Braeburn 5000 Programmable Thermostats Installation Guide
- October 30, 2023
- Braeburn
Table of Contents
- Braeburn 5000 Programmable Thermostats
- Specifications
- InstallationReplacing Existing Thermostat
- Testing Your New Thermostat
- programming User Settings
- Setting Current Time of Day and Day of Week
- Setting Your Energy Saving Program
- Temperature Adjustment
- Additional Operation Features
- Battery Replacement
- Troubleshooting
- LIMITED WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Braeburn 5000 Programmable Thermostats
View all Braeburn thermostat manual
WARNING
- Always turn off the power to the air conditioning or heating system prior to installing, removing, cleaning or servicing thermostats.
- This thermostat requires either 24 Volts of AC Power or two (2) properly installed “AA” alkaline batteries for normal operation and control of the heating or cooling system.
- This thermostat requires two (2) properly installed “AA” alkaline batteries to retain the clock setting in the event of loss of AC Power due to a power outage or rolling blackouts when used as a hardwired thermostat.
- This thermostat should only be used as described in this manual. Any other use is not recommended and will void the warranty.
Specifications
Compatibility: Compatible with low voltage single-stage gas, oil or electric heating or cooling systems, including single-stage heat pumps. This thermostat can also be used on 250mv to 750mv millivolt heating-only systems.
- Terminations: Rc, Rh, B, O, Y, W, G, C 1 Specifications cont.
- 2 Installation MODEL Single Stage Heat / Cool
- 7-Day or 5 – 2 Day Programmable
- Electrical Rating: 24 Volt AC (18-30 Volt AC)
- 1 amp maximum load per terminal
- 3 amp total maximum load (all terminals)
- Control Range: 45˚ – 90˚ F (7˚ – 32˚ C)
- Accuracy: +/- 1˚ F (+/- .5˚ C)
- AC Power: 18-30 Volt AC
- DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)
InstallationReplacing Existing Thermostat
Most thermostats have three parts
- The cover may snap or hinge over the existing thermostat.
- The electronics or body, control the existing system.
- The sub-base, where the wires attach through the wall to the existing system.
- Always turn off power to the air conditioning and heating system prior to removing the existing thermostat.
- Carefully remove the cover and electronics body from the old thermostat sub-base. Depending on the brand, these parts may pull off or need to be unscrewed. The old sub-base should remain wired and on the wall until steps 4 and 5.
- Label every old wire with the letter of the connection to which the wire is attached. Example letters are R, M, Y, etc. Depending on the brand of the old thermostat, your letters may be different.
- After labeling the old wires, loosen each connection and remove them from the old sub-base. Secure the wires to prevent them from slipping into the hole in the wall.
- Remove the old sub-base from the wall, again being careful that the wires do not slip into the hole in the wall.
- Use the chart below to determine the new thermostat connections. As an example, if the old thermostat had a G or F connection, it goes to G on the new thermostat. Using a pencil and the chart below, circle the letter of each wire removed from the old thermostat
Old Terminal from Existing Thermostat| New Terminal for New
Thermostat| Terminal Description
---|---|---
V or RC| Rc| Cooling Transformer
M, 4, Rh or R| Rh| Heating Transformer
B| B| Reversing Valve (Heating)
O| O| Reversing Valve (Cooling)
Y| Y| Cooling Control
H, W or 4| W| Heating Control
G or F| G| Fan Control
C| C| 24 Volt AC, Transformer Common
NOTE: This thermostat is designed for use with 24 Volt AC low voltage single-stage gas, oil or electric heating or cooling systems, including single-stage heat pumps. This thermostat can also be used on 250mv to 750mv millivolt heating-only systems. Do not use this thermostat on applications with voltages above 30 Volts AC.
Installing Your New Thermostat
NOTE: When installing this thermostat in a new location, following a few
simple guidelines and the applicable building codes will give the best
results. Install the thermostat in a location that provides good airflow by
avoiding areas behind doors, near corners, air vents, direct sunlight or heat-
generating devices. The wiring must conform to all building codes and
ordinances as required by local and national code authorities having
jurisdiction for this installation.
