FUJITSU ARYA30LBTU Split Type Air Conditioner Duct Type User Manual

October 30, 2023
FUJITSU

FUJITSU  ARYA30LBTU Split Type Air Conditioner Duct Type

Product Specifications

  • Type: Cooling & Heating
  • Cooling Capacity: 8.5 kW (for ARYA30LBTU) and 9.4 kW (for ARYA36LBTU
  • Heating Capacity: 10.0 kW (for ARYA30LBTU) and 11.2 kW (for ARYA36LBTU)
  • Power Source: 230 V, 50 Hz
  • Cooling Running Current: 11.6 A (for ARYA30LBTU) and 12.8 A (for ARYA36LBTU)
  • Heating Running Current: 11.7 A (for ARYA30LBTU) and 13.6 A (for ARYA36LBTU)
  • Input Watts (Cooling): 2.65 kW (for ARYA30LBTU) and 2.93 kW (for ARYA36LBTU)
  • Input Watts (Heating): 2.68 kW (for ARYA30LBTU) and 3.10 kW (for ARYA36LBTU)
  • E.E.R. (Cooling): 3.21 kW/kW
  • E.E.R. (Heating): 3.73 kW/kW (for ARYA30LBTU) and 3.61 kW/kW (for ARYA36LBTU)
  • Starting Current: 15 A
  • Moisture Removal: 2.5 L/hr (for ARYA30LBTU) and 3.0 L/hr (for ARYA36LBTU)
  • Air Circulation (Indoor): 2,100 m3/hr
  • Air Circulation (Outdoor): 3,600 m3/hr (for ARYA30LBTU) and 4,000 m3/hr (for ARYA36LBTU)
  • Maximum Current: 17.0 A (for ARYA30LBTU) and 20.0 A (for ARYA36LBTU)
  • Fan Speed (Indoor Unit): Discrimination – High speed, Me speed, Low speed, Quiet
  • Fan Speed (Outdoor Unit): Discrimination – Speed
  • Noise Level: 42 dB (High speed), 37 dB (Med speed), 32 dB (Low speed), 29 dB (Quiet) for Indoor Unit; 53 dB (Cooling), 55 dB (Heating) for Outdoor Unit
  • Compressor Type: Hermetic type, Inverter, 4 poles, 3 phase, DC motor, Twin Rotary
  • Compressor Weight (with oil): 16.3 kg
  • Standard Refrigerant: 2,100 g
  • Refrigerant Type: R410A
  • Max Pipe Length : 50 m
  • Max Pipe Height: 30 m

Product Usage Instructions

The Split Type Air Conditioner Duct Type is designed to provide cooling and heating in a room. To use the product, follow the steps below:

  1. Install the indoor unit and outdoor unit in their respective locations.
  2. Connect the indoor and outdoor units with refrigerant pipes and electrical cables.
  3. Connect the indoor unit to a power source of 230 V, 50 Hz.
  4. Turn on the power and select the desired mode (cooling or heating) using the remote control provided.
  5. Adjust the temperature and fan speed using the remote control as per your requirement.
  6. When not in use, turn off the power and unplug the device from the power source.
  7. Regularly clean the air filters to maintain optimal performance of the product.

SPECIFICATIONS

ELECTRICAL DATA

TYPE Cooling & Heating
INDOOR UNIT ARYA30LBTU
OUTDOOR UNIT AOYA30LBTL
COOLING CAPACITY 8.5 kW
HEATING CAPACITY 10.0 kW
POWER SOURCE 230 V 50 Hz
RUNNING CURRENT Cooling
Heating 11.7 A
INPUT WATTS Cooling
Heating 2.68 kW
E.E.R. Cooling
Heating 3.73 kW/kW
STARTING CURRENT 15 A
MOISTURE REMOVAL 2.5 L/hr
AIRCIRCULATION INDOOR 2,100 m3/hr
AIRCIRCULATION OUTDOOR 3,600 m3/hr
MAXIMUM CURRENT 17.0 A

FAN SPEED

INDOOR UNIT

| Discrimination| MFG-45RVN| MFG-45RVN
---|---|---|---
High speed| 1,270 r.p.m.| 1,270 r.p.m.
Med speed| 980 r.p.m.| 980 r.p.m.
Low speed| 790 r.p.m.| 790 r.p.m.
Quiet| 630 r.p.m.| 630 r.p.m.
OUTDOOR UNIT| Discrimination| MFE-36TV| MFE-36TV
Speed| 850 r.p.m.| 950 r.p.m.

