C PROX PN20 Access Control Proximity Reader
Product Information
Access Control Proximity Reader PN20
C Prox Ltd (inc Quantek) brings to you the Access Control Proximity Reader PN20, a compact, waterproof standalone programmable access control proximity reader for up to 2000 users.The product comes with an infrared remote control, admin add card, admin delete card, user manual, self-tapping screws, wall plugs, screwdriver, star diode and IN4004 (for relay circuitprotection).
Packing List
Name | Quantity | Remarks |
---|---|---|
Proximity reader | 1 | |
Infrared remote | 1 | |
Admin add card | 1 | |
Admin delete card | 1 | |
User manual | 1 | |
Self-tapping screws | 2 | |
Wall plugs | 2 | |
Screw driver | 1 | |
Star diode | 1 | |
IN4004 (for relay circuit protection) | 1 |
Product Description
The PN20 uses Atmel microprocessor ensuring maximum performancein any environment, and the low power circuit prolongs its service life. Users can be added and deleted via admin cards making it very simple to operate. The infrared remote control allows ettings to be quickly changed, including altering the relay time.
Product Features
- Compact and waterproof standalone access control proximity reader
- Can store up to 2000 users
- Uses Atmel microprocessor ensuring maximum performance in any environment
- Low power circuit prolongs its service life
- Users can be added and deleted via admin cards
- Infrared remote control allows settings to be quickly changed,including altering the relay time
Product Specifications
- Operating voltage: 9-24Vdc
- User capacity: 2000
- Static consumption: N/A
- Operating consumption: N/A
- Card reading distance: N/A
- Frequency: N/A
- Operating temperature: N/A
- Operating humidity: N/A
- Lock output load: N/A
- Waterproof: Yes
- Dimensions: N/A
Product Usage Instructions
- Read the user manual carefully before installing the unit.
- Ensure that all the contents of the packing list are present. If any are missing, notify the supplier immediately.
- Connect the proximity reader to a power source of 9-24Vdc.
- Add or delete users using the admin cards provided.
- Use the infrared remote control to quickly change settings, including altering the relay time.
- Mount the proximity reader using the self-tapping screws and wall plugs provided.
- Ensure that the product is installed in a dry and safe location.
Please read the manual carefully before installing this unit
Packing list
Name | Quantity | Remarks |
---|---|---|
Proximity reader | 1 | |
Infrared remote | 1 | |
Admin add card | 1 | |
Admin delete card | 1 | |
User manual | 1 | |
Self-tapping screws | 2 | Φ3.5mm×27mm, used for fixing |
Wall plugs | 2 | |
Screw driver | 1 | Star |
Diode | 1 | IN4004 (for relay circuit protection) |
Please ensure that all the above contents are correct. If any are missing, please notify us immediately
Description
The PN20 is a compact, waterproof standalone programmable access control proximity reader for up to 2000 users. It uses Atmel microprocessor ensuring maximum performance in any environment, and the low power circuit prolongs its service life. Users can be added and deleted via admin cards making it very simple to operate. The infrared remote control allows settings to be quickly changed, including altering the relay time.
Features
- Zinc alloy, anti-vandal powder coated housing
- Waterproof, conforms to IP66
- Supplied with a 50cm cable
- High-capacity memory, 2000 users
- Infrared remote control and manager cards for programming
- Red, yellow and green LEDs display the working status
- Pulse mode or toggle mode
- Adjustable door unlocking time
- Built in light dependent resistor (LDR) for anti-tamper
Specification
Operating voltage | 9-24Vdc |
---|---|
User capacity | 2000 |
Static consumption | <40mA |
Operating consumption | <100mA |
Card reading distance | 3-5cm |
Frequency | 125KHz |
Operating temperature | -40 to 60⁰C |
Operating humidity | 0% to 98% |
Lock output load | 2A |
Waterproof | IP66 |
Dimensions | 103 x 48 x 19 mm |
Installation
- Remove back plate from the reader using security driver supplied and use it to mark the two fixing holes and one cable hole.
- Drill the cable and fixing holes.
- Secure back plate to the wall using fixing screws and plugs provided.
- Thread cable through the hole and connect wires needed, wrap unused wires with insulating tape to prevent short circuit.
- Fit the reader into the back plate and replace retaining screw.
Wiring
Colour | Function | Description |
---|---|---|
Red | 12/24V + | 12/24V + DC regulated power input |
Black | GND | 12/24V – DC regulated power input |
White | NO | Relay normally open |
Brown | COM | Relay common |
Green | NC | Relay normally closed |
Yellow | OPEN | Exit button |
Lock
Install IN4004 diode across the lock +V and -V
Gate, door, etc.
Factory reset
Turn off the power to the unit. Press and hold the exit button whilst powering
the unit up. There will be 2 beeps and the LED will turn yellow, release the
exit button. Then read any two 125KHz cards, the first card will be the master
add card, the second card will be the master delete card, the LED will then
turn red and the reset is complete. The master code has now been reset to
123456, and factory default settings are restored.
