CONTENTS
- A. CINDER™40 Charge Controller (SCC1005)
- B. 2 Port ATP Roof Cap (CAP1001)
- C. VHB Tape
- D. ATP Receptacle Cover
- E. Battery MRBF Fuse Post
- F. 50A MRBF Block Fuse
- G. Negative Junction Post
- H. Solar Circuit Breaker
- I. 2x10ft 6 AWG Zip Wire with ring terminal on one end (WIR3001)
- J. 1x2ft 6 AWG Zip Wire with ring terminal on one end (WIR3003)
- K. 4 stainless steel machine screws (#8, 5/8”)
NOT INCLUDED
- Mounting screws for charge controller
TOOLS NEEDED
- 6AWG Wire Strippers
- 7/16” Socket, Nut Driver or Open Ended Wrench
- 9/16“ Socket, Nut Driver or Open Ended Wrench
-
2 Phillips Head Screwdriver
- Drill
- 1” Hole Saw
- Razor Blade
INSTALL SAFETY
- Inspect the installation area for safety hazards
- Be sure to remove all metal such as rings and other jewelry
- Disconnect all power sources and ensure solar panels are com pletely covered by a box or blanket until installation is done
WIRING DIAGRAM
INSTALL INSTRUCTIONS
- Arrange the layout of your panel(s) and wire, ensuring that:
- Roof cap is no more than 10’ from charge controller.
- Panel wires can reach roof cap.
- Charge controller is no more than 9’ from battery.
- Panels are not shaded by vents, A/C units, or other obstructions.
- Connect 10” Solar wire to the roof cap.
- Strip the ends of both positive and negative wires 1/2 inch.
- Screw the red (+) wire into corresponding positive terminal, black (-) wire into corresponding negative terminal.
- Mount cap and route 10’ cable(s) from roof to charge controller location.
*Do not make connection at this time. - Proceed to route the 10’ cable from the charge controller to the battery.
*Do not make connection at this time. - Connect the negative battery wire to the charge controller, then connect the battery positive wire through the provided solar circuit breaker as shown.
- Proceed to route the 10’ cable from the charge controller to the battery.
- Connect the positive and negative battery wires to the battery as shown below and verify the charge controller turns on.
- Connect the positive and negative solar wires to the charge controller.
- Mount your charge controller.
- Set your battery profile using the app.
- Plug SAE leads into the roof cap and uncover the panels.
- Verify system is now charging batteries.