NOISE LEVEL

INDOOR UNIT

| High speed| 42 dB| 42 dB
---|---|---|---
Med speed| 37 dB| 37 dB
Low speed| 32 dB| 32 dB
Quiet| 29 dB| 29 dB
OUTDOOR UNIT| Cooling| 53 dB| 54 dB
Heating| 55 dB| 55 dB

Note : Static pressure : 47Pa Duct length : Inlet 1m, Outlet 2m

DIMENSIONS

INDOOR UNIT           H x W x D 270 x 1,135 x 700 mm
OUTDOOR UNIT       H x W x D 830 x 900 x 330 mm

WEIGHT

INDOOR UNIT         Gross / Net 47 kg / 40 kg
OUTDOOR UNIT      Gross / Net 70 kg / 62 kg

COMPRESSOR AND REFRIGERANT

COMPRESSOR TYPE

| Hermetic type, Inverter, 4 poles, 3 phase,

DC motor, Twin Rotary

---|---
DISCRIMINATION| 5KD240XAD21
WEIGHT (with oil)| 16.3 kg
STANDARD REFRIGERANT| 2,100 g
REFRIGERANT TYPE| R410A
MAX PIPE LENGTH| 50 m
MAX PIPE HEIGHT| 30 m
Pipe length FULL CHARGE| 20 m| 2,100 g
30 m| 2,500 g
40 m| 2,900 g
50 m| 3,300 g
ADDITIONAL CHARGE| 40 g/m

DIMENSIONS

INDOOR UNIT

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-2

OUTDOOR UNIT

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-3 FUJITSU-ARYA30LBTU-Split-
Type-Air-Conditioner-Duct-Type-fig-4

REFRIGERANT SYSTEM DIAGRAM

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-5

CIRCUIT DIAGRAM

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-6

INDOOR PCB CIRCUIT DIAGRAM

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-7

CONTROLLER PCB ASSEMBLY ( MAIN PCB )

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-8

POWER SUPPLY PCB ASSEMBLY

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-9

OUTDOOR PCB CIRCUIT DIAGRAM

INVERTER ASSEMBLY

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-10

CONTROLLER PCB ASSEMBLY ( MAIN PCB )

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-11

TRANSISTOR PCB ASSEMBLY

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-12

POWER SUPPLY PCB ASSEMBLY

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-13

CONDENSOR PCB ASSEMBLY

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-14

ERROR CONTENTS

REMOTE CONTROL UNIT

  • Troubleshooting at the remote control LCD
  • This is possible only on the wired remote control.
  • If an error occurs, the following display will be shown.(“EE” will appear in the set room temperature display.)
Code Error contents

01  13

26  27

|

Indoor signal error

00| Wired remote controller abnormal
02| Indoor room temperature sensor error
04| Indoor heat exchanger temperature sensor (middle) error
28| Indoor heat exchanger temperature sensor (inlet) error
09| Float switch operated
0C| Outdoor discharge pipe temperature sensor error
06| Outdoor heat exchanger temperature sensor (outlet) error
0A| Outdoor temperature sensor error
15| Compressor temperature sensor error
1d| 2-way valve temperature sensor error
1E| 3-way valve temperature sensor error
29| Outdoor heat exchanger temperature sensor (middle) error
20| Indoor manual auto switch abnormal
2A| Power supply frequency detection error
17| IPM protection
18| CT error
1A| Compressor location error
1b| Outdoor fan error
1F| Connected indoor unit abnormal
1c| Outdoor unit computer communication error
12| Indoor fan abnormal
0F| Discharge temperature error
24| Exessive high pressure protection on cooling
2c| 4-way valve abnormal
16| Pressure switch abnormal
2b| Compressor temperature error
19| Active filter abnormal
25| PFC circuit error

ERROR CONTENTS

OUTDOOR UNIT
CAUTION
Always turn on the power 12 hours prior to the start of the operation in order to ensure compressor protection

  1. Make a TEST RUN in accordance with the installation instruction sheet for the indoor unit.
  2.  OUTDOOR UNIT LEDS
    When a malfunction occurs in the outdoor unit, the LED on the circuit board lights to indicate the error. Refer to the following table for the de- scription of each error according to the LED. LED| ERROR CONTENTS
    ---|---
    FLASH (0.1sec ON/0.1sec OFF)| Temperature sensor error
    FLASH (0.5sec ON/0.5sec OFF)| IPM protection
    FLASH (2sec ON/2sec OFF)| Current trans. error
    FLASH (5sec ON/5sec OFF)| Outdoor fan error

FLASH (0.1sec ON/2sec OFF)

| Compressor rotor position cannot be detected
FLASH (5sec ON/0.1sec OFF)| ACTPM error

Lighting

| Overheat discharge temperature protection

SPECIAL INSTALLATION SETTING
PUMP DOWN (Refrigerant collecting operation)
Perform the following procedures to collect the refrigerant when moving the indoor unit or the outdoor unit.

  1. Press the push-button switch on the circuit board once.

    • The LED on the circuit board starts flashing (one second ON/one se-cond OFF). This indicates the start of PUMP DOWN operation.
    • When the switch is pressed while the compressor is in operation, PUMP DOWN operation starts automatically.
    • When the switch is pressed while the compressor is in stop, the com-pressor starts to operate automatically, and then move on to PUMP DOWN operation.
  2. PUMP DOWN operation continues for about 1 minute. When PUMP DOWN operation is completed, the compressor stops automatically.
    Then close the 2-way valve and 3-way valve immediately.

  3.  Turn the power off.

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-16
DANGER : This part (Choke coil) generates high voltages. Never touch this part.