- Always turn off the power to the air conditioning and heating system prior to installing this thermostat.
- Locate the release latch on the bottom (not the back) of the thermostat. Press the release latch in and separate the body from the sub-base of the thermostat.
- Set the thermostat electronics and cover them down on a clean surface. Place the sub-base on the wall in the desired location.
- Using the slotted mounting holes in the sub-base, mark the placement of the mounting holes through the slots and onto the wall. Insure the wires come out of the wall into the center hole of the sub-base.
- After verifying the drill will not damage items in the wall, use a 3/16 drill to create the mounting holes. Gently tap the supplied plastic anchors into the holes in the wall.
- Place the thermostat sub-base against the wall in the desired location. Ensure the thermostat is level, the wires are inserted in the opening, and the mounting holes are aligned with the slots on the sub-base.
- Fasten the sub-base to the wall using the supplied screws into the plastic wall anchors.
- Connect wires to the quick wiring terminal blocks. Use the wiring diagram chart to insure the old and new connections are correct.
- To prevent electrical shorts and potential damage to the thermostat, make sure all wire connections are secure and not touching each other.
- Turn the thermostat body over, exposing the rear view of the circuit board.
- Locate the internal °F / °C switch on the circuit board. Using your fingers, flip the switch toward the preferred temperature °F / °C scale.
- Locate the internal fan option switch, HG (Gas) / HE (Elec) on the circuit board. This switch controls the heating system fan delay. Select gas for gas or oil-fired systems. This will allow the furnace to run for a few seconds before starting the fan. Select electric for systems with electric furnace elements that require the fan to come on immediately. Using your finger, flip the switch toward the HG (Gas) or HE (Elec).
- Locate the internal NORM HP switch on the circuit board. This switch configures the thermostat for normal (NORM) heating and cooling systems or heat pump (HP) systems. Using your fingers, flip the switch toward the NORM or HP.
- Locate the internal programming switch on the circuit board. This switch configures the programming mode for either 5-2 DAY (weekday-weekend), or full 7 DAY programming. Using your finger, gently flip the switch toward the programming option that best suits your schedule.
- Ensure the cover is still installed on the thermostat body, and install the unit onto the sub-base. To do so, use the mounting tabs on the top of the sub-base as a guide hinge, and close up the thermostat case by pivoting the body and cover closed. The latch on the bottom of the thermostat will click when the case is properly closed.
- Flip the front thermostat cover open and open the battery compartment door. (continued on page 3 continued from page 2)
- Locate the positive [+] ends of the batteries and match them with the positive [+] terminals located in the battery compartment. Install the two new “AA” alkaline batteries (supplied). Close the battery compartment door.
- Restore system power and proceed to Test Your New Thermostat.
NOTE: If batteries were installed prior to accomplishing steps 10 through 15, you will need to reset the thermostat to register thermostat switch configurations prior to programming any user settings. Gently press the RESET button on the front of the thermostat using a paper clip or a small pencil tip.
Testing Your New Thermostat
- Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation. This could damage the thermostat and void the warranty.
- Do not select the COOL mode of operation if the outside temperature is below 50˚ F (10˚ C). This could possibly damage the controlled cooling system and may cause personal injury.
- This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect the compressor. This protection is also present in the heat mode of operation on single-stage heat pump systems.
NOTE : Test your thermostat prior to programming any user settings. Pressing The RESET button will erase any user entries previously programmed and return them to their default values
- Place the system switch in the HEAT position.
- Press the button on the keypad until the set point temperature setting is a minimum of 3 degrees higher than the current room temperature. The heating system should start within several seconds. The fan may not turn on immediately due to the heating system’s built-in fan delay.
- Place the system switch in the OFF position. The heating system should stop within several seconds on normal single-stage heating or cooling systems. On single-stage heat pump systems, you must wait 5 minutes for the automatic compressor short cycle protection period to expire or press the RESET button to bypass this feature for initial testing purposes. Pressing the RESET button will erase any user entries for time of day, day of the week, option settings and programming if previously programmed.
