Luxpro PSDH021Ba NON-PROGRAMMABLE THERMOSTAT Instalation Manual
- October 30, 2023
- LUXPRO
Table of Contents
- `
- Luxpro PSDH021Ba NON-PROGRAMMABLE THERMOSTAT
- FEATURES
- INSTALLATION
- SETUP OPTIONS
- COMPLETING THE INSTALLATION
- FRONT PANEL ITEMS
- OPERATING INSTRUCTIONS
- BATTERIES AND MAINTENANCE
- TECHNICAL ASSISTANCE
- WARRANTY
- WIRING DIAGRAM NOTES
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 1 Phillips screwdriver (small-medium)
`
`
Luxpro PSDH021Ba NON-PROGRAMMABLE THERMOSTAT
View all LUXPRO thermostat manual
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only. Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc.
IMPORTANT!
Please read all instructions carefully before beginning installation and save
for future reference. Before removing any wiring from your existing
thermostat, the wires must be labeled with their terminal designations. Ignore
the color of the wires since they may not comply with any standard.
Thank you for your confidence in our product. You should become fully acquainted with this thermostat before installing it for usage. Follow the installation procedures carefully, and one step at a time. This will save you time and minimize the chance of damaging either the thermostat or the systems that it controls. These instructions may contain information beyond that required for your particular installation. Please save these instructions for future reference.
COMPATIBILITY
- The PSDH021Ba thermostat can be used with most 24-volt: single-stage heat pumps, and 2 heat / 1 cool heat pump systems.
- This thermostat cannot be used to control: conventional heating and cooling systems, 3-wire zone valves, or 120/240 volt (line voltage) heating or cooling systems. Ask your dealer for other LUXPRO® thermostats to control those systems.
FEATURES
- Digital, Non-Programmable
- Battery Powered Only
- Set Temperature Range from 45°F to 90°F
- Clean, Attractive Design
- Large, Easy Read Display with LED Backlight
- Easy To Install
- F / C Selectable Temperature Display
- Fixed 5 Minute Minimum Run /Time For Compressor Protection
- Adjustable Temperature Stops
INSTALLATION
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.
CAUTION
This thermostat is protected against normal static electric discharges.
However, in extremely dry weather you should touch a grounded metal object
before touching the thermostat to minimize the risk of causing damage to the
unit.
TOOLS REQUIRED
-
1 Phillips screwdriver (small-medium)
- Drill with 3/16-in. (4.8mm) drill bit
- Wire stripper/cutter
CAUTION
Turn off the electricity to the appliance before installing or servicing the
thermostat or any part of the system. Do not turn the electricity back on
until the work is completed.
- Your thermostat is a precision instrument. Please handle it with care.
- Do not short (jumper) across the electric terminals on your heating or cooling equipment to test the system. This may damage the thermostat and void your warranty.
- All wiring must conform to all applicable local codes and ordinances.
- This thermostat is limited to a maximum of 1.5 amps, total current; a higher current may cause damage to the thermostat.
THERMOSTAT LOCATION
On replacement installations, mount the new thermostat in place of the old one
unless the conditions listed below suggest otherwise. On new installations,
follow the guidelines listed below.
- Locate the thermostat on an inside wall, at about 5 ft. (1.5m) above the floor, and in a room that is used often.
- Do not install it where there are unusual heating conditions, such as: direct sunlight, near a lamp, television, radiator, register, fireplace, on a wall opposite a stove, or that carries hot water pipes.
- Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room, or in a draft from a stairwell, door, or window.
- Do not locate where air circulation is poor, such as: in a corner or alcove, or behind an open door.
- Do not locate in a damp area. This can lead to corrosion that may shorten thermostat life.
- Do not install the unit until all construction work and painting has been completed.
REMOVING THE OLD THERMOSTAT
- Switch OFF the electricity to the heating/cooling equipment; then proceed with the following:
- Remove the front cover from your old thermostat. Most will simply pull straight off, while others may be fastened by screws.
- Take note of the letters printed near each of the wire terminals. Attach adhesive labels (enclosed) to each wire for identification by their terminal letter, not the color of the wire.
- Make sure the wires do not fall back inside the wall. Remove and label each wire one at a time, and do not allow the wires to touch each other or any parts of the thermostat.
- Loosen all screws on the old thermostat base, and remove it from the wall.
MOUNTING THE NEW THERMOSTAT
- Strip insulation leaving approximately 3/8 in. (10mm) of bare wire on the ends, and clean off any corrosion present.
- Fill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat while in use.
- Pull your new thermostat apart by applying pressure to the thumb tab on the bottom edge of the unit, while pulling the front and back halves apart from the bottom edge of the thermostat.
NOTE : If you are mounting the base to a soft material like plasterboard, or if you are using the old mounting holes, the screws may not hold. Drill a 3/16-in (4.8mm) hole at each screw location, and insert the plastic anchors provided.
WIRING INFORMATION
Complete heating or cooling system wiring can be found in the WIRE
IDENTIFICATION AND WIRING SCHEMATICS section of this instruction sheet. The
schematics show system components for brand-new installations or for un-
referenced wires.
