CONTRACTOR FIRMWARE UPDATE PROCESS
Connect the thermostat to Wi-Fi, and register to the customer’s account. After
registration is complete, the thermostat will check for any available firmware
updates available. You will see a drop down indicating a firmware update in
progress if there is one. Make sure the firmware is updated before installing
humidification accessories.
INSTALLATION – COMPATIBILITY AND WIRING
SENSI THERMOSTAT
| ****
CONVENTIONAL SYSTEM CONNECTION
| ****
HEAT PUMP SYSTEM CONNECTION
---|---|---
RC†| Power for cooling, 24V
RH†| Power for heating, 24V
C| Common wire, 24V
Y| 1st stage cool| 1st stage heat and cool (compressor)
Y2/| 2nd stage cool (or humidifier)| 2nd stage heat and cool (or humidifier)
W/E| 1st stage heat| 1st stage auxiliary/emergency heat (2nd stage heat)
W2/| 2nd stage heat (or dehumidifier)| 2nd stage auxiliary/emergency heat
(3rd stage heat or dehumidifier)
G| Indoor blower (fan)
O/B| Heat pump changeover, zone panel or 3-wire hot water zone valve
connection (configurable as O, B or 2 in the installer menu).| Heat pump
changeover (reversing valve) connection (configure as O or B in the installer
menu)
L| No function| “L” terminal connection
Humidification & Dehumidification Wiring Diagrams
1°WIRE HUMIDIFICATION & DEHUMIDIFICATION
- W2/* TERMINAL DEENERGIZES ON CALL FOR DEHUMIDIFICATION WITH CALL FOR COOL
- Y2/* TERMINAL ENERGIZES ON CALL FOR HUMIDIFICATION WITH CALL FOR HEAT
sTech tip:
1 wire control is typically used to energize one side of a solenoid coil that
already has the other side of a relay or solenoid coil attached to the common
on the 24 VAC HVAC transformer.
Wired Dehumidification
Thermostat terminal W2/* de-energizes on call for dehumidification to lower the fan speed. The DHM/ DHUM terminal is only used on systems with a compatible dehumidification feature that have the required terminal connection on the control module or have a relay installed to lower fan speed.
Tech tip:
Wired dehumidification cannot be configured with two stage heating systems. If
you’re unable to configure the thermostat for wired dehumidification, use the
installer menu to make sure the HVAC Equipment for Indoor is set for single
stage.
RELAY INSTALLED
A relay can be installed as shown below to switch fan speed to the next lower
speed on a call for dehumidification from the thermostat. The reduction in air
flow allows the coil to remove more humidity from the air. The relay should be
rated for the blower motor load. Since this configuration reduces the air flow
in cooling, the anti-freeze-up control or equivalent is recommended to prevent
the air conditioning coil from freezing due to low air flow, dirty filters,
low refrigerant pressure, etc.
CONFIGURATION – SETTING HUMIDIFICATION/DEHUMIDIFICATION CONTROL CAPABILITY ON/OFF
CONFIGURATION MENU ITEMS REFERENCE
Menu item| Default| Options
Sleep Mode| Off| Turn sleep display mode on/off
Backglow| Off| Off / On
Home Screen Content| On| Indoor Humidity
On| Time of Day
°F| °F / °C
Schedule| –| 5 / 2 Day Schedule
Wi-Fi| –| Connect to Wi-Fi
About Thermostat| –| Model Number/Reset
Advanced Setup| | HVAC Equipment | Fan Mode Options
Set Up HVAC Equipment| AC2| Outdoor Setup AC1/AC2/HP1/HP2/None
EL2| Indoor Setup GA1/GA2/EL1/EL2/Fan
O| Reversing Valve Position O/B/6/None
None| Additional Accessories None/Add
No| Humidifier (wired to thermostat) Yes/No
No| Dehumidifier (wired to thermostat) Yes/No
Fan Mode Options| Off| Circulating Fan Off/On
10% – 100% (5% increments)
Humidify| Off 40%| Humidification Off/On 5%- 50% (5% increments)
Dehumidify| Off 50%| Dehumidification Off/On 40% – 95% (5% increments)
- Press Advanced Set Up
- Press Set Up HVAC Equipment
- Make selections depending on the installed equipment
- Press Add Additional Accessories, and press Yes for either a wired humidifier or a wired dehumidifier. Then press Save.
Note:
If you’re unable to toggle Yes then you are utilizing second-stage
heating/cooling. Go back to the main HVAC Equipment menu and configure for
single-stage heating/cooling.
USING THE FEATURE – TURNING HUMIDIFICATION CONTROL ON/OFF AND SETTING THE
HUMIDITY SETPOINT
Adjust the humidification/dehumidification feature from either the thermostat
or the Sensi app.
In the Advanced Set Up menu, the Humidify and Dehumidify feature controls are available. Humidification Press Humidifiy. In the Humidification menu, toggle the feature on or off. With Humidification on, adjust the set percentage to maintain using the up/down arrows. Press the back arrow button after you’re done. Wired Dehumidification Press Dehumidify. In the Dehumidification menu, toggle the feature on or off. With Dehumidification on, adjust the set percentage to maintain using the up/down arrows. Press the back arrow button after you’re done. Note: If you have selected wired dehumidification in the “HVAC Equipment” settings, then the overcooling option will not be there, only the wired dehumidifier option.
Dehumidification – Overcooling
If you don’t have an accessory installed for wired dehumidification, you can
still use your cooling system to dehumidify your space. Press Dehumidifiy. In
the Dehumidification menu, toggle the feature on or off. With Dehumidification
on, adjust the set percentage to maintain using the up/down arrows. Press the
back arrow button after you’re done.
Note:
This allows your cooling system to run longer, up to 3 degrees past your set
temperature, to remove moisture.
Adjusting the humidity control from the Sensi app Open the Sensi app.
- Tap your thermostat name.
- Tap the settings gear.
- Tap System settings.
- Scroll to the humidity control section and adjust the percentage as needed or toggle the feature on/off.
Frequently asked questions
FAQ ANSWER
When can I get the firmware OTA update for humidity control?
|
OTA updates are pushed via Wi-Fi after being registered to the customer’s account on the Sensi app.
Which versions of Sensi thermostats are compatible with humidity control?
|
Sensi Touch (1F95U) and Sensi (1F87U) smart thermostats are all backward compatible. 1F86U and UP500W models are currently not compatible.
What terminals should I use to enable humidity control?
|
Use Y2/ for humidification and W2/ for dehumidification.
What types of humidifiers and dehumidifiers are supported?
|
Humidifiers: Any 24VAC humidifier. Currently, Sensi does not support independent (call for heat) humidification.
Dehumidifiers: HVAC systems with dehumidify mode (slowing of the system’s fan speed) or 24VAC dehumidifiers. Currently Sensi does not support independent (call for cool) dehumidification.
What is an appropriate humidity setpoint?
|
Depending on the outdoor temperature, the ideal indoor humidity level is between 30-50% RH. In cold weather, if condensation appears on your windows, lower the humidity setpoint.
What is overcooling to dehumidify?
|
On air conditioning systems without a dehumidifier, the dehumidification feature allows Sensi to overcool to a maximum of 3⁰ below the AC setpoint to help control the humidity. Overcooling is an option to dehumidify without having to wire additional accessories.
Why is my system unable to reach my humidity setpoint?
|
During extremely cold and dry or hot and humid climates, your humidifier or dehumidifier may not be able to increase or decrease humidity enough to reach your setpoint depending on the size of your equipment.