- Place the system switch in the COOL position.
- Press the button on the keypad until the set point temperature is a minimum of 3 degrees lower than the current room temperature.
- The cooling system should start within several seconds. Place the system switch in the OFF position. The cooling system should stop within a few seconds.
- Place the fan switch in the ON position. The system blower should start.
- Place the fan switch in the AUTO position. The system blower should stop.
programming User Settings
Default Thermostat Settings
Function | Status After Reset |
---|---|
Operation Mode | Normal Operating Mode |
Temperature Hold | Extended and Temporary Hold Cleared |
Clock | 12:00 p.m., Monday |
Room Temperature | 70˚ F (21.0˚ C), to be renewed within 5 seconds |
Set Point Temperature | According to System Switch 62˚ F (17.0˚ C) for Heat |
and Off 83˚ F (28.0˚ C) for Cool
Temperature Scale| ˚F or ˚C dependent on switch setting
Operating Program| DAY program, Monday
Low Battery Warning| Off, to be renewed within 5 seconds
Temperature Differential| 0.5˚ F (0.25˚ C)
Short Cycle Protection Timer| Reset
Output Relays| Off
Extended Hold| Indefinite
Keypad Lock| Unlocked
Adaptive Recovery Mode| Off
Residual Cooling Fan Delay| 60 seconds
Filter Check Monitor| 0 days-off
Setting Current Time of Day and Day of Week
Programming User Settings cont
NOTE: It is important for you to set the current time of day (note AM/PM
indicator in the display), and the current day of the week correctly to avoid
problems with program execution.
- When in normal operating mode, press the DAY/TIME keypad button. The LCD display will be cleared except for the time, am/pm indicator, and the day of the week. The hour portion of the time will flash.
- Press the or button to set the current hour.
- Press the DAY/TIME button again, and the minute portion of the time will flash.
- Press the or button to set the current minute.
- Press the DAY/TIME button again. The day of the week indicator will flash.
- Press the or button to set the current day of the week.
- Press the DAY/TIME button again and the thermostat will return to normal operating mode.
NOTE: The thermostat will return to normal operating mode automatically after 30 seconds if no key is pressed. It will also return to normal operating mode immediately if the RETURN button is pressed.
Setting Thermostat User Options
The default user options are compatible with most systems and applications.
They are normally set at the time of installation and usually do not require
modification under normal operating conditions. If you wish to change these
settings, simply follow the instructions below.
NOTE: The temperature differential settings are the same for both the
heating and cooling systems.
Setting the Temperature Differential
The default setting is 0.5˚ F (0.25˚ C). The room temperature must change 0.5˚
F (0.25˚ C) from the set point temperature before the thermostat will call for
heating or cooling.
- In normal operating mode, press and hold the RETURN button for 4 seconds. The LCD display will show “d1 X”, where “X” equals the ˚F / ˚C differential setting. This is the current temperature differential setting.
- Press the or button to set the temperature differential to your desired setting of 0.5˚, 1˚, or 2˚ F (0.3˚, 0.5˚, or 1˚ C).
NOTE : Once you have finished setting the temperature differential you can wait 30 seconds and the thermostat will automatically return to normal operation mode. Otherwise, you can press the RETURN button again to set the Residual Cooling Fan Delay. When you go directly to the next programming step, it is not necessary to press and hold RETURN for 4 seconds.
Setting Residual Cooling Fan Delay
The default setting is 60 seconds. During the COOL mode of operation, the fan will stay on for 60 seconds after the set point temperature has been satisfied, and the compressor has shut off.
- In normal operating mode, press and hold the RETURN button for 4 seconds. Press RETURN again until “FAN XX” is displayed where “XX” is the fan delay time in seconds.
- Press the or button to change the Residual Cooling Fan Delay to the desired setting of 0 (disabled), 30, 60, or 90 seconds.
