch to enter the saning interface Press ma OK bunch salad Yes or No.

UNI T UTi120S Thermal Imaging - Device 2

Device Info
In my menu, short press the Up/Down bunch to select Sanding, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down bunch to select Device Info and short press the OK button to enter the info mum viewing interface. The device information including Code, Firmware, Capacity, and Available can be viewed.

UNI T UTi120S Thermal Imaging - Device

Factory Reset
In the menu, short press the Up/Down bunch to select Sanding, and then short press the OK bunch to enter the submenu. In the submenu, short press the Up/ Down bunch to select Factory Reset and short press the OK bunch to enter the setting interface. Press the OKand  bunch select Yes or No.

UNI T UTi120S Thermal Imaging - Device 1

USB Communication and PC Analysis Software

  1. Please refer to the instructions to download and install the PC software.
  2. Connect the USS data cable to the computer. Users can view images and analyze data via the PC software.
  3. To use the PC software correctly, please read the Software User Manual.
  4. During USS communication, do not directly unplug the USS cable. If users want to disconnect the device when it has been successfully connected to the computer, they can select Remove Device in the lower right corner of the

Maintenance

Use a wet cloth or weak soap solution to dean the outer shell of my device. Do not use abrasive isopyl or solvents toclean the shell.lens or windos.
Safety Instructions
In order to ensure measurement accuracy, please read the instructions carefully. Please use this product in accordance with the user manual. Ot,herwise the free warranty will not be carried out if the product is damaged. Please do not use this product in flammable, explosive, steamy, humid or corrosive environments. Please do not continue to use the product when it is damaged, dropped or corrected, so as to avoid erroneous measurement results. Please refer to the emissivity to get the actual temperature. Otherwise, the measured temperature will be inaccurate. Charging will cause the internal temperature of the machine to rise, thereby affecting the measurement accuracy. Therefore, it is recommended not to take measurements when charging the product.
Appendix

Material

| Emissivity| Material|

Emissivity

---|---|---|---
Wood| 0.85| Black paper| 0.86
Water| 0.96| Polycarbonate| 0.8
Brick| 0.75| Concrete| 0.97
Stainless steel| 0.14| Copper oxide| 0.78
Adhesive tape| 0.96| Cast iron| 0.81
Aluminum plate| 0.09| Rust| 0.8
Copper plate| 0.06| Gypsum| 0.75
Black aluminum| 0.95| Paint| 0.9
Human skin| 0.98| Rubber| 0.95
Asphalt| 0.96| Soil| 0.93
PVC plastic| 0.93| |

****UNETREND TECHNOLOGY (CHINA) CO., LTD.
Songshan Lake National High-Tech Industrial LG
Development Zone, Dongguan City,
Guangdong Province, China

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

UNI-T User Manuals

Related Manuals