ELSYS Firmware Upgrade Tool User Guide

October 30, 2023
ELSYS

ELSYS Firmware Upgrade Tool User Guide
Firmware Upgrade Tool

REQUEST FIRMWARE
Request firmware by checking our website. The firmware is supplied as .bin- files

PREPARATION

  1. Connect the Upgrade Tool to the computer with a micro-B USB cable (one is provided with the Upgrade Tool). It appears as a USB drive. It should already have two files, one readme, and one JavaScript file. Do not remove these files; they should always be on the Upgrade Tool. If the JavaScript file is accidentally deleted, it can be downloaded here.
  2. Add the .bin file to the Upgrade Tool by dragging and dropping it into the file explorer on your computer.
  3. Disconnect the programming stick from the computer before programming.

NOTE: You can only use the Upgrade Tool with one firmware at a time, so the Upgrade Tool should only contain one .bin-file. The preparation steps 1-3 must be repeated for every unique firmware/device type.

PROGRAMMING

  1. If the device to upgrade does not have a battery inserted, Connect the Upgrade Tool to a 5V USB port (computer/charger/power bank).
  2. Hold the Upgrade Tool to the programming port on the device (see pictures below). The LED on Upgrade Tool may stop lighting due to the supercapacitor charging; keep holding the Upgrade Tool to the programming port if this happens.
  3. Upgrade Tool starts programming once connected.
  4. If the programming is successful, the sensor will perform a boot up, and the sensor LED will flash BLUE, RED, GREEN, and YELLOW.

NOTE: If you have problems with the programming procedure when the Upgrade Tool is connected to a computer, you can try connecting it to a different USB port or power source. The computer might not provide sufficient current to the Upgrade Tool or may cause problems by trying to communicate with the EKP during programming

  • ERS programming port
    ERS programming port

  • EMS programming port
    EMS programming port

  • ELT programming port
    ELT programming port

EKP LED BEHAVIOR

Successful programming sequence:

LED Flashing Green: Waiting for the device
LED Flashing Yellow & Red: Programming
LED Green Red: Finishing
LED Flashing Green: Finished

Errors

LED flashing orange: FAT error
LED flashing red: Internal error
LED fixed red: Error or startup

Elektroniksystem i Umeå AB
Tvistevägen 48
90736 Umeå, Sweden
[email protected]
+4690100500 www.elsys.se
Document may change without further notice. Misprints and errors reseved.