hansgrohe 40871000 AXOR STARCK Lighting Module

OTHER MODEL

Product description

The Axor Starck ShowerCollection light type 40871000 is a 12 V 3 W IP X5 built-in LED and is used to illuminate baths and showers.

Symbol description

Read the installation instructions
Beware of dangerous electrical current
  Important notice

Do not use silicone that contains acedic acid.

Dimensions
Spare parts
Assembly

**Repair**

Dimensions

Dimensions

Spare parts

Spare parts

Assembly

Assembly
Assembly
Assembly
Assembly
Assembly
Assembly
Assembly

Repair

Repair
Repair
Repair

**7**

Installation in reverse order, see page 62 Fig. 8 – 12


**Safety Notes

**

Intended Use

Light

The light type 40871000 is only suited for use in interior rooms, baths and showers in zones type 1 and 2 as well as outside as per DIN VDE 0100 part 701 / IEC 60364-7-701 and must only be powered with SELV 12 V DC.

transformer

The voltage supply from the 12 V DC SELV must only be fed via the included transformer type 19769610. The transformer must be installed outside the zones 0, 1 and 2 in a socket in the wall – safe from outside contact.
The mains voltage of 100 – 240 V AC 50 – 60 Hz must be supplied via a shutoff device (switch) as well as a ground fault protector (RCD / FI) with a measured differential current of ≤ 30 mA.
The transformer type 19769610 is only suited for the voltage supply of the light type 40871000.

A different or excessive use is considered non-intended.
The user/operator bears the sole risk. The intended use includes the adherence to the operating instructions and the observance of the inspection and maintenance guidelines.

The manufacturer/seller of this light does not assume any responsibility for injuries or damage that may be caused by improper installation or non-intended use.

Electrical installation

Electrician
The installation and test work must be performed by an authorized electrician under consideration of DIN VDE
0100 part 701 / IEC 60364-7-701.
Electrical connection
Voltage supply: 100 – 240 V / N /PE / 50 – 60 Hz
Residual current protection system
The circuit must be protected via a ground fault protector (RCD / FI) with a measured differential current of ≤ 30 mA.
The proper function of this fusing/protection must be checked at regular intervals.

Installation Instructions

Any work may only be carried out in a de-energized state. Here, the voltage supply must be safely separated via the main switch or mains plugs.

Consistency of installation surface

Please also make sure that the installation surface is even. If there are deep ridges or offset tiles, it is necessary to even out this unevenness using silicone. First, the basic set order no. 40876180 must be installed.
Pull the connecting line to light/transformer into the empty conduit by means of a cable retractor (EN 20).
Only standardized materials may be used for the installation.
All components must remain accessible.
The ambient temperature must not exceed 40 ºC.

Standards and guidelines

If installed and used as intended, the light and the respective transformer fulfill the standards EN 60598- 2-2 / EN 60335-2-105 as well as the low voltage and EMC guidelines.

Technical Data

Light

Nominal voltage: 12 V DC / 50 Hz SELV
Power: 3 W
Protection class: IP X5
Serial number: 40871000 (see typeplate)
Dimensions: see page 60
weight: 739 g

transformer

Input (IN): 100 – 240V / 50 – 60Hz / 70 – 170 mA
Output (OUT): 12 V DC / 500 mA
Protection class: IP 20
Serial number: 19769610 (see typeplate)
Dimensions: see page 60
weight: 81 g
The transformer must not be installed in protection zones 0, 1 or 2.
The transformer must be installed inside the wall in a socket. This socket inside the wall is connected to the light via an empty conduit EN 20.
The specifications are identical to the data on the type plate for the light and the transformer.

Connecting cable between light/transform

Cable length: 7 m
Wire cross section: approx. 0,25 mm²
– Wire color: black (GND)
+ Wire color: red (12 V DC)
Protection type of plug to the light: IP 68
Connection on the transformer: Clamp connection
Empty conduit for cable: EN 20
If the connecting cable is shortened, it must be fitted with 0.25 mm² wire end plugs and a contact length of 8 mm.

Cleaning / Repair

Cleaning recommendations, see enclosed brochure.

Illuminant change
Any work may only be carried out in a de-energized state. Here, the voltage supply must be safely separated via the main switch or mains plugs.
The operator can perform the illuminant change.
Illuminant (3,6 W / 0,3 A / 3200 K)
Order number: 95465000
Illuminant change see page 63
All spare parts must be purchased at the dealer’s.

TROUBLESHOOTING

Fault Cause Remedy
Light does not light up
  • No mains power

|

  • Check input/output voltage of the transformers

  • Transformer defective

|

  • Replace transformer

  • Illuminant defective

|

  • Replace illuminant

hansgrohe 40871000 AXOR STARCK Lighting Module

CUSTOMER SERVICES

Hansgrohe
Postfach 1145 · D-77761 Schiltach
Telefon +49 (0) 78 36/51-1282
Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com
Internet: www.hansgrohe.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

hansgrohe User Manuals

Related Manuals