MF360EN3 MeacoFan 360 Personal Air Circulator Instruction Manual
- June 10, 2024
- MEACO
Table of Contents
- MF360EN3 MeacoFan 360 Personal Air Circulator
- Safety Information
- Power Supply
- Product Identification
- Control Panel
- Electrical Connections & Operating Conditions
- Specifications
- Cleaning & Maintenance
- Storage
- Troubleshooting
- Warranty & Customer Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MF360EN3 MeacoFan 360 Personal Air Circulator
MeacoFan 360 Personal Air Circulator
Please read this instruction manual before using the air circulator and keep
safe for future reference.
Thank you for choosing Meaco, we really appreciate it.
Safety Information
This air circulator must not be used in rooms under the following conditions: potentially explosive atmosphere, aggressive atmospheres, featuring a high concentration of solvents or an extremely high ratio of dust.
- Keep Children Away: Do not allow children to play with or around this unit, which could result in injury. Be sure the unit is inaccessible to children when not attended. This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Keep Unit Grounded : Always operate the unit with a grounding plug and a grounded electrical outlet. A grounding plug is an essential safety feature that helps reduce the risk of shock or fire.
- Protect Power Cord from Damage : Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of the same type and amperage rating.
- Extension Cords : Extension cords must be grounded and able to deliver the appropriate voltages to the unit.
- Handle with Care : Do not drop, throw or crash the air circulator. Rough treatment can damage the components or wiring and create a hazardous condition.
- Run on Stable Surface : Always operate the unit on a stable, level surface, for example, the floor or a strong counter, so that the air circulator cannot fall and cause injury.
- Keep Out of Water : Never operate the unit in pooled or standing water, as this may create a risk of injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components become wet, thoroughly dry them before using the unit. If in doubt do not use the air circulator and consult a qualified electrician or a Meaco-approved engineer.
- Keep Air Intakes Clear : Do not clog or block the air intakes by placing the air circulator too close to curtains, walls or anything that will restrict the air inlet. This may cause the unit to overheat and result in a fire or electrical hazard.
- Keep Electrical Components Dry : Never allow water inside the air circulator’s electrical components. If these areas become wet for any reason, thoroughly dry them before using the air circulator. If in doubt, do not use the air circulator and consult a qualified electrician or a Meaco-approved engineer.
The operator must make the operating instruction available for the user and make sure that the user does understand the manual.
Power Supply
- This power supply changes mains alternating current to touch safe low voltage (DC). The power supply is only designed for indoor use and should not come into contact with water or dust. To prevent overheating the power supply should not be covered when it is in use.
- The mains socket should be easily accessible. In the event of operational error, the plug should be immediately removed from the socket. In the event that the mains cable becomes damaged, then the power supply should not be used.
- The power supply contains potentially dangerous voltages internally and the cover should not be removed. All service or maintenance work should be carried out by qualified personnel.
- If you require assistance, please contact Meaco.
General Advice
- Before putting your air circulator into operation for the first time, the instruction manual should be studied carefully.
- After receiving the air circulator, you should check the unit for any transport damage. In case of damage, you should inform the sender immediately.
- Keep the packaging for the air circulator in a safe place. In order to save space, you can simply cut through the adhesive tape using a knife and fold the cardboard box.
Product Identification
- Front guard
- Front shell
- Blade nut
- Fan blades
- Motor holder
- Fan motor
- Control panel
- Base
- USB connection point
- Handle
- Back guard
- USB cable and plug
When you first receive the fan, the fan cable and mains adapter must be connected to the base of the fan. In order to do this, see the diagram below. The cable can be inserted into the fan either way up. Do not try and force the connection.
Control Panel
Please note all the buttons are touch-sensitive and bleep when pressed.
Power
- When plugged in the fan will bleep once and display the room temperature on the display, this is standby mode. To turn the fan on press the ON/OFF button. The fan will bleep and start to operate. To turn the fan off press the ON/OFF button again, you will hear a longer bleep and the fan will slow down and stop.
Speed
- Press the speed button to adjust the airflow fan speed. There are 12 fan speeds available. As long as the fan remains plugged in the fan will remember the last fan speed used. The speed can be adjusted on the control panel.
Oscillation (OSC)
- Press the oscillation button to start and stop the sideways oscillation left and right. Press the button once to turn the oscillation on and press the button again to stop the motion, in doing so you can fix the direction of the fan.
- The up-and-down angle can be fixed manually by hand, place one hand on the base and one hand on the top of the fan, and gently move the head up or down as required.
Timer
- On Timer : When the fan is in standby mode use the timer button to set an interval, in 30-minute segments, between 1 and 6 hours after which the fan will turn ON. Once you have reached the desired number of hours on the display the number will flash four times and then set.
- Off Timer: When the fan is turned on and running, use the timer button to set an interval, in 30-minute segments, between 1 and 6 hours after which the fan will turn OFF. Once you have reached the desired number of hours on the display the number will flash four times and then set
Electrical Connections & Operating Conditions
- This air circulator was designed to operate in a 220V-240V/50Hz electrical installation. Make sure that the electric sockets are connected to the earth and that all safety precautions are taken.
