APEX WAVES CVS-1450 Compact Vision System User Guide
- October 30, 2023
- APEX WAVES
Table of Contents
Getting Started with the NI CVS-1450 Series
Compact Vision System
Bridging the gap between the manufacturer and your legacy test system.
CVS-1450 Compact Vision System
COMPREHENSIVE SERVICES
We offer competitive repair and calibration services, as well as easily
accessible documentation and free downloadable resources.
SELL YOUR SURPLUS
We buy new, used, decommissioned, and surplus parts from every NI series. We
work out the best solution to suit your individual needs.
Sell For Cash
Get Credit
Receive a Trade-In Deal
OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP
We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.
Request a Quote CVS – 1454
NI CVS-1450 Series compact vision system is an are easy-to-use, distributed,
real-time imaging system that acquires, processes, and displays images from
IEEE 1394 cameras conforming to the IIDC 1394-based Digital Camera
Specification, Version 1.30. This document provides instructions for setting
up the NI CVS-1450 Series hardware. This document includes instructions for
installing software, configuring an IP address, and acquiring an initial image
using LabVIEW and the NI Vision Development Module.
For information on setting up and configuring the NI CVS-1450 device and
developing your applications using NI Vision Builder for Automated Inspection
(Vision Builder AI), refer to the NI Vision Builder for Automated Inspection
Tutorial.
What You Need to Get Started
You need the following items to set up and use the NI CVS-1450 device:
-
NI CVS-1450 Series compact vision system
-
Development computer running Windows Vista/XP/2000
-
DCAM-compliant IEEE 1394 camera
-
IEEE 1394 jackscrew-to-latch cable (part number 778796-01) or any standard IEEE 1394 cable.
You can use a 4-pin to 6-pin converter cable with cameras that have their own external power supply and do not require power from the IEEE 1394 bus -
NI desktop power supply (part number 778794-01) or any 24 VDC ±10%, 50 W power supply
– Power supply cord—Connects the NI desktop power supply to an outlet. Refer to ni.com for the part number specific to your region and ordering information
– 4-position power connector—Required if you do not use the NI desktop power supply -
10 m standard CAT 5 10/100Base-T Ethernet cable (part number 189174-10)
-
NI Vision Acquisition Software 8.2.1 or later, which includes the NI-IMAQdx driver software
-
Software for developing applications:
–LabVIEW
– LabVIEW Real-Time Module
– NI Vision Development Module
Optional Equipment
National Instruments offers a variety of products for use with the NI CVS-1450
device, including the following:
- DCAM-compliant IEEE 1394 cameras
- Camera lenses
- Ring and back lights
- NI Vision I/O Terminal Block and Prototyping Accessory (part number 779166-01)
- DIN rail/panel mount kit (part number 189154-01)
- Digital I/O cable and horizontal DIN rail terminal block (part number 778790-01)
- Digital I/O cable and vertical DIN rail terminal block (part number 778791-01)
- 75 Ω SMB 111 coaxial cable (part number 763422-01)—SMB to BNC cable for connecting to triggers and light sources
Visit ni.com or call the National Instruments office nearest you for more information about these products.
Related Documentation
The following documents contain additional information that you may find
helpful:
- NI CVS-1450 Series User Manual—Contains information about programming options, hardware functionality, and signal connections.
- NI Vision Acquisition Software Release Notes—Outlines new functionality, system requirements, installation procedures, and descriptions of the documentation included with the NI-IMAQdx driver software.
- Measurement & Automation Explorer Help for NI-IMAQdx—Describes how to configure the NI-IMAQdx driver software, NI interface devices, and cameras using Measurement & Automation Explorer (MAX).
- NI-IMAQdx Help—Contains fundamental programming concepts for the NI-IMAQdx driver software and terminology for using NI image acquisition devices.
Safety Information
Caution The following paragraphs contain important safety information you must
follow when installing and operating the device.
Do not operate the device in a manner not specified in the documentation.
Misuse of the device may result in a hazard and may compromise the safety
protection built into the device. If the device is damaged, turn it off and do
not use it until service-trained personnel can check its safety. If
necessary, return the device to National Instruments for repair.
Keep away from live circuits. Do not remove equipment covers or shields unless
you are trained to do so. If signal wires are connected to the device,
hazardous voltages can exist even when the equipment is turned off. To avoid a
shock hazard, do not perform procedures involving cover or shield removal
unless you are qualified to do so. Disconnect all field power prior to
removing covers or shields.
