hansgrohe Concealed Highflow Thermostatic Faucet Instruction Manual
- October 30, 2023
- hansgrohe
Table of Contents
Instructions for use / assembly instructions
PuraVida
15772XXX
Ecostat S
15715000
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
Children as well as adults with physical, mental and/ or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
The hot and cold supplies must be of equal pressures.
Installation Instructions
The fitting must be installed, flushed and tested after the valid norms!
Technical Data
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 – 0,5MPa
Test pressure: 1,6MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C
Rate of flow by 0,3 MPa: approx. 58 l/min
anti-pollution function
Symbol description
Do not use silicone containing acetic acid!
Safety Function
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
Adjustment
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
Maintenance
- To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
- The mixer is equipped with non return valves. The non return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). At this time, please also check the filter (A) situated on the BTC-thermoelement (96633000). After assembling the BTC-thermoelement, it is necessary to check the water temperature at the take off point as described under the headline “adjustment”. Before the adjustment, please check, if the warm water supply is activated and the maximum temperature of the warm water is available at the take off point.
Dimensions
Spare parts
XXX = Colors
000 chrome plated
400 white/chrome plated
Operation
Cleaning
see enclosed brochure.
Test certificate
Assembly
Fault | Cause | Remedy |
---|---|---|
Insufficient water | – Supply pressure inadequate | – Check water pressure (If a |
pump has been installed check to see if the pump is working).
– Regulator filter dirty| – Clean filters
– Shower filter seal dirty| – Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe, or vice versa, when
mixer is closed| – Backflow preventers dirty or leaking| – Clean backflow
preventers, exchange if necessary
Spout temperature does not correspond with temperature set| – Thermostat has
not been adjusted| – Adjust thermostat
– Hot water temperature too low| – Increase hot water temperature to 42 ºC to
65 ºC
Temperature regulation not possible| – Temperature regulator dirty or
calcified| – Clean temperature regulator, exchange if necessary
– For new installations: basic body incorrectly connected (should be: cold
right, hot left) or installed with 180º rotation| – Install function block
turned through 180º
Safety stop button not operating| – Spring defective
– Button calcified| – Clean spring and/or button, exchange if necessary
Assembly
Safety Function
Adjustment
Maintenance
Operation
Dimensions
15715000 15772XXX
Test certificate
|
P-IX
| DVGW| SVGW| NF| ACS| WRAS|
KIWA
---|---|---|---|---|---|---|---
15715000|
18019/II
| X| X| | X| X|
X
15772XXX| |
X
| | | X|
X
|
15715000
Spare parts
Hansgrohe • Postfach 1145 • D-77761 Schiltach • Telefon +49 (0) 78 36/51-1282
• Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com • Internet:
www.hansgrohe.com
04/2011
9.05300.04
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>