Note: User data will not be deleted when performing a factory reset.
Sound & light indication
Operation | LED indicator | Buzzer |
---|---|---|
Standby | Red | |
Enter programming mode | Red flashing slowly | One beep |
In a programming menu | Yellow | One beep |
Operation error | Three beeps | |
Exit programming mode | Red | One beep |
Door unlocked | Green | One beep |
Alarm | Red flashing quickly | Alarming |
Programming
It is highly advised to keep a record of the User ID number and card number to allow for individual deletion of cards in the future, see the last page.
Add and delete users by master cards
Add users
Read master add card Read 1st user card Read 2nd user card … Read master add
card again
Cards are automatically assigned to the next available user ID
Delete users
Read master delete card Read 1st user card Read 2nd user card … Read master
delete card again
Programming with the infrared programmer
Please note the infrared receiver is near the LED so please point the
programmer there.
Set a new master code
1. Enter programming mode| * Master code #
123456 is default master code
---|---
2. Change master code| 0 New Master code # New Master code #
The admin code is any 6 digits
3. Exit programming mode| *****
Add user cards
1. Enter programming mode| * Master code #
123456 is default master code
---|---
2. Add a card user (Method 1)
The reader will automatically assign the card to the next available user ID number
| 1 Read card #
Cards can be added continuously without exiting programming mode
2. Add a card user (Method 2)
In this method a user ID number is allocated to a card. User ID number is any number between 1 & 2000. Only one user ID number per card.
| 1 User ID number # Read card #
Cards can be added continuously without exiting programming mode
2. Add a card user (Method 3)
In this method the card is added by the 8 or 10 digit card number printed on the card. User ID number is automatically assigned.
| 1 Card number #
Cards can be added continuously without exiting programming mode
2. Add block of sequential card numbers
Allows manager to add up to 2000 cards with sequential numbers to the reader in a single step. Can take up to 3 minutes to program.
| 1 User ID number # Card quantity # First Card number #
3. Exit programming mode| *****
Delete user cards
1. Enter programming mode| * Master code #
123456 is default master code
---|---
2. Delete a card user by card| 2 Read card #
Cards can be deleted continuously without exiting programming mode
2. Delete a card user by user ID number
This option can be used when someone has lost their card
| 2 User ID number #
Cards can be deleted continuously without exiting programming mode
2. Delete a card user by card number
This option can be used when someone has lost their card
| 2 Card number #
Card number is 8/10 digits printed on the card. Cards can be deleted continuously without exiting programming mode
2. Delete ALL users| 2 Master code #
3. Exit programming mode| *****
Set relay configuration
1. Enter programming mode| * Master code #
123456 is default master code
---|---
2. Pulse mode
OR
2. Latch mode
| 3 1-99 #
The relay time is 1-99 seconds. (1 equals 50mS). Default is 5 seconds.
3 0 #
Read valid card, relay switches. Read valid card again, relay switches back.
3. Exit programming mode| *****
Set strike-out alarm
The strike-out alarm will engage after 10 consecutive failed card attempts.
Factory default is OFF. It can be set to deny access for 10 minutes or
activate the reader’s internal alarm.
1. Enter programming mode| * Master code #
123456 is default master code
---|---
2. Strike-out OFF
OR
2. Strike-out ON
OR
2. Strike-out ON (Alarm) Set alarm time
| 4 0 #
No alarm or lockout (default mode)
4 1 #
Access will be denied for 10 minutes
4 2 #
The device will alarm for the time set below
5 0-3 #
0-3 is the time in minutes. Default is 1 minute. Enter master code # or read valid card to silence
3. Exit programming mode| *****
Set audible and visual response
1. Enter programming mode| * Master code #
123456 is default master code
---|---
2. Control LED
Disable control LED
Enable control LED (default)
| ****
6 1 # Control LED indicator off in standby mode (still on when in programming and when a valid card is read)
6 2 # Control LED indicator on in standby mode (default)
2. Buzzer
Disable buzzer
Enable buzzer (default)
| ****
6 3 # No buzzer when card read (still buzzes when in programming, but not when exiting programming)
6 4 # Buzzer sounds when card read (default)
3. Exit programming mode| *****
User operation
To open the door:
Read valid card
To turn off alarm:
Read valid card or Enter master code#
Issue record
It is highly advised to keep a record (ideally digitally) of the User ID number and card number to allow for individual deletion of cards in the future.
Site| | Door location|
---|---|---|---
Card/fob number| User ID number| User name| Issue date
---|---|---|---
| | |
| | |
| | |
| | |
| | |
| | |
C Prox Ltd (inc Quantek)
- Unit 11 Callywhite Business Park, Callywhite Lane, Dronfield, S18 2
- XP +44(0)1246 417113
- sales@cproxltd.com
- www.quantek.co.uk
- Access Control Proximity Reader
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>