PARTS

INDOOR UNIT

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-17

Ref.| Description| Part number|
---|---|---|---
1| Intake Cover Sub Assy| 9374512010|
2| Main Panel Sub Assy| 9374511013
3| Drain Pan Sub Assy| 9374513017
4| Drain Cap| 9356541007
5| Evaporator Total Assy| 9374517510
6| Outlet Panel Sub Assy| 9374510016
7| Cabinet R Sub Assy| 9374508020
8| Control Cover A Sub Assy| 9374516018
9| Cabinet L Sub Assy| 9374509010
10| Intake Frame Assy| 9374216017
—| Distributor Assy| 9371325439
—| Coupling Pipe Assy| 9371333052
—| Seal Panel Sub Assy| 9374515011
—| Bracket Pipe Sub Assy| 9374514014
—| Thermo Holder Pipe| 313714262805
—| Thermistor Spring A| 313728262708

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-18

Ref.| Description| Part number|
---|---|---|---
21| Casing B| 9374234011|
22| Sirocco Fan Assy| 9356531046
23| Base Sub Assy| 9374504015
24| Separate Wall Assy| 9374228010
25| Casing A| 9374233014
26| Bracket Motor Assy| 9374230013
27| Motor Mount| 9378002012
28| Fan Motor| 9602466016
29| Bracket (Eva) R| 9374207015
—| Bracket (Eva) L| 9374208012
—| Panel (Control Box)| 9374210015
—| Cap (Power)| 9352173011
—| Motor Band| 9378031012

Control unit

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-19

Ref.| Description| Part number|
---|---|---|---
41| Controller PCB Assy (30)| 9707393293|
41| Controller PCB Assy (36)| 9707393309
42| Power Supply PCB Assy| 9707398069
43| Cap (Power)| 9352173011
44| One Touch Bush| 9374407019
45| Terminal 3P| 9703345012
46| Terminal 3P| 9306489045
47| Reactor Assy| 9707457018
48| Control Box A| 9374219018
49| Control Cover B| 9374222018
—| Control Box B| 9374220014
—| Room Thermistor| 9703299025
—| Pipe Thermistor| 9703297021
—| Remote Control| 9372266199
—| Wire Assembly| 9372714010

OUTDOOR UNIT

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-20
FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-21
FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-22
FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-23

Ref.| Description| Part number|
---|---|---|---
1| Top Panel Sub Assy| 9374417032|
2| Front Panel| 9374094066
3| Fan Guard| 9374330010
4| Grip Side| 9374173013
5| Service Panel Sub Assy| 9374415052
6| Right Panel Sub Assy| 9374416127
7| Emblem Rear| 9351355005
8| Valve Cover| 9374174010
11| Base Assy| 9374166138|
---|---|---|---
12| Condenser A Sub Assy| 9374420230
13| Separate Wall| 9374413188
14| Fan Motor| 9602717019
15| Propeller Fan Assy| 9366378020
21| Accumulator| 9385005006|
---|---|---|---
22| 4-Way Valve| 9900164010
23| Solenoid| 9970055034
24| Pressure Switch| 9900186012
25| Compressor Assy| 9372558126
26| Accumulator Support Assy| 313986353804
27| Check Joint Assy| 9372802038
28| Expansion Valve Assy| 9370947144
29| Coil (Expansion Valve)| 9900057039
30| 3-Way Valve Assy| 9377959010
31| 3-Way Valve Assy| 9377958013
32| Inlet Pipe (Cond) A Assy| 9373461067
33| Outlet Pipe (Cond) A Assy| 9374266104
34| Strainer Assy| 9372524015
Ref.| Description| Part number|
---|---|---|---
41| Inverter Case| 9375314019|
42| TR PCB Assy (IPM)| 9707669039
43| ACTPM| 9707592016
44| Choke Coil| 9900366018
45| Capacitor PCB Assy| 9707257021
46| PCB Case Assy| 9375316020
47| Controller PCB Assy (30)| 9707667059
47| Controller PCB Assy (36)| 9707667066
48| Power Supply PCB Assy| 9707128161
49| Terminal| 9900203023
50| Thermistor| 9704265012
51| Discharge Thermitor| 9900461003
52| Thermistor (Outdoor)| 9900463007
53| Compressor Thermistor| 9900466008
54| Heat Exchanger Thermistor| 9900462000
55| Wire (Pressure Switch)| 9367595082

ACCESSORIES

INDOOR UNIT

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-24

OUTDOOR UNIT

OPTIONAL PARTS

FUJITSU-ARYA30LBTU-Split-Type-Air-Conditioner-Duct-Type-
fig-26

Documents / Resources

| FUJITSU ARYA30LBTU Split Type Air Conditioner Duct Type [pdf] User Manual
ARYA30LBTU, AOYA30LBTL, ARYA36LBTU, AOYA36LBTL, ARYA30LBTU Split Type Air Conditioner Duct Type, Split Type Air Conditioner Duct Type, Air Conditioner Duct Type, Conditioner Duct Type
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FUJITSU User Manuals

Related Manuals