- Press the RETURN button again to set the Extended Hold Time or wait 30 seconds for the thermostat to return to the normal mode.
Setting the Extended Hold Time (see section 7)
The default setting is Long (indefinite) Hold. If the HOLD feature is
activated, the current set point will be held until HOLD is released.
- In normal operating mode, press and hold the RETURN button for 4 seconds. Press RETURN repeatedly until “HOLD LG” is displayed where “LG” is indefinite hold. (continued on page 6)Setting the Extended Hold Time (continued)
- Press the or button to change the Extended Hold time from indefinite (LG) to 24 hours (SH).
- Press the RETURN button again to set the Filter Check Monitor or wait 30 seconds for the thermostat to return to normal mode.
Setting Filter Check Monitor (see section 7)
The default setting is 0 days (Filter Monitor disabled).
- In normal operating mode, press and hold the RETURN button for 4 seconds. Press RETURN repeatedly until “XXX FLT SET” is displayed where “XXX” is the Filter Monitor interval (number of days since last warning).
- Press the or button to change the Filter Monitor interval to the desired value of 0 (disabled), 30, 60, 90, 120, or 180 days. Press the RETURN button again to set adaptive recovery mode or wait 30 seconds for the thermostat to return to normal mode.
Setting Adaptive Recovery Mode (ARM™) (see section 7)
The default setting is OFF (Adaptive Recovery Mode disabled).
- In normal operating mode, press and hold the RETURN button for 4 seconds. Press RETURN repeatedly until “REC XX SE” is displayed where XX is the Adaptive Recovery Mode status.
- Press the or button to change the Adaptive Recovery Mode to either ON or OFF.
- Press the RETURN button again or wait 30 seconds for the thermostat to return to normal mode.
Setting Your Energy Saving Program
- It is important for you to set the current time of day (note the AM/PM indicator in the display), and the current day of the week correctly to avoid problems with program execution. This must be done prior to entering any program settings.
- The heating and cooling programs have both separate set point times and set point temperatures.
- This thermostat is preprogrammed with weekday and weekend set point times and temperatures. These settings provide efficient energy savings during normal heating and cooling modes of operation. If you wish to use the settings in the table, no further programming is necessary. Review these time and temperature settings prior to establishing your personal program settings to maximize your savings, and minimize programming requirements.
| Time: 6:00 am| Time: 6:00 am
---|---|---
| |
MORN| Heat: 70˚ F (21˚ C)| Heat: 70˚ F (21˚ C)
| Cool: 75˚ F (24˚ C)| Cool: 75˚ F (24˚ C)
| Time: 8:00 am| Time: 8:00 am
DAY| Heat: 62˚ F (17˚ C)| Heat: 70˚ F (21˚ C)
| Cool: 83˚ F (28˚ C)| Cool: 75˚ F (24˚ C)
| Time: 6:00 pm| Time: 6:00 pm
EVE| Heat: 70˚ F (21˚ C)| Heat: 70˚ F (21˚ C)
| Cool: 75˚ F (24˚ C)| Cool: 75˚ F (24˚ C)
| Time: 10:00 pm| Time: 10:00 pm
NIGHT| Heat: 62˚ F (17˚ C)| Heat: 62˚ F (17˚ C)
| Cool: 78˚ F (26˚ C)| Cool: 78˚ F (26˚ C)
- Make sure you place the system switch in the HEAT or COOL modes of operation as appropriate. You should not enter a program in the OFF position.
- When the system switch is in the COOL or HEAT modes of operation, the appropriate indicator will appear in the LCD display when the system is running. When the system switch is in the OFF mode the display will indicate OFF.
NOTE: For 7-day programming, the defaults follow the Weekday programming
shown above. To change between 5-2 and 7-day programming, adjust the switch by
following step 14 of the Installation section.