If the device is rated for use with hazardous voltages (>30 Vrms, 42.4 Vpk, or
60 Vdc), it may require a safety earth-ground connection wire. Refer to the
device specifications for maximum voltage ratings.
Because of the danger of introducing additional hazards, do not install
unauthorized parts or modify the device. Use the device only with the chassis,
modules, accessories, and cables specified in the installation instructions.
All covers and filler panels must be installed while operating the device.
Do not operate the device in an explosive atmosphere or where flammable gases
or fumes may be present. Operate the device only at or below the pollution
degree stated in the specifications. Pollution consists of any foreign matter—
solid, liquid, or gas—that may reduce dielectric strength or surface
resistivity. The following is a description of pollution degrees.
- Pollution Degree 1—No pollution or only dry, nonconductive pollution occurs. The pollution has no effect.
- Pollution Degree 2—Normally only nonconductive pollution occurs. Occasionally, nonconductive pollution becomes conductive because of condensation.
- Pollution Degree 3—Conductive pollution or dry, nonconductive pollution occurs. Nonconductive pollution becomes conductive because of condensation.
Clean the device and accessories by brushing off light dust with a soft,
nonmetallic brush. Remove other contaminants with a stiff, nonmetallic brush.
The unit must be completely dry and free from contaminants before returning it
to service.
You must insulate signal connections for the maximum voltage for which the
device is rated. Do not exceed the maximum ratings for the device. Remove
power from signal lines before connection to or disconnection from the device.
Caution National Instruments measurement products may be classified as
either Measurement Category I or II. Operate products at or below the
Measurement Category level specified in the hardware specifications.
Measurement Category¹: Measurement circuits are subjected to working voltages²
and transient stresses (overvoltage) from the circuit to which they are
connected during measurement or test.
Measurement Category establishes standardized impulse withstand voltage levels
that commonly occur in electrical distribution systems. The following is a
description of Measurement (Installation 3)
Categories:
- Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS4 voltage. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
- Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet (e.g., 115 V for U.S. or 230 V for Europe). Examples of Measurement Category II are measurements performed on household appliances, portable tools, and similar products.
- Measurement Category III is for measurements performed in the building installation at the distribution level. This category refers to measurements on hard-wired equipment such as equipment in fixed installations, distribution boards, and circuit breakers. Other examples are wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and stationary motors with permanent connections to fixed installations.
- Measurement Category IV is for measurements performed at the primary electrical supply installation (<1,000 V). Examples include electricity meters and measurements on primary overcurrent protection devices and on ripple control units.
1. Measurement Categories as defined in electrical safety standard IEC 61010-1.
2. Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.
3. Measurement Category is also referred to as Installation Category.
4. MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for the purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring purposes.
Hardware Installation
Figure 1 illustrates the sequence for setting up the NI CVS-1450 device.
The following instructions are for general installation. Refer to the
documentation provided by your computer manufacturer for specific instructions
and warnings. Refer to the Specifications section for typical power
requirements for the NI CVS-1450 device.
Connecting a Camera and Monitor to the NI CVS-1450 Device
Before connecting a camera and monitor to the NI CVS-1450 device, make sure
that all NI CVS-1450 device DIP switches are in the OFF position.
To connect an IEEE 1394 camera and a monitor to the NI CVS-1450 device, refer
to Figure 2 while completing the following steps:
-
Connect the VGA cable from the monitor to the VGA port on the NI CVS-1450 device.
-
Plug the IEEE 1394 cable into one of the IEEE 1394a ports on the NI CVS-1450 device. Plug the other end of the cable into the IEEE 1394 port on the camera.
If your camera requires an external power supply, connect it to the camera, and verify that the camera is powered on.
Note To maintain signal integrity, the IEEE 1394 cable length must be no longer than 4.5 m. -
Plug in and power on the monitor.
Wiring Power to the NI CVS-1450 Device
This section describes how to connect the NI desktop power supply. For
instructions on how to connect a separate main supply, refer to the Connecting
to a Separate Main Supply section.
Caution Do not connect the NI CVS-1450 device main power to a source
other than 24 VDC ±10%.
Do not connect the NI CVS-1450 device isolated power to a source less than 5
VDC or greater than 30 VDC. Doing so could damage the NI CVS-1450 device.
