unitech RP902 MFi Bluetooth UHF Pocket Reader User Guide
- October 30, 2023
- unitech
Table of Contents
- Differentiate RP902/RP902 MFi
- Package
- Product View
- Install the Battery
- Specifications
- Getting Start
- Button & LED Overview
- LCD Display
- Default Settings
- LED Indication
- Power Up/ Shut Down
- Setting Page
- Reading RFID Tags
- Charging the Battery
- Disconnect
- Firmware Update
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RP902 MFi
Bluetooth UHF Pocket Reader
V1.2
Quick Start Guide
Differentiate RP902/RP902 MFi
There are five ways to differentiate between RP902 Standard Version and RP902
MFi Version:
Gift Box Outlook
RP902 MFi version will have the MFi mark on the gift box (please refer to the
picture below).
P/N on the Product Label (in the battery compartment)
RP902 Standard | RP902 MFi |
---|---|
• RP902-33E8S0G | • RP902-33EMS0G |
• RP902-43A8S0G | • RP902-43AMS0G |
• RP902-43F8S0G | • RP902-43FMS0G |
Product Label Color
RP902 Standard
RP902 MFi
Operating Mode in the Setting Page
RP902 Standard
- Supports “USB SPP, BT SPP, BT HID, Buffer & BLE HID
RP902 MFi
- Only supports “USB SPP, BT SPP & Buffer”
Bluetooth Name Format on the Host Device (During Bluetooth Pairing)
RP902 Standard
- RP902_XXXX
RP902 MFi
- RP902_i_XXXX
Package
Please make sure the following contents are in the RP902 MFi gift box. If
something is missing or damaged, please contact your Unitech representative.
The Package Contents
- RP902 MFi Terminal
- Battery (PN#1400-900066G)
- USB Type-C Cable (PN#1550-905908G)
Optional Accessories
- One-Slot Charging Cradle (PN#5000-900096G)
- Neck Lanyard (PN#3210-900019G)
- Power Supply (PN#1010-900067G)
- RFID tags/labels
Product View
1. Status LED | 7. Antenna Area |
---|---|
2. Communication LED | 8. Battery Lock |
3. 0.96” LCD | 9. Battery Cover |
4. Power/Triger Key | 10. USB Type-C Port |
5. Select Down/Power Off | 11. POGO Pin |
6. Function/Select Up Key | 12. NFC Tag |
Install the Battery
- Turn the terminal to its rear side, and push the battery lock to the right to unlock the battery.
- Grab two protrusions on both sides of the battery cover, and lift upward to remove it.
- Insert the battery into the battery compartment from the top side and press down, make sure to leave half of the battery strap outside.
- Press down the battery.
- Align two hooks at the bottom of the battery cover with the recesses on the battery compartment and insert, please make sure to completely cover the battery strap.
- Press down the battery cover, and push the battery lock to the left to secure the battery.
Note: Please ensure the battery strap is not revealed.
Specifications
Frequency | 865 – 928 MHz (US/EU/JP/TW/CN) |
---|---|
Standard | EPC global Class1 Gen2, ISO/IEC 18000-6C |
Read Range | 1M : When Power is 22dBm |
2M : When Power is 27dBm
(Depends on the type and quantity of RFID tag and environment)
Weight| 106g
Operating Time| > 12 hours with 75,000 tag readings
Charge Time| 2 hours (via RP902 charging cradle)
3.5 hours (via USB type-C cable)
Bluetooth| Bluetooth® 5.0 (SPP(iAP2))
Compatibility| RP902 with MFi Version : BT: iOS (MFi)
USB: Windows
RP902 Without MFi Version
BT: Android / Windows / iOS (BLE) USB: Windows
Operating Temp| -10°C to 50 °C
Getting Start
Turning on RP902 MFi for the first time
-
Short press the power/trigger key to power on RP902 MFi.
Note:
Power on RP902 MFi for the first time, the communication LED will show green flash first then “flashing blue light” to indicate that RP902 MFi is waiting for Bluetooth connection. -
Enable the BT function of the host device and select “RP902_i_XXXX (RP902 MFi terminal name)” to connect with RP902. After connection, the communication LED shows solid blue light.
Note: RP902 MFi supports NFC quick pairing.
Button & LED Overview
LCD Display
Left: The icon and the alphabet indicates the operation mode.
(e.g., in the picture, it indicates Bluetooth SPP mode.)
Middle: Time
Right: Battery State
Default Settings
Operating Mode | BT SPP Mode |
---|---|
Read Mode | Single Read |
Power Setting | 22 dBm |
Beep Setting | Low |
Vibrate Setting | Enable |
Auto Power-off | 2 min |
LED Indication
LED LED Status | Status LED | Communication LED |
---|---|---|
Off | Power off/ Fully charged | ―― |
Red Solid | Battery charging | Connected with USB cable |
Green Flash | RFID tag being read successfully | RP902 Mfi turned on |
Blue Flashing | ―― | Waiting for BT connection |
Blue Solid | ―― | BT connection success |
Note:
During F/W Upgrade, Status LED will show solid red light.
Power Up/ Shut Down
Power Up
- Short press the Power / Trigger Key to power up, and you wellhead short beeps (SPP mode: 1 beep/Buffer mode: 3 beeps) with green flash appears on the communication LED, then theLCD screen will appear.
