QSFPTEK S7300-48X2Q4C Switch User Guide
- June 12, 2024
- QSFPTEK
Table of Contents
- QSFPTEK S7300-48X2Q4C Switch
- Product Information: S7300-48X2Q4C 48-Port 10G Ethernet L3+Switch
- Accessories
- Hardware Overview
- Installation Requirements
- Introduction
- Appearance Description for Standard Configuration
- Connecting the Management Ports
- Troubleshooting
- Support and Other Resources
- Product Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
QSFPTEK S7300-48X2Q4C Switch
Product Information: S7300-48X2Q4C 48-Port 10G Ethernet L3+Switch
The S7300-48X2Q4C is a high-performance switch with 48x 10G SFP ports, 2x 40G QSFP+ ports, and 4x 100G QSFP28 uplinks. It supports stacking and provides hot-swappable ports for easy installation and maintenance. The switch has LED indicators for power, system, management port, SFP+ port, QSFP+ port, and QSFP28 port.
Accessories
- Screwdriver
- Static armguard
- Bolt
- Ethernet cable
- Other Ethernet terminal devices
- Control terminal
Hardware Overview
S7300-48X2Q4C
The S7300-48X2Q4C switch has hot-swappable ports on the front and back panel:
Front Panel Ports
No. | Ports | Description |
---|---|---|
1, 4 | SFP+ | Hot-swappable SFP+ ports for 1/10G connection |
3 | QSFP+ | Hot-swappable QSFP+ ports for 40G connection |
2 | QSFP28 | Hot-swappable SFP+ ports for 40/100G connection |
Back Panel Ports
No. | Ports | Description |
---|---|---|
7 | CLI | An RJ45 console port for serial management |
6 | MNG | An RJ-45 Ethernet management port |
5 | USB | A USB management port for software and configuration backup and |
offline software upgrade
LEDs
The switch has several LED indicators on the front panel:
No. | LEDs | Name | Description |
---|---|---|---|
7, 8, 6, 9, 5, 1, 4 | System/power supply indicators | PWRA, PWRB, SYS | Power |
indicator A and B, system indicator. If the system
indicator flickers, the system works well. If the indicator is off
or always on, the system is abnormally started.
1-48(LINK/ACT)| SFP+ port indicators| LINK/ACT| If the indicator is always on,
the port is normally linked. If
the indicator is off, the port is not linked. If the indicator
flickers, there is data transmission.
1-2| QSFP+ port indicators| 40G| If the indicator is always on, the port is
normally linked. If
the indicator is off, the port is not linked. If the indicator
flickers, there is data transmission.
1-4| 40G/100G QSFP28 port indicators| | If the indicator is always on, the
port is normally linked. If
the indicator is off, the port is not linked. If the indicator
flickers, there is data transmission.
2 (40GE BREAKOUT 1-4)| 40GE BREAKOUT indicators| | The 40GE port breaks out
into 4 10GE ports. If the QSFP+ port
indicator is on, the four indicators of 40GE BREAKOUT correspond to
LINK/ACT state of the 4 10GE ports of the QSFP+ port.
Installation Requirements
Tool Preparation:
To install the switch, you will need the following tools:
- Screwdriver
- Static armguard
- Bolt
- Ethernet cable
- Other Ethernet terminal devices
- Control terminal
Tool Preparation:
- Put off ornaments, such as ring, necklace, watch and bracelet, before you operate under live working. When metal articles connect the power to the ground, short circuit happens and components may be damaged.
- Pull out the AC power socket and close the direct-current power before operating on the machine box or working beside the power source.
- When the power is on, do not touch the power.
- Correctly connect the device and the power socket.
- Only professionals are allowed to operate and maintain the device. Read the installation guide carefully before the system is powered on.
Site Environment:
- The switch can be installed on the desk or the cabinet.
- The location of the machine box, cabinet planning and indoor cabling are very important for normal system’s function.
- Short distance between devices, bad ventilation and untouchable control plate will cause maintenance problems, systematic faulty and breakdown.
Product Usage Instructions
To use the S7300-48X2Q4C switch, follow these steps:
- Connect the power supply A and B to the switch.
- Connect the Ethernet cable to the RJ45 console port or Ethernet management port on the back panel.
- Connect the other end of the Ethernet cable to the control terminal or other Ethernet terminal devices.
- If necessary, connect a USB cable to the USB management port for software and configuration backup and offline software upgrade.
- Connect your network devices to the SFP+, QSFP+, or QSFP28 ports on the front panel.
- Check the LED indicators on the front panel to ensure that the ports are properly linked and there is data transmission.
Introduction
The S7300-48X2Q4C is a high-performance full-10GE ToR switches. The product
position is to meet the requirements of next-generation Enterprise, Data
Center, Metro, and HCI (Hyper-Converged Infrastructure) networks.
The S7300 series switches provide a range of services, such as IPv6, VPN,
network security, flow analysis, and virtualization, to offer high-performance
L2/L3/L4 wire-speed switching capacity. To ensure maximum uptime, the series
employs reliable techniques like continuous forwarding, graceful restarting,
and loop network protection, all of which work seamlessly within the S7300
series fabric.
Appearance Description for Standard Configuration
No. | LEDs | Name | Description |
---|---|---|---|
7 | PWRA | Power indicator A | If the power supply A of the switch is |
powered on, the indicator is on.
8| PWRB| Power indicator B| If the power supply B of the switch is
powered on, the indicator is on.