Entering Your Program – 5-2 Day Mode The 5-2 Day mode has separate Weekday and
Weekend Program Groups that allow you to change the daily set point times and
temperatures to meet your individual schedule needs. Weekday – allows you to
program all the weekdays (M, TU, W, TH, F will show in the display) at the
same time. Allows programming times and temperature settings for four set
points (MORN, DAY, EVE, and NIGHT) to meet your weekday schedule needs.
Weekend – allows you to program all the weekend days (SA, SU will show in the
display) at the same time. Again allows programming times and temperature
settings for four set points (MORN, DAY, EVE and NIGHT) to meet your weekend
schedule needs. (continued on page 8)
- Place the system switch in the HEAT mode of operation.
- Press the PROG button to enter the Program setting mode. MORN set point of the Weekday Program Group will be displayed. The display will show M, TU, W, TH, F to indicate the Weekday group is being programmed. The hour and the AM/PM indicator will be flashing.
- Press the or button to change the time to the desired hour in one-hour increments. Press the PROG button. The minute portion of the set point time will begin flashing.
- Press the or button to change the time to the desired minute in 10-minute increments. Press the PROG button. The SET temperature will begin flashing.
- Press the or button to change the set point temperature to the desired setting in 1º (.05˚ C) increments. Press the PROG button. The thermostat will now display the DAY set point time and temperature. Again, you will see the hour and the AM/PM indicator flashing.
- Follow steps 3 through 5 to set the set point times and temperatures for the periods of DAY, EVE and NIGHT.
- After pressing the PROG button, you will enter the Weekend Program Group. The display will show SA, SU to indicate the Weekend Group is being programmed. The hour portion of the MORN set point time and the AM/PM indicator will be flashing.
- Follow steps 3 through 6 to set the set point time and temperatures for the periods of MORN, DAY, EVE, and NIGHT.
- Place the system switch in the COOL mode of operation. The display will show COOL. Follow steps 2 through 8 to program the set point times and tempera- tures for the Weekday and Weekend groups in the COOL mode.
NOTE: To erase all entered programs, the current time of day, day of the week, and other user settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values.
Entering Your Program – 7-Day Mode
The 7-Day mode has separate Whole Week or Individual Day programming to allow
you to change the daily set point times and temperatures to meet your
individual schedule needs. The Whole Week programming can be used to set the
main portion of your schedule, allowing you to later modify specific days of
the week as required using the Individual Day programming capabilities. Whole
Week – allows you to program all seven days (M, TU, W, TH, F, SA, SU will show
in the display) at the same time. Then you can use the individual day
programming to fine tune your program for the few set point times or
temperatures that you may wish to change. Individual Days – allows you to
program each day of the week individually to give you the greatest schedule
flexibility. Often used to fine tune programming after initial programming.
(continued on page 9)
Entering Your Program – 7 Day Mode (continued from page 8)
IMPORTANT NOTE! When in Whole Week programming, the thermostat will
check if all of the days of that group have the same program set point times
and temperatures. If so, the set point time and temperature of the individual
set point will be displayed. Otherwise, the individual set point time and
temperature will be blanked. The user is allowed to change the daily programs
for this set point time and temperature by pressing the or button. This will
reset all the daily programs of the group for that specific individual set
point time and temperature to the startup default for that set point.
Continued pressing of the or button by the user will change set point time and
temperature settings as desired.
- Place the system switch in the HEAT mode of operation.
- Press the PROG button to enter Program setting mode. The MORN set point of the Whole Week Program Group will be displayed. The display will show M, TU, W, TH, F, SA, SU, indicating the whole week is being programmed. The hour and the AM/PM indicator will be flashing.
- If you wish to program each day individually press the DAY/TIME button to select a specific day.
- Press the or button to change the time to the desired hour in one-hour increments. Press the PROG button. The minute portion of the set point time will begin flashing.
- Press the or button to change the time to the desired minute in 10-minute increments. Press the PROG button. The SET temperature will begin flashing.
- Press the or button to change the set point temperature to the desired setting in 1º (.05˚ C) increments. Press the PROG button. The thermostat will now display the DAY set point time and temperature. Again, you will see the hour and the AM/PM indicator flashing.