Shut Down
- Long press the Select Down / Power Off button for about 3 seconds to shut down the terminal.
Power On / Off
Power On| Short press Power / Trigger Key
Power Off| Long press Select Down / Power Off Key about 3 secs
Setting Page
Enter the Setting Page| Short press Function / Select Up Key
Enter| Short press Power / Trigger Key
Up| Short press Function / Select Up Key
Down| Short press Select Down / Power Off Key
Read Mode
Single read: Short press Power / Trigger Key
Multiple read: Keep pressing Power / Trigger Key
Counter read: Press and hold the Power / Trigger key
Rapid read: Short press Power / Trigger Key
Note : Please select the multiple reading mode to enable Continuous
Reading.
Return to Scan Page
Long press Function / Select Up Key about 3 seconds
Setting Page
Operating Mode | USB SPP mode |
---|
BT SPP mode
Buffer mode
Note :
• The “” indicates the default setting.
• The data will be temporarily saved in the reader under Buffer Mode
Read Mode| Single read
Multiple read
Counter read
Rapid read
Power Setting| 11-27 dBm (22 dBm)
Beep Setting| High
Medium
Low
Mute
Vibrate Setting| Enable
Disable
Auto Power-off| Disable
1-3/5/10 min (*2 min)
Factory Default| Enable/Disable
Note: For more details, please refer to RP902 MFi
User’s Manual which can be download through
https://www.ute.com/en/products/detail/RP902MFi
Data | Format | *Hex |
---|
ACII
Tag-Info| EPC
USER (0~5)
TID
Tag-Unique| by EPC
by Tag-Info
Terminator
| None/Null
CR/LF
Tab
HID Char-Delay| 1ms
5ms
*10ms
20ms
50ms
100ms
Information| FW Version
Serial Number
MAC Address
SKU ID
Temperature
Note: SKU ID: 1 = EU, 2 = US, 3 = JP
Operating Mode
Operating Mode
Icon| Operating Mode
| USB SPP
| BT SPP
| Buffer
Note:
Once you select a different operating mode, the terminal will automatically
restart.
To enable USB SPP and BT SPP mode, please refer to Tag Access APK through the
link: https://www.ute.com/en/products/detail/RP902
(Downlaod Section) or scan the barcode on the left.
Reading RFID Tags
It is recommended to read RFID tags by aiming the antenna area of RP902 MFi at the RFID tag horizontally (as shown in the picture below.)
Reading distance may be impacted by the type of tag and environmental
conditions.
Reading range is 1m when power is 22dBm, and the maximum reading range is 2m
when power is 27 dBm.
Charging the Battery
- Plug the one end of the USB Type-C cable into the port on the reader and another end into a USB port on the host PC or power adapter.
- Please fully charge the reader (or until the Status LED turns off) before use. Required Time for full charge: One-Slot Charging Cradle: 2 hours USB Type-C Cable: 3.5 hours
Read Mode
Single read: The terminal only reads one tag upon each press.
Please release the Power / Trigger Key and press again to read another tag.
The LCD screen will show the EPC code of the RFID tag being read (shown as
picture below).
Multiple read: The terminal can read multiple tags that are under RF
coverage upon each press.
Keep pressing the Power / Trigger Key to read the tags that have not been
read. The tags that had been read will not be read again, unless you release
the button and press again.
When there is only one tag: Shows the EPC Code of the tag being read.
Multiple tags being read: Shows the amount of tags being read.
*Note: Please note that RP902 MFi does not support continuous reading by
single press the trigger key for more than 15 seconds. Users need to release
the trigger key and press again to start a new round of reading.
Disconnect
Long press (about 3 – 5 secs.) the two buttons at the bottom of RP902 MFi at the same time to release the BT connection between the host device and RP902 MFi.
Firmware Update
Note: For more details, please refer to RP902 MFi F/W
Update Instruction which can be download through
https://www.ute.com/en/products/detail/RP902MFi (FAQ Section), or by
scanning the barcode below.
Remove the Battery
- Turn the terminal to its rear side, and push the battery lock to the right to unlock the battery.
- Grab two protrusions on both sides of battery cover, and lift upward to remove it.
- Pull the battery strap upward to remove.
WARNING!
There is a risk of fire and burns if the battery is handled improperly.
DO NOT disassemble, crush, puncture, short external contacts, or dispose the
battery pack in fire or water.
DO NOT attempt to open or service the battery.
Dispose used batteries according to local recycling guidelines in your area.
CAUTION!
To ensure the unit working properly, please keep all connectors away from the
contaminants such as dust, grease, mud, and water.
Negligence may cause the unit to lose communication, short circuit, or
overheated. If the connector is damaged, please ensure the connector is fully
repaired before using the unit to avoid short circuiting.
http://www.ute.com/
Copyright 2023 Unitech Electronics Co., Ltd. All rights reserved.
Unitech is a registered trademark of Unitech Electronics Co., Ltd.
References
- Unitech Global | Your Brilliant AIDC Solution Provider
- RP902 Bluetooth UHF RFID Pocket Reader │ Unitech
- RP902 MFi Bluetooth UHF RFID Pocket Reader │ Unitech
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>