6
|
SYS
| System indicator| If the system indicator fickers, the system works well. If the indicator is off or always on, the system is
abnormally started
9
|
MNG
|
Management port indicator
| If the indicator is always on, the port is normally linked. If the indicator is not on, the port is not linked.
If the indicator is off, the port is not linked.
If the indicator flickers, there is data transmisson.
5| LED| Indicator| System/power supply indicators
1, 4
| 1~48(LINK/A CT)| SFP+ port indicators| If the indicator is always on, the port is normally linked. If the indicator is off, the port is not linked.
If the indicator flickers, there is data transmisson.
3
|
40G 1~2
|
QSFP+ port indicators
| 1. working in the mode of 40GE
If the indicator is always on, the port is normally linked. If the indicator is off, the port is not linked.
If the indicator flickers, there is data transmission.
2. The 40GE port breaks out into 4 10GE ports
The 4 indicators turns on every 5 seconds by turns, which shows the 10GE port state of the BREAKOUT indicator.
2
|
40G/100G
1~4
|
QSFP28 port indicators
| 1. working in the mode of 100GE
If the indicator is always on, the port is normally linked. If the indicator is off, the port is not linked.
If the indicator flickers, there is data transmission.
2. working in the mode of 40GE
If the indicator is always on, the port is normally lined. If the indicator is off, the port is not linked.
| | | If the indicator flickers, there is data transmission.
3. The 40GE port breaks out into 4 10GEports
The 4 indicators turns on every 5 seconds by turns, which shows the 10GE port state of the BREAKOUT indicator.
---|---|---|---
2| 40GE BREAKOUT (1~4)| The 40GE port breaks out into 4 10GE port
indicators.| 1. Working in the mode of 40GE, the indicator of BREAKOUT is off
2. The 40GE port breaks out into 4 10GE ports, which combines with QSFP+ port indicators.
If the indicator of QSFP+ is on, the four indicators of 40GE BREAKOUT correspond to LINK/ACT state of the
4 10GE ports of the QSFP+ port
Back Panel
Temperature/Humidity Requirements:
Temperature | Humidity |
---|---|
0~45°C | 10%~95% |
Connecting the Power
- Plug the AC power cord into the power port on the back of the switch.
- Connect the other end of the power cord to an AC power source.
Connecting the SFP+/QSFP+/QSFP28 Ports
- Plug a compatible SFP+/QSFP+/QSFP28 transceiver into the SFP+/QSFP+/QSFP28 port.
- Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to another fiber device.
CAUTION: Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eve protection.
Connecting the Management Ports
Connecting the CLI Port
- Insert the RJ45 connector of the console cable into the RJ45 console port on the front of the switch.
- Connect the other end of the CLI cable to the RS-232 serial port on the computer.
Connecting the MNG Port
- Connect one end of a standard RJ45 Ethernet cable to a computer.
- Connect the other end of the cable to the MNG port on the front of the switch.
Connecting the USB Port
Insert the Universal Serial Bus (USB) flash disk to the USB port for software and configuration backup and offline software upgrade.
Configuring the Switch
Configuring the Switch Using the Web-based Interface
- Step1: Connect the computer to the Management port of the switch using the network cable.
- Step 2: Set the IP address of the computer to 192.168.0.2. Set thesubnet mask of the computer to 255.255.255.0.
-
- Step 3: Open a browser, type http://192.168.0.2, and enter the default username and password, admin/admin.
- Step 4: Click sign in to display the web-based configuration page.
Configuring the Switch Using the CLI Port
- Step 1: Connect a computer to the switch’s CLI port using the supplied CLI cable.
- Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
- Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8 data bits, no parity, 1 stop bitand no flow control.
- Step 4: Enter the default username and password, admin/admin.
Troubleshooting
Loading Failure Troubleshooting
If the loading process fails, the system will continue to operate in its
original state. In such a situation, users should first verify the physical
port connections to ensure they are properly connected. If some ports are
disconnected, reconnect them before attempting to reload the system. If the
physical connections are secure, the next step is to examine the loading
process information shown on the super terminal. If any input errors are
detected, they should be corrected before reloading the system.
User Password Lost Troubleshooting
If system password is lost or forgotten, the password can be reset using the
following method:
- Connect the console port of the switch to a computer using a console cable.
- Press “ctrl + b” to access the Uboot mode.Start the system with an empty configuration file with no password.
- Bootrom#boot_flash_nopass
- Bootrom#Do you want to revert to the default config file?[Y|N|E]:
NOTE : Forgetting your username and password and restoring them through console port may cause configuration loss and business interruption. Please remember your username and password.
Configuration System Troubleshooting
- Verify that the power supply is functioning correctly and that the console cable is appropriately connected.
- Confirm that the console cable is the appropriate type for the device being connected.
- Ensure that the control cable driver is appropriately installed on the computer.
- Verify that the settings of the HyperTerminal, such as baud rate, data bits, stop bits, and parity, are correctly configured.
Support and Other Resources
- Contct us https://www.qsfptek.com/company/contact-us.html
- Email sales@qsfptek.com
- Customer Successhttps://www.qsfptek.com/resources/customer-success-stories
- http://www.qsfptek.com
Product Warranty
S7300 series switches are backed by a 5-year limited warranty supported by
QSFPTEK. And you are eligible to apply for a return or exchange of your items
within 14 days of receiving them.
For more details about applying qualifications, please live chat or email
sales@qsfptek.com for support.
References
- Technical Documents - FS.com
- QSFPTEK - Compatible Optical Transceivers Factory Outlet
- QSFPTEK - Compatible Optical Transceivers Factory Outlet
- Customer Success Stories - QSFPTEK
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>