hansgrohe Ecostat Bath Mixer Instruction Manual

October 30, 2023
hansgrohe

hansgrohe logo1

Instructions for use / assembly instructions

hansgrohe Ecostat Bath Mixer 1

Ecostat E
13125000 / 13126000

hansgrohe Ecostat Bath Mixer 2

Ecostat S
13235000 / 13236000

hansgrohe Ecostat Bath Mixer 3

Ecostat E
13145000 / 13124000

hansgrohe Ecostat Bath Mixer 4

Ecostat S
13245000 / 13144000


Safety Notes

Gloves should be worn during installation to prevent crushing and cutting injuries.
The shower system may only be used for bathing, hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/ or sensoric impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system.
The hot and cold supplies must be of equal pressures.

Installation Instructions

The fitting must be installed, flushed and tested after the valid norms!

Thermostatic mixer in conjunction with combination boilers
  • If fitting a hand shower remove the water limiter from the shower.
  • If the continuous water heater causes any problems, or you have different water pressures you must install a water limiter to the cold supply, (ordered separately, article number 97510000).
  • Thermostatic mixer Shower: When mounting the ECOSTOP limit stop washer (Art. No. 98916000) in connection with flow heaters, turn it axially through 180° before attaching it.
Technical Data

Operating pressure:                                       max. 1 MPa
Recommended operating pressure:              0,1 – 0,5MPa
Test pressure:                                                       1,6MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:                                   max. 80°C
Recommended hot water temp.:                              65°C
anti-pollution function

Symbol description

Do not use silicone containing acetic acid!

Safety Function
The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function.

Adjustment
After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.

ECOSTOP

Maintenance

  • To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
  • The mixer is equipped with non return valves. The non return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year).

Operation

Dimensions

Flow diagram
(1) Shower
(2) Bath tub

Spare parts

Test certificate

Fault Cause Remedy
Insufficient water – Supply pressure inadequate – Check water pressure (If a

pump has been installed check to see if the pump is working).
– Filters are dirty (96922000)| – Clean filter in front of the mixer and on the MTC-thermo cartridge (96922000)
– Shower filter seal dirty| – Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe, or vice versa, when mixer is closed| – Backflow preventers dirty or leaking| – Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with temperature set| – Thermostat has not been adjusted| – Adjust thermostat
– Hot water temperature too low| – Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible| – thermo cartridge calcified| – Exchange thermo cartridge
Shower or spout dripping| – Dirt or sedimentation on valve seat, shut-off unit damaged| – Clean or exchange shut-off unit
Instantaneous heater didn’t work with thermostat| – Ecostop limit stop
– washer not turned
– axially through 180| – Turn the limit stop washer
– (98916000) axially through 180°
– Flow limiter in handshower isn’t removed| – Remove flow limiter
– Filters are dirty| – Clean the filter / exchange filter
– Non return valve hasn’t moved back| – Exchange non return valves

Assembly

Assembly

Safety Function

Adjustment

ECOSTOP

Maintenance

Operation

open

hot

cold

close

open

hot

cold

close

Dimensions

Ecostat E 13125000

Ecostat E 13126000

Ecostat E 13124000

Ecostat E 13145000

hansgrohe Ecostat Bath Mixer - Dimensions 4

Ecostat S 13235000

Ecostat S 13236000

Ecostat S 13144000

Ecostat S 13245000

Flow diagram

Ecostat E
13124000 / 13145000
Ecostat S
13144000 / 13245000

Ecostat E
13125000 / 13126000
Ecostat S
13235000 / 13236000

Spare parts

Ecostat E 13145000 / 13124000

hansgrohe Ecostat Bath Mixer - Spare parts 1

Ecostat E 13125000 / 13126000

hansgrohe Ecostat Bath Mixer - Spare parts 2

Ecostat S 13245000 / 13144000

hansgrohe Ecostat Bath Mixer - Spare parts 3

Ecostat S 13235000 / 13236000

hansgrohe Ecostat Bath Mixer - Spare parts 4

Test certificate

|

PA-IX

| DVGW| SVGW| ACS| WRAS| KIWA|

ETA

---|---|---|---|---|---|---|---
13124000| | | | | | |
13125000|

PA-IX 18988/IB

| BT0641| X| X| X| X|

X

13126000| | | | | | |
13144000| | | | | | |
13145000|

PA-IX 18986/ICB

| BT0641| X| X| X| X|

X

13235000|

PA-IX 18988/IB

| BT0641| X| X| X| X|

X

13236000| | | | | | |
13245000|

PA-IX 18987/ICB

| BT0641| X| X| X| X|

X

hansgrohe Ecostat Bath Mixer - Test certificate

Hansgrohe • Postfach 1145 • D-77761 Schiltach • Telefon +49 (0) 78 36/51-1282 • Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com • Internet: www.hansgrohe.com

02/2011