CONNECTING THE WIRES
Clean bare wire ends must be inserted in between the black clamp and the brass
terminal as shown here. Securely tighten all electrical terminal screws (even
unused ones).
SETUP OPTIONS
If batteries are presently installed, remove them from the thermostat before proceeding with changing any of the options listed below. A table similar to the one shown here is printed on the thermostat’s circuit board.
JUMPER SETTINGS
There are 2 option jumpers located inside the thermostat on the circuit board.
These settings can be changed from their default values by removing the
corresponding black shorting cap and installing the cap so that it is
positioned on the adjacent pair of metal pins. A change to either of the
option jumpers will not be recognized unless the thermostat has been without
battery power for at least 2 minutes, and then power is restored again. Each
of these jumpers changes a different setup option. The choices for these
options are listed in a table printed on the circuit board and are also
printed adjacent to each individual setting jumper.
JP1 – FAHRENHEIT OR CELSIUS DISPLAY FORMAT: This setting controls
whether the temperature is shown in degrees on the LCD display screen.
JP2 – [B] OR [O] TERMINAL USAGE OPTION: This setting determines how the
thermostat will use the shared B/O terminal connection on the back plate.
Select the option to have the B/O terminal powered while in heat mode, and un-
powered while in cool and off modes. Select the position to have the B/O
terminal powered while in cool mode, and un-powered while in heat and off
modes. If you are not sure which way to set this option, consult the
manufacturer of your heat pump unit.
Once all optional jumper settings have been performed as described in the previous section, ensure that the thermostat has been without battery power for at least 2 minutes for the change to be recognized. Now install new batteries into the thermostat. When installing batteries, use two new Energizer® or DURACELL® “AA” size alkaline batteries only. Ensure that the batteries are installed in the proper direction as per the markings shown in the battery tray.
COMPLETING THE INSTALLATION
Install your new thermostat on its base. To do this, start with the bottom
tilted out towards you at first, and line up the two holes in the top of the
thermostat with the two hooks on the top of the back plate. Slowly pivot the
bottom of the thermostat towards the back plate and push firmly on the bottom
half of the thermostat until it is securely latched to the back plate. If the
two thermostat halves do not mate together easily, remove them and try again.
Do not attempt to force them together if they do not appear aligned properly.
NOTE: Before use, remove the plastic film (if present) that is
protecting the LCD display screen.
Turn the electrical power back ON to both your heating and/or cooling systems.
Verify that both systems are operating properly. When set to a high
temperature, the heating system should provide warm air after a short time in
Heat Mode. Likewise, the cooling system should provide cool air after a short
time when set to a low temperature in Cool Mode. Usually, sound from the
heater and/or cooling system units can be heard while either is running. Your
installation is now complete.
FRONT PANEL ITEMS
SYSTEM MODE SWITCH
The MODE switch has 4 positions: EMER, HEAT, OFF, and COOL. In the summer, set
the switch to COOL to control cooling. In the winter, set the mode switch to
HEAT to control heating; set the mode switch to EMER to control auxiliary
heating only (if equipped). In the EMER position, the heat pump compressor is
disabled. When set to OFF mode, the heating and cooling system will remain
off.
FAN MODE SWITCH
The FAN switch has 2 positions: AUTO and ON. In the AUTO position, the
operation of the blower fan is determined only by the on/off cycling of the
heating and cooling system. In the ON position, the system’s blower fan will
be commanded ON continuously at all times, even when the system mode switch is
in the OFF position.
PUSH BUTTONS
There are two push buttons to the right of the unit’s display screen. These
are used to adjust the set point temperature.
OPERATING INSTRUCTIONS
TEMPERATURE ADJUSTMENT
While in HEAT, COOL, or EMER modes, a single press on either the UP or DOWN
button causes the word “SET” to appear on the screen, and the set temperature
value on the screen to start flashing. When flashing, the set temperature can
be altered by pressing either the UP or DOWN button once per degree of change,
or by holding either button for at least two seconds to automatically
increment the set temperature quickly in the associated direction. Based upon
the relationship of the set temperature to the displayed ambient room
temperature, the thermostat will engage the first stage of either heating or
cooling, if a temperature demand is present. If there is a large thermal
demand present that is greater than the first stage of heating can
accommodate, then a second stage of heating (W2) will be activated, showing
the word “AUX” on the display screen. There is approximately a 4-minute delay
that is imposed between the activation of the first stage of heating, and the
second stage of heating.
DISPLAY ILLUMINATION
Pressing either set temperature button will illuminate the display. The light
will remain on for approximately 12 seconds. While the light is illuminated,
pressing any of the 2 push buttons will cause the light to remain on for
approximately 12 more seconds.
MINIMUM RUN/OFF TIME
This is determined by the thermostat and controls the minimum length of time
that the thermostat must remain with Heat or Cool either On or Off before it
will automatically switch to the alternate On or Off state. This feature
prevents rapid or short cycling and also provides compressor protection. The
duration of this delay is fixed at 5 minutes between on or off-load changes.