- Follow steps 4 through 6 to set the set point times and temperatures for the periods of DAY, EVE, and NIGHT.
- Place the system switch in the COOL mode of operation. The display will show COOL. Follow steps 2 through 7 to program the set point times and temperatures for the COOL mode.
NOTE: To erase all entered programs, the current time of day, day of the week, and other user settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values.
Temperature Adjustment
Review Set Temperature
- Press and hold the or button. The current set point temperature will be displayed in place of the current room temperature and the indicator SET will be displayed.
- The display will return to normal operating mode when the or button is released. Continuing to hold the or button for 1 second or longer will allow the user to temporarily override the current programmed set point.
Temporary Program Override
- Press and hold or button for 1 second or longer. The entire display will flash once and the SET indicator will b displayed. Release the or button nd press the or button again as desired to adjust the set temperature.
- The display will return to normal operating mode after 15 seconds or you can press the RETURN button.
- The program indicator (MORN, DAY, EVE or NIGHT) will be flashing in the display, indicating that a Temporary Program Override is in effect. The Temporary Program Override will reset when the next set point time occurs or after four hours– whichever comes first.
Extended Hold (Vacation) Mode
- Press the HOLD button to bypass the program schedule. At the current set point temperature will be held either permanently or for 24 hours, depending on the setting selection made in section 4.
- Press the HOLD button again to return the thermostat to the normal program operation.
- The hold period will last until the hold is released as in step number 2 above, or is limited to 24 hours if the default was changed in the User Options Settings (see section 4).
Additional Operation Features
Filter Check Monitor (see section 4)
The Filter Check Monitor displays a reminder for required filter replacement or cleaning by flashing the FILT segment in the display. See instructions on your filter or heating/cooling unit for recommendations for interval settings. When the selected interval has been reached and required cleaning or replacement has been performed, press the RETURN button in any normal mode to reset the timer and turn off the warning.
Locking the Keypad
To prevent accidental or undesired adjustment of the thermostat, the Keypad The Lockout feature disables the operation of the keypad except for the backlight key. I order to lock the keypad, press and hold both buttons together at the same time for 5 seconds. The LOCK segment in the display will flash once per second and then appear continuously in the display. The keypad is now locked. To unlock the keypad, press and hold the buttons together at the same time for 1 second. The LOCK segment will disappear and the keypad will become unlocked.
Adaptive Recovery Mode (ARM™) (see section 4)
In order to maximize comfort and energy efficiency, this thermostat is
equipped with an Adaptive Recovery Mode (ARM™). This feature minimizes the
amount of time required by the heating or cooling system to reach the new set
point after a setback period is completed and assures your desired temperature
is achieved at your set program times. This feature activates when recovering
room temperature from setback programs to comfort programs, so it will only
take place when the current (heating) program set point temperature is lower
than the upcoming program set point temperature, or the current (cooling)
program set point temperature is higher then the upcoming program set the
point temperature. During ARM™, room temperature is recovered gradually by
turning on the heating or cooling before the end of the setback period. The
set point temperature is changed to that of the upcoming comfort program
temperature. The start time of recovery is based on the difference between the
current room temperature and the upcoming comfort program set point
temperature. The recovery to the upcoming set point starts 10 to 15 minutes
before the upcoming set point time for each degree of temperature change
required, up to a maximum of 2 hours in the HEAT mode, 3 hours in the COOL
mode. ARM™ does not operate when the unit is in HOLD mode, or if the program
is temporarily overridden
Circulating Fan Mode–Fan Operation
- AUTO: The fan operates as required by the heating or cooling system.
- When heating or cooling is not active, the fan will run as needed to ensure
- 35% minimum run time.
- ON: Fan will run at all time
Compressor Protection
This thermostat includes an automatic compressor protection feature to avoid
potential damage to the cooling system from short cycling. This thermostat
automatically provides a 5-minute delay after turning off the cooling system
output to protect the compressor. This protection is also present in the heat
mode of operation on single-stage heat pump systems to protect the compressor.