- This air circulator can be operated within an ambient temperature range from +5°C to +40°C and with a non-condensing relative humidity.
Specifications
Operating conditions | +5°C / +40°C |
---|---|
Humidity operating range | Non-condensing |
Fan motor type | DC |
Maximum air flow | 360 cubic metres per hour |
*Maximum air velocity (c) | 4.8m/sec |
*Rated voltage and frequency | 220-240V / 50Hz |
Power consumption | 2.5 to 10 watts |
*Standby power consumption (PSB) | 0.2 watts |
Oscillation swing angles | 60° up and 20° down manually |
38° left and 38° right automatically
*Fan sound power level (LWA)*| 15 to 50dB(A)
Service value (SV)| 0.50 (m³/min)/W
Fan power input (P)| 10 watts
Maximum fan flow rate (F)| 5.09m³/min
Dimensions (HWD)| 298 x 213.5 x 209mm
Nett / Gross weight**| 1.5 / 2.4 Kgs
Measurement Standard for Service Value (all items*): EN 55014:2017
Cleaning & Maintenance
Always turn the fan off and unplug it from the socket before cleaning.
Use a soft dry cloth to clean the external and internal parts of the fan. Do
not allow the fan to get wet. In order to access the fan blades, follow the
steps below:
- Using a screwdriver, unscrew the small screw on the back of the fan on right-hand side. It is located towards the bottom of the fan.
- Squeeze four locks to pull away the front guard. At the front of the fan blades there is a nut – unscrew the nut to remove the fan blades.
- Clean the fan blades and the internal part of the fan using a soft dry cloth. Reverse the procedure to put the fan back together. Make sure the locking cap is tightened securely
Storage
We recommend storing the fan its plastic bag or original box to protect the
fan from dust. Alternatively, a customized bag can be purchased from
www.meaco.com.
Remember the fan can also be used in winter to help distribute warm air more
effectively within a room.
Troubleshooting
Trouble | Cause | Solution |
---|
The display shows ‘00’ or ‘99’
| There is a problem with the PCB circuit| Please contact Meaco
The fan does not oscillate| The MPCB needs resetting| Unplug the fan
from the mains for 40 minutes
Increased noise level| The fan blades are dirty| Clean the fan blades
(see page 6)
The fan blades or fan motor is loose| Tighten the locking cap (see page 6)
There is a fault with the fan motor| Please contact Meaco
The motor can be heard on the lower fan speeds| As the fan is so quiet
it is expected to hear the motor on the lower fan speeds. As the fan speed
increases, the noise of the motor will reduce| This is not a fault and is
normal
The fan does not start up| The fan is in standby mode| Press the power
button again
The fan is making a clicking noise| The fan needs lubricating| Run the
fan on the highest fan speed for 4 hours
Warranty & Customer Service
There is a two-year manufacturer’s warranty on your air circulator from the
date of purchase. Please register your purchase at https://meaco.com
/warranty-register – as a thank you, you will be entered into our monthly
free prize draw to help support the David Shephard Wildlife Foundation.
Registering also allows us to keep you update with any important developments
concerning your product.
Within the two-year manufacturer’s warranty, all manufacturing defects will be
repaired free of charge.
The following applies
- Any repairs or replacement of components during the warranty period will not result in an extension of the warranty period.
- The warranty will expire if any alterations have been made, not genuine components have been fitted or if the air circulator has been repaired by a third party.
- Components subject to normal wear and tear are not covered by the warranty.
- The warranty is only valid on presentation of the original, unaltered, and date-stamped purchased receipt.
- The warranty does not cover damage caused by actions that deviate from those as described in the user’s manual or by neglect.
- The warranty does not cover faults caused by dirt or by third-party products.
- The warranty does not cover accidental damage.
- All claims for compensation, including consequential damage, will not be entertained.
- Using a third-party switching device that turns the air circulator on or off via the mains will invalidate the warranty.
For the full list of the warranty terms and conditions please visit:
www.meaco.com/warranty-terms.
To prevent unnecessary expenses, we recommend that you always carefully read
the user’s manual first. If this does not provide a solution, please call
Meaco and we will be happy to help.
This air circulator has been imported into the UK by:
Meaco (UK) Limited Meaco House, Parklands Railton Road, Guildford GU2 9JX
Telephone: 01483 234900
Email: customerservice@meaco.com
Website : www.meaco.com
Please record, for future reference, your date of purchase and where you bought the air circulator from here:
- Date of purchase: …………………..…………………
Purchased from www.meaco.com (if not, then please record the supplier’s name below).
- Suppliers name: ………………………………………..
If your air circulator develops a fault at any time, please contact us and we
will always try and help you as best we can. Please keep hold of the original
box and packaging your unit arrived in.
This marking indicates that this product should not be disposed of with other
household wastes throughout the UK. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased. They can take this product for
environmentally safe recycling
References
- Meaco (U.K.) Limited
- Meaco (U.K.) Limited
- Warranty Terms
- Register Your Meaco Product Warranty Today!
Read User Manual Online (PDF format)