To connect power to the NI CVS-1450 device, refer to Figure 3 while completing
the following steps:
- Plug the 4-position connector from the power supply into the power receptacle on the NI CVS-1450 device.
- Plug the power cord into the power supply.
- Plug the power cord into an outlet.
The NI CVS-1450 device ships with a factory-installed startup program that, when the NI CVS-1450 device is connected to a camera and powered on, acquires images and displays them on the monitor.
If the images from the camera display on the monitor, continue to the Connecting the NI CVS-1450 Device to a Network section. If the images from the camera are not displayed on the monitor, refer to the NI CVS-1450 Series User Manual for troubleshooting information.
Connecting to a Separate Main Supply
If you use a power supply other than the NI desktop power supply, follow the
instructions in this section to connect power to the NI CVS-1450 device.
Note If you are not using the NI desktop power supply, use 0.75 mm², 18
AWG ferrules according to manufacturer specifications to terminate the wires
leading to the 4-position power connector, as shown in Figure 4. Ferrules are
available from Phoenix Contact (part number 3200519).
Caution Do not connect the NI CVS-1450 device main power to a source
other than 24 VDC ±10%.
Do not connect the NI CVS-1450 device isolated power to a source less than 5
VDC or greater than 30 VDC. Doing so could damage the NI CVS-1450 device.
The NI CVS-1450 device ships with a 4-position power connector that plugs directly into the power input connector on the NI CVS-1450 device. To wire power to the 4-position connector, complete the following steps:
- Wire the voltage output of the 24 VDC ±10% power supply to the main voltage input, labeled V, on the 4-position connector.
- Wire the common-mode signal (ground) output of the power supply to the common-mode signal input, labeled C, on the 4-position connector.
If you are using a separate power supply for the NI CVS-1450 device isolated
outputs, connect the voltage output on the power supply to the isolated power
(Viso) on the 4-position connector. Connect the common-mode signal on the
power supply to the isolated common-mode signal (Ciso) on the connector.
Note If you do not require a separate power supply for the NI CVS-1450
device isolated outputs, you can daisy-chain the V to the Viso and the C to
the Ciso on the connector.
For information about grounding the NI CVS-1450 device chassis to earth
ground, refer to the NI CVS-1450 Series User Manual.
Connecting the NI CVS-1450 Device to a Network
Use a standard CAT 5 or CAT 6 Ethernet cable to connect the NI CVS-1450 device
to a network.
If the development computer is already configured on a network, you must
configure the NI CVS-1450 device on the same network. If the development
computer is not connected to a network, you can connect the development
computer and the NI CVS-1450 device directly using a CAT 5 or CAT 6 Ethernet
crossover cable.
Caution To prevent data loss and to maintain the integrity of your
Ethernet installation, do not use a cable longer than 100 m. If you are using
a 100 Mbps Ethernet, National Instruments recommends using a CAT 5 or CAT 6
shielded twisted-pair Ethernet cable.
Subnet Considerations
To configure the NI CVS-1450 device, it must reside on the same subnet as the
development computer.
Once the NI CVS-1450 device is configured, other subnets can access and use
it.
To use the NI CVS-1450 device on a subnet other than the one on which the
development computer resides, first connect and configure the NI CVS-1450
device on the same subnet as the development computer. Next, physically move
the NI CVS-1450 device to the other subnet and reassign an IP address.
Contact your network administrator for assistance in setting up the
development computer and NI CVS-1450 device on the same subnet.
Connecting the NI CVS-1450 Device to the Development Computer
The development computer communicates with the NI CVS-1450 device over an
Ethernet connection.
Use a standard Ethernet cable to connect from the network port to the NI
CVS-1450 device.
Note If you are not connecting through a network, use an Ethernet crossover
cable to connect the NI CVS-1450 device directly to the development computer.
To connect the NI CVS-1450 device to the development computer, refer to Figure
5 while completing the following steps:
- Verify that the development computer is connected to the network and is powered on.
- Using a standard Ethernet cable, connect from the network port to the Ethernet port on the NI CVS-1450 device.
- Using a standard Ethernet cable, connect from the network port to the Ethernet port on the development computer.