NOTE: The installer can reset the thermostat and bypass the compressor
protection features by pressing the RESET button. This will erase all entered
programs, the current time of day, day of the week, and other user settings
and should only be used during installation for testing purposes or to reset a
thermostat to regain normal operation. This will return all thermostat
settings to their default values.
Low Battery Detection
This thermostat requires two (2) new, properly installed “AA” Alkaline
batteries to maintain the system clock and to provide proper thermostat power
when 24-volt AC power fails or is not connected to the thermostat. When the
batteries start to become too weak to provide proper operation, the thermostat
will begin to display a low battery indicator. The low battery indicator is
provided to inform the user when the batteries require immediate attention. We
recommend replacing the batteries as soon as the low battery indicator
appears. If the batteries are not replaced after the low battery indicator
first appears the thermostat may not provide proper heating or cooling system
operation. Even if the low battery indicator does not appear, the batteries
should be replaced at least once a year, or if you plan on leaving the
premises for over a month. This thermostat can be powered by 24 volts AC or
battery power. To determine if 24-volt AC power is connected to the
thermostat, refer to the installation and wiring diagram section. If you
cannot determine how this thermostat is powered, call a professional service
technician to determine the type of installation and the proper operation of
your system.
Resetting the Thermostat
The Reset feature allows the user to completely reset the thermostat to
register new manual switch settings. To erase all entered programs, the
current time of day, the day of the week, and other user settings, gently
press the RESET button using a paper clip or a small pencil tip. This will
return all thermostat settings to their default values and register all new
manual switch settings for proper operation. Non-Volatile Memory In the event
of a power failure, the Non-Volatile Memory feature allows all settings to be
recovered, eliminating the need to reset the temperature and differential
settings. When AC power is restored after an outage, all settings are
retrieved from memory and reinstated.
Status Indicators
HEAT: This will turn on whenever the system switch is in HEAT mode.
“HEAT” will flash when the heating system is running.
COOL: This will turn on whenever the system switch is in cool mode.
“COOL” will flash when the cooling system is running.
Battery Replacement
Replacing the Batteries
- Open the thermostat cover and locate the battery compartment door.
- Remove the two “AA” alkaline batteries located in the battery compartment.
- Install two new “AA” alkaline batteries into the battery compartment. Make sure to match the positive (+) ends of the batteries with the positive (+) terminals located in the battery compartment.
- Close the battery compartment and verify that the low battery indicator does not appear in the display
Troubleshooting
- Symptom: The word HEAT or COOL is flashing in the thermostat display. Potential Solution: This indicates that the heating or cooling system is currently running. When these systems are not running, HEAT or COOL will not flash.
- Symptom: HEAT or COOL is flashing but the system is not running. Potential Solution: The thermostat is telling the heating or cooling system to run, but the system is not responding. You may need to call your local heating and air conditioning contractor.
- Symptom: The thermostat does not turn on the heating or cooling system. Potential Solutions: Check to see if OFF is shown in the display. This indicates that the system is turned off at the thermostat. Move the system selector switch to the HEAT or COOL position. After the compressor, short cycle protection 5-minute period expires the system should start. Compressor protection features may be in effect due to compressor short-cycle conditions. See section 7. The heating or cooling system may be malfunctioning. Call a professional service technician immediately to verify system operation.
- Symptom: The thermostat turns on heating instead of cooling or cooling instead of heating. Potential Solution: Check thermostat wiring to make sure that the heating and cooling stages are connected to the correct terminals on the wiring terminal block. See section 10.
- Symptom: The thermostat will not follow program set points. Potential Solutions: Check the current time of day, day of week program settings. Make sure to verify AM/PM indicator is accurately displaying desired time settings. See section 5. Check to see if OFF is shown in the display. This indicates that the system is turned off at the thermostat. Move the system selector switch to the HEAT or COOL position. After the compressor, short cycle protection period expires the system should start within several seconds. The thermostat program is in Extended Hold (Vacation) Mode and HOLD is showing in the display. Press the HOLD or RETURN button to release the permanent hold and return the thermostat to normal program operation.