BATTERIES AND MAINTENANCE
The batteries in the thermostat should be replaced AT LEAST once per year, or sooner if the battery symbol appears in the lower right portion of the display screen. To replace the batteries in the thermostat, remove the body from the wiring base plate attached to the wall by pressing the thumb latch at the bottom center of the unit and swinging the front body out towards you, up and away from the base. Remove the used batteries from the battery tray and discard them appropriately. Install two new Energizer® or size Alkaline batteries into the battery tray. Observe the polarity markings shown in the battery compartment to ensure proper installation. When finished, hang the top of the unit by the tabs at the top corners of the base, and then snap the bottom of the unit into place. Do not use unnecessary force. If the body does not snap into place easily, remove the body, re-hang it from the tabs at the top, and try again.
TECHNICAL ASSISTANCE
If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our Technical Assistance Department at 856-234-8803 during regular business hours between 8:00 AM and 4:30 PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproproducts.com. Our website offers you answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.
WARRANTY
Limited Warranty: If this unit fails because of defects in materials or workmanship within three years of the date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to three years from the date of the original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the location from which the purchase was made, along with proof of purchase. Please refer to “Technical ASSISTANCE” before returning the thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from the installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. and Canada only.
(PSDH021Ba) ENGLISH – WIRE IDENTIFICATION AND WIRING SCHEMATICS
HEAT PUMP TERMINAL CROSS REFERENCE CHARTTABLEAU DE RÉFÉRENCE CROISÉE DE BORNE DE POMPE À CHALEUR TABLA DE REFERENCIA PARA LA TERMINAL DE LA BOMBA DE CALEFACCIÓN
HEAT PUMP BRANDMARQUE DE POMPES À CHALEUR
MARCA DE LA BOMBA DE CALEFACCIÓN
| CORRESPONDING TERMINALS BORNESCORRESPONDANTES
TERMINALES CORRESPONDIENTES
| TAPE OFF (NOT USED) RUBAN RETIRÉ(NON UTILISÉ)
DESPRENDIMIENTO (NO UTILIZADO)
| E| G| Y| R| O| W2| B| C| L|
ARCO / Friedrich| X2| G| Y| RC| | W2| B| C| L|
ARCO / Snyder General| E| G| Y| R| O| W1| | C| X|
BARD| E| G| Y1| R| | W2| B| X| L|
BARD, HP, WH, MHP, HPQ| E| G| Y| R| | W2| W1| X| L|
BDP / BRYANT| E| G| Y| R| O| W1| | C| F|
CARRIER| E| G| Y| R| O| Y1| | C| L|
CARRIER 5Q| to W2| G| Y, W1| R| O| W2| | C| L|
CARRIER 50Q, QT382| E| G| Y| R| O| W2| | C| L|
COLEMAN| | G| Y| RED| V| W2| | BLACK| |
GE BAY| X2| G| Y| R| O| W| | B| | T
HEIL-QUAKER / Whirlpool| | G| Y| R| O| W| | B| |
JANITROL / Goodman| E| G| Y| R| O| W2| | C| |
LENOX TYPICAL HP6| | F| M| V/VR| R| Y| | X| |
LENOX HP8| E| F| M| V/VR| R| Y| | X| |
LENOX HP9, 10| E| F| M| V/VR| R| Y| | X| L|
LENOX HP16, 18, 19| E| F| M| V/VR| R| Y| | X| L|
MAGIC CHEF PE| E| G| Y| R| O| W| | C| |
RHEEM / RUUD| E| G| Y| R| | W2| B| X| L|
SNYDER GENERAL H-R811| | G| Y| R| O| W1| | C| |
TRANE| X2| G| Y| R| O| W| | B| F| T
WEATHERKING| | G| W1| R| Y1| E| | C| |
WESCO| E| G| W1| R| Y1| W2| | C| |
WESCO / ADDISON| E| G| W1| R| O| | | X| |
WESTINGHOUSE H50| E| G| Y| R| O| W| | X| L1|
WESTINGHOUSE HE| | F| C| V/VR| | H2| Z| X| |
WHITE RODGERS| E| G| Y| R| O| W2| | C/X1| L|
YORK| | G| Y| R| O| W| | B| X|
WIRING DIAGRAM NOTES
- The DASHED lines in wiring diagram #1 are optional depending upon your system type. Single-stage heat pumps will not have wires present for the “E” or “W2” terminals. For a 2-Heat / 1-Cool system with NO Emergency heat wire, AUX heat will be connected to “W2”. A jumper wire may be placed in between the “E” and “W2” terminals to allow Emergency Heat Mode.
- For Heat Pumps, use either the “B” or “O” wire, NOT BOTH.
- If “Y” and “C” wires are both present, then “C” is a common wire. Do not connect this “C” wire to your thermostat.
- If you have a “B” wire in your system that is used as a common wire, connecting it to the “B/O” terminal on this thermostat may damage your system and/or the thermostat.
Luxpro PSDH021Ba NON-PROGRAMMABLE THERMOSTAT Instalation Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>