1 Standard Ethernet Cable Connecting from the NI CVS-1450 Device to an Ethernet Hub
2 Standard Ethernet Cable Connecting from an Ethernet Hub to the Development Computer
3 Ethernet Hub or Other Network Port
Figure 5. Ethernet Connection
Software Installation
This section contains information about installing LabVIEW, the LabVIEW Real- Time Module, the NI Vision Development Module, and NI Vision Acquisition Software on the development computer. It also contains information on obtaining an IP address, installing software on the NI CVS-1450 device, and configuring the NI CVS-1450 device to acquire an image using the LabVIEW Real- Time Module.
Installation
Complete the following steps to install LabVIEW, the LabVIEW Real-Time Module,
the NI Vision Development Module, and NI Vision Acquisition Software onto the
development computer.
Note You must install LabVIEW, the LabVIEW Real-Time Module, and the NI
Vision Development Module software before installing NI Vision Acquisition
Software.
- Insert the LabVIEW CD into the CD-ROM drive.
- When the installation screen appears, click Install LabVIEW, and follow the setup instructions.
- Insert the LabVIEW Real-Time Module CD into the CD-ROM drive.
- When the installation screen appears, click Install LabVIEW Real-Time Module, and follow the setup instructions.
- Insert the NI Vision Development Module CD into the CD-ROM drive.
- When the installations screen appears, click Install NI Vision Development Module, and follow the setup instructions.
- Insert the NI Vision Acquisition Software disk 1 CD into the CD-ROM drive.
- When the installation screen appears, click Install NI Vision Acquisition Software, and follow the setup instructions.
- When prompted, restart the development computer.
Configuring the IP Address Using the Measurement & Automation Explorer
(MAX)
To configure an IP address for the NI CVS-1450 device using MAX, complete the
following steps:
-
Launch MAX by double-clicking the MAX icon on the desktop, or select Start»All Programs “National Instruments “Measurement & Automation.
-
Expand the Remote Systems branch of the configuration tree, and click 192.168.10.12 to display the Network Settings tab. 192.168.10.12 is the IP address assigned to all unconfigured NI CVS-1450 devices.
To uniquely identify unconfigured NI CVS-1450 devices, connect and configure one NI CVS-1450 device at a time. -
In the Network Settings tab, enter a name for the device in the Name field and a description of the device in the Comment field.
Device names are limited to 15 characters with no spaces or special characters except hyphens.
The first and last characters must be alphanumeric. -
If the network is configured to issue IP addresses using DHCP, select Obtain IP address from DHCP server. Otherwise, configure the IP address manually by selecting Edit the IP settings, Suggest Values, and OK.
-
Click Apply.
-
When prompted, restart the NI CVS-1450 device. The initialization process may take several minutes.
Downloading Software to the NI CVS-1450 Device
To download software to the NI CVS-1450 device using MAX, complete the
following steps:
-
In the MAX configuration window, click the Software tab.
-
Click Add/Remove Software on the MAX toolbar.
When you update software on a LabVIEW Real-Time target, such as the NI CVS-1450 device, while the Windows Firewall is enabled on the host computer, a dialog box may appear giving you the option to allow MAX to communicate over a network. Select Unblock this program to allow MAX to communicate with your LabVIEW RT target. You must have Administrator privileges to modify this setting. For more information, visit ni.com/info and enter winxpsp2. -
Select NI-IMAQdx RT. For initial installation, make sure all checkboxes are selected.
Note The NI-IMAQ for IEEE 1394 RT 2.0 driver software is available for legacy applications. -
Review your selection in the Summary window. Use the Back button to modify your software settings if needed.
-
Click Next.
-
Once the software is installed, the NI CVS-1450 device will automatically restart. Click Finish when this process is completed.
Acquiring an Image
This section contains information on acquiring images using the LabVIEW Real- Time Module and MAX.
Acquiring an Image Using the LabVIEW Real-Time Module
Complete the following steps to acquire an image using the LabVIEW Real-Time
Module.
- Launch LabVIEW, and select Real-Time Project.
- Select Custom project for the Project type, enter a Project name, select the Project folder where you want to store the project and click Next.
- Select Import Existing VIs to host and target, and click Add VIs in the VIs imported to run on target section.
- Navigate to
\examples\IMAQ\IMAQdx examples.llb, and click Add VIs. is the location to which LabVIEW is installed. - Click Grab.vi, and click Add VIs.
- Click Next.
- Click Browse targets to add a target or device to the project.
- Select the Existing target or device option from Targets and Devices, expand the Compact Vision System branch, select your device, and click OK.