- Symptom: The thermostat turns the heating or cooling system on too often or not often enough. Potential Solution: Increase or decrease the first-stage temperature differential setting as appropriate to provide the desired performance level. See section 4.
- Symptom: Low battery indicator is shown in the thermostat display. Potential Solution: Replace batteries immediately to maintain proper system operation. See section 8
- Symptom: HI is shown in the thermostat display where the room temperature is normally displayed. Potential Solutions: The temperature sensed by the thermostat is higher than the 99° F (37° C) upper limit of the thermostat’s display range. The display will return to normal after the sensed temperature lowers within the 40° to 99° F (4° to 37° C) display range. Turn on the cooling system or use other methods to lower the temperature.
- Symptom: LO is shown in the thermostat display where the room temperature is normally displayed. Potential Solutions: The temperature sensed by the thermostat is lower than the 40° F (4° C) lower limit of the thermostat’s display range. The display will return to normal after the sensed temperature rises within the 40° to 99° F (4° to 37° C) display range. Turn on the heating system to raise the temperature as needed for comfort within the room.
- Symptom: Cannot program a set point temperature higher than 90° F (32° C). Potential Solution: This is above the normal thermostat temperature setting range of 45° to 90° F (7° to 32° C).
- Symptom: Cannot program a set point temperature lower than 45° F (7° C). Potential Solution: This is below the normal thermostat temperature setting range of 45° to 90° F (7° to 32° C).
- Symptom: The thermostat will not allow set point changes. Potential Solution: The Keypad is locked. Press the key together at the same time for one second to unlock. See section 7.
- Symptom: Fan continues to run all the time whether the system is on or off. Potential Solution: Check that the fan control switch is in the AUTO position. This will allow the fan to run only when the heating or cooling system is turned on and running. Check the thermostat wiring to make sure that the fan control wiring is connected to the correct terminals on the wiring terminal block. See section 10.
- Symptom: Fan Runs intermittently or when the system is OFF. Potential Solution: The fan switch is in Circulate Mode. See section 4.
- Symptom: The room is too warm or too cold. Potential Solution: See section 4 of this manual to verify the current set point and make any modifications that are necessary.
- Symptom: The system turns on prior to the end of a setback period. Potential Solution: The thermostat is in Adaptive Recovery Mode. See sections 4 and 7
Wiring Diagrams
NOTE
- Transformer Common is not required for the battery-only operation of the thermostat.
- For heating or cooling-only systems, ignore the opposite connection.
- For 2-wire 24 Volt AC or 250mV – 750mV millivolt heating systems, ignore cooling connection and fan control.
Single Stage Conventional Systems (Dual Transformer)
NOTE: Transformer Common is not required for the battery-only operation of thermostat
NOTE:
- Transformer Common is not required for the battery-only operation of the thermostat.
- For units requiring reversing valve to be energized during heating, connect reversing valve to B terminal. For units requiring reversing valve to be energized during cooling, connect reversing valve to 0 terminal.
LIMITED WARRANTY
Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are due to faulty material or workmanship for a period of five years after the original date of purchase by a professional service technician. This warranty and our liability do not apply to batteries, nor does it include damage to merchandise or the thermostat resulting from accident, alteration, neglect, misuse, improper installation, or any other failure to follow Braeburn installation and operating instructions. Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period, with proof of the original date of purchase and a brief description of the malfunction. This limited warranty does not include the cost of removal or re-installation. This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province. Answers to any questions regarding our limited warranty may be obtained by writing our corporate offices.
WARRANTY FACILITY: Braeburn Systems LLC Attn: Warranty Department 2215
Cornell Avenue Montgomery, IL 60538 Braeburn Systems LLC
2215 Cornell Avenue Montgomery, IL 60538
Technical Assistance:
www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)
©2011 Braeburn Systems LLC All Rights Reserved Made in China 5000-100-009