- Click Next.
- Verify that the NI CVS-1450 device appears correctly in the LabVIEW Real-Time Project, and click Finish.
- After your project has launched, specify which camera your NI CVS-1450 device will use by selecting a camera from the Camera Name control.
- Click the Run button on the VI front panel to begin acquiring images.
Acquiring an Image Using MAX
Complete the following steps to acquire an image using the MAX.
- Launch MAX.
- In the MAX configuration tree, expand the Remote Systems folder.
- Expand the device folder of your NI CVS-1450 device.
- Expand Devices and Interfaces.
- Expand NI-IMAQdx Devices.
- Select a camera.
- Click the Snap button to acquire a single image, or click the Grab button to acquire continuous images.
Now that you are acquiring images, you can use the NI Vision Development Module and the installed NI CVS-1450 device drivers to process images and control inputs and outputs.
Specifications
The following specifications apply to the NI CVS-1450 device. These specifications are typical at 25 °C, unless otherwise stated.
Power Requirements
Main supply voltage………………………………………..24 VDC ±10%
Power (excluding cameras)……………………….12 W, typical 22 W, maximum
IEEE 1394 bus power ………………………………18 W, maximum (shared by all three ports)
Isolated supply¹………………………………………………5 to 30 VDC
Memory
SDRAM ………………………………………………………..128 MB
Nonvolatile storage
NI CVS-1454 ………………………………………….64 MB
NI CVS-1455 ………………………………………….128 MB
NI CVS-1456 ………………………………………….256 MB
Processor
NI CVS-1454 …………………………………………………Intel Celeron 400 MHz processor
NI CVS-1455 …………………………………………………Intel Celeron 650 MHz processor
NI CVS-1456 …………………………………………………Intel Celeron 733 MHz processor
Network
Network interface……………………………………………10BaseT and 100BaseTX Ethernet
Compatibility …………………………………………………IEEE 802.3
Maximum cabling distance………………………………100 m/segment
TTL Inputs and Outputs
Digital logic levels
Level
| Minimum|
Maximum
---|---|---
Input low voltage (Vm)| () V| 0.5 V
Input high voltage (VIII)| 2.2 V| 5 V
Output low voltage (Voi), at 5 mA|
—
| 0.4 V
Output high voltage (V0H), at 5 mA| 2.4 V|
—
TTL Inputs
Number of channels ………………………………………..2
Maximum pulse rate ……………………………………….2 MHz
Minimum pulse detected………………………………….500 ns
Power-on state………………………………………………..Input (high-impedance)
61.9 kΩ pull-up to 5 V
TTL Outputs
Number of channels ………………………………………..10
Output voltage range……………………………………….0 to 5 V
Maximum pulse rate ……………………………………….2 MHz
Optically Isolated Inputs and Outputs
Isolated (Current Sinking) Inputs
Number of channels ………………………………………..13
Input voltage range …………………………………………0 to 30 V
Input ON voltage……………………………………..3.5 to 30 V
Input OFF voltage ……………………………………0 to 2 V
Turn-on current ………………………………………………7.1 mA, typical
14 mA, maximum
Maximum pulse rate ……………………………………….100 kHz
Minimum pulse detected………………………………….10 µs
Reverse polarity protection ………………………………Yes, –30 V
Isolated (Current Sourcing) Outputs
Number of channels ………………………………………..4
On-state voltage range …………………………………….5 to 30 V, maximum
Maximum on-state voltage
drop from Viso …………………………………………1.2 V at 100 mA
Output current
5 Viso ……………………………………………………..50 mA, maximum
24 Viso ……………………………………………………100 mA, maximum
30 Viso ……………………………………………………100 mA, maximum
Maximum pulse rate ……………………………………….10 kHz (maximum load resistance 100 kΩ)
Minimum pulse generated ……………………………….100 µs
Reverse polarity protection ………………………………Yes
IEEE 1394
Number of ports ……………………………………………..3
Camera interface …………………………………………….IEEE 1394a
Speed…………………………………………………………….100, 200, or 400 Mbps
Available bus power………………………………………..Refer to the Power Requirements section
Physical Characteristics
Dimensions ……………………………………………………10.2 cm × 12.7 cm × 6.4 cm
(4 in. × 5 in. × 2.5 in.)
Weight …………………………………………………………..1 kg (2.2 lb)
Refer to Appendix B, Mounting Information, of the NI CVS-1450 Series User
Manual for dimensional drawings of the NI CVS-1450 device.
Environmental
The NI CVS-1450 device is intended for indoor use only.
Operating temperature
Vertical mounting position………………………..0 to 55 °C
All other positions……………………………………0 to 45 °C
Storage temperature ………………………………………..–20 to 85 °C
Humidity ……………………………………………………….10 to 90% RH, noncondensing
Pollution Degree …………………………………………….2
Operating shock (IEC 68-2-27) ………………………..50 g, 6 ms half sine, 3 shocks per
side;
30 g 11 ms half sine, 3 shocks per side
Operating vibration
Random (IEC 60068-2-34) ……………………….10 to 500 Hz, 5 Grms
Swept Sine (IEC 60068-2-6)……………………..10 to 500 Hz, 5 g
Approved at altitudes up to 2,000 m.
Safety
The NI CVS-1450 device meets the requirements of the following standards for
safety and electrical equipment for measurement, control, and laboratory use:
- EN 61010-1, IEC 61010-1
- UL 61010-1
- CAN/CSA-C22.2 No. 61010-1
Note For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link the Certification column.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards
of EMC for electrical equipment for measurement, control, and laboratory use:
- EN 61326 EMC requirements; Minimum Immunity
- EN 55011 Emissions; Group 1, Class A
- CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note For EMC compliance, operate this device to product documentation.
CE Compliance
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
- 73/23/EEC; Low-Voltage Directive (safety)
- 89/336/EEC; Electromagnetic Compatibility Directive (EMC)
Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.
Environmental Management
National Instruments is committed to designing and manufacturing products in
an environmentally responsible manner. NI recognizes that eliminating certain
hazardous substances from our products is beneficial not only to the
environment but also to NI customers.
For additional environmental information, refer to the NI and the Environment
Web page at ni.com/environment. This page
contains the environmental regulations and directives with which NI complies,
as well as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of their life cycle, all products must be sent to a
WEEE recycling center.
For more information about WEEE recycling centers and National Instruments
WEEE initiatives, visit
ni.com/environment/weee.htm.
(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)
Where to Go for Support
The National Instruments Web site is your complete resource for technical
support. At ni.com/support you have access to
everything from troubleshooting and application development self-help
resources to email and phone assistance from NI Application Engineers.
A Declaration of Conformity (DoC) is our claim of compliance with the Council
of the European Communities using the manufacturer’s declaration of
conformity. This system affords the user protection for electronic
compatibility (EMC) and product safety. You can obtain the DoC for your
product by visiting ni.com/certification. If your product supports
calibration, you can obtain the calibration certificate for your product at
ni.com/calibration.
National Instruments corporate headquarters is located at 11500 North Mopac
Expressway, Austin, Texas, 78759-3504.
National Instruments also has offices located around the world to help address
your support needs. For telephone support in the United States, create your
service request at ni.com/support and follow the
calling instructions or dial 512 795 8248. For telephone support outside the
United States, contact your local branch office: Australia 1800 300 800,
Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599,
Canada 800 433 3488, China 86 21 5050 9800,
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725
72511,
France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972
3 6393737,
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961
(0) 1 33 28 28,
Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 3390150,
Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886,
Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085,
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377
2222,
Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635
523545
National Instruments, NI, ni.com, and LabVIEW are trademarks
of National Instruments Corporation.
Refer to the Terms of Use section on ni.com/legal for
more information about National Instruments trademarks.
Other product and company names mentioned herein are trademarks or trade names
of their respective companies.
For patents covering National Instruments products, refer to the appropriate
location: Help “Patents in your software, the
patents.txt file on your CD, or
ni.com/patents.
© 2007 National Instruments Corporation. All rights reserved.
Documents / Resources
| APEX
WAVES CVS-1450 Compact Vision
System
[pdf] User Guide
CVS-1450 Compact Vision System, CVS-1450, Compact Vision System, Vision System
---|---
References
- Engineer Ambitiously - NI
- Engineer Ambitiously - NI
- Calibration Services - NI
- Product Certifications - NI
- Managing Critical Substances - NI
- Managing Critical Substances - NI
- Product Take-Back Program and Recycling - NI
- Using Info Codes - NI
- Legal Information - NI
- National Instruments Patents - NI
- Support - NI
- CVS-1454 National Instruments Compact Vision System | Apex Waves
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>