Important Safety Information

WARNING!

  • Always turn off power to the air conditioning or heating system prior to installing, removing, cleaning or servicing thermostat.
  • Read this manual thoroughly prior to installing, programming or operating this thermostat.
  • This thermostat is designed for use with a 24 Volt-AC low voltage single stage gas, oil or electric heating or cooling systems.
  • Do not use this thermostat on applications with voltages above 30 Volts AC.
  • This thermostat requires two (2) properly installed “AA” alkaline batteries to maintain system clock during power outages.
  • The system must have 24 Volt AC power present for proper system operation and control.
  • Wiring must conform to all building codes and ordinances as required by local and national code authorities having jurisdiction.
  • Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation. This could damage the thermostat and void the warranty.
  • Do not select COOL mode of operation if the outside temperature is below 50° F (10° C). This could possibly damage the controlled cooling system and may cause personal injury.
  • This thermostat should only be used as described in this manual. Any other use is not recommended and will void the warranty.

SPECIFICATIONS

  1. Electrical Rating: 24 Volt AC (18-30 Volt AC)
    • 1 amp maximum load per terminal
    • 2 amp total maximum load (all terminals)
  2. Control Range: 45° – 90° F (7° – 32° C)
  3. Accuracy: +/- 1° F (+/- .5° C)
  4. AC Power: 18-30 Volts AC
  5. DC Back-Up Power: 3.0 Volts DC (2 AA alkaline batteries included)
  6. Compatibility with low voltage single-stage gas, oil, or electric heating or cooling\ systems, including single-stage heat pumps.
  7. Terminations: R, O, B, C, Y, W, G

INSTALLATION

Replacing Existing Thermostat
  1. Always turn off power to the air conditioning or heating system prior to removing the existing thermostat.
  2. Remove the cover of your old thermostat and locate the wire terminals. Do not remove wires from terminals yet.
  3. Using small pieces of masking tape, label wires prior to removal from terminals. Use Bthe chart below to determine the new terminal designations for your new thermostat.
    V or R| R| 24VAC
    ---|---|---
    O| O| Reverse Valve (Cooling)
    B| B| Reverse Valve (Heating)
    C| C| 24VAC common
    Y| Y| Cooling or Compressor for HP system
    H,W, or 4| W| Heating
    G or F| G| Fan Control
  4. After labeling and removing all wires from terminals, unscrew the existing thermostat sub-base from the wall. Make sure to secure wires to prevent them from slipping back into the hole in the wall.
    NOTE:  This thermostat is designed for use with a 24 Volt AC low voltage single-stage gas, oil, or electric heating or cooling systems, including single-stage heat pumps. Do not use this thermostat on applications with voltages above 30 Volts AC.

Installing Your New Thermostat

NOTE:  If you are installing this thermostat in a new installation be sure to locate the thermostat 4 to 5 feet above the floor in accordance with applicable building codes. Make sure to install the thermostat in a location that provides good airflow characteristics and avoid areas behind doors, near corners, air vents, direct sunlight or near any heat generating device. Installation in any of these areas could impact thermostat performance.

  1. Always turn off power to the air conditioning or heating system prior to installing your new thermostat.

  2. Place the system switch on front of the thermostat to OFF position.

  3. Place fan control switch on the front of the thermostat to the AUTO position.

  4. Remove front of the thermostat body from the sub-base by pressing release latch on the bottom of front body.

  5. Place the sub-base against wall in the desired thermostat location.

  6. Guide thermostat wires through center hole in the sub-base. Continue to hold sub-base against wall.

  7. Mark placement of mounting holes as appropriate and drill using a 3/16″ drill bit.

  8. Gently tap supplied plastic anchors into the holes in the wall.

  9. Place the thermostat sub-base against the wall in the desired location making sure the mounting holes are aligned as appropriate and the thermostat wires are properly inserting through opening in middle of the sub-base.

  10. Fasten the sub-base to wall using supplied screws.

  11. Connect wires to quick wiring terminal block as appropriate using the new terminal designations. Refer to Wiring Diagram section of this manual if required for assistance.

  12. Make sure all of the wire connections are secure and are not touching any other terminal to prevent electrical shorts and potential damage to the thermostat.

  13. Turn the front thermostat body over exposing the rear view of the circuit board.

  14. Locate the internal °F / °C switch on the circuit board.

  15. Using your fingers, gently flip the switch toward the preferred temperature °F / °C scale.

  16. Locate the internal fan option switch, HG (Gas) / HE (Elec) on the circuit board. This switch controls the heating system fan delay. Select gas for gas or oil fired systems.
    This will allow the furnace to run for a few seconds before initiating the fan. Select electric for systems with electric furnace elements that require the fan to come on immediately.

  17. Using your fingers, gently flip the switch towards the HG (Gas) or HE (Elec) selection that indicates the low voltage heating system the thermostat will control.

  18. Locate the internal NORM NON-HP / HP switch on the circuit board. This switch configures the thermostat for normal (NORM NON-HP) heating and cooling systems or heat pump (HP) systems.

  19. Using your fingers, gently flip the switch towards the NORM NON-HP or HP selection
    that indicates the low voltage heating system the thermostat will control.

  20. Attach the front body of the thermostat to the sub-base of the thermostat being careful to align the terminal pins on the front body with the terminal block on the sub-base.

  21. restore system power so you can test installation.

TESTING YOUR NEW THERMOSTAT

NOTE:  Test your thermostat prior to programming any user settings. Pressing the RESET button will erase any user entries for time of day, day of week, option settings and programming if previously programmed. This will return all user settings and return them to their default values. Remember, this will erase all programs entered by the user.
WARNING!  Read BEFORE Testing

  • Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation. This could damage the thermostat and void the warranty.
  • Do not select the COOL mode of operation if the outside temperature is below 50° F (10° C). This could possibly damage the controlled cooling system and may cause personal injury.
  • This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect the compressor. This protection is also present in the heat mode of operation on single-stage heat pump systems to protect the compressor. cont.
    NOTE:  If you installed the batteries prior to accomplishing steps 14 and 15, then you will need to reset the thermostat to register your thermostat switch configurations prior to programming. Gently press the RESET button on the front of the thermostat using a paper clip or a small pencil tip.
  1. Place the system switch in the HEAT position.
  2. Press the button on the keypad until the setpoint temperature setting is a minimum of 3 degrees higher than the current room temperature. The heating system should start within several seconds. The fan may not turn on immediately due to the heating system’s built-in fan delay.
  3. Place the system switch in the OFF position. The heating system should stop within several seconds on normal single-stage heating or cooling systems. On single-stage heat pump systems you must wait 5 minutes for the automatic compressor short cycle protection period to expire, or press the RESET button to bypass this feature for initial testing purposes. Pressing the RESET button will erase any user entries for time of day, day of week, option settings and programming if previously programmed.
  4. Place the system switch in the COOL position.
  5. Press the button on the keypad until the setpoint temperature is a minimum of 3 degrees lower than the current room temperature.
  6. The cooling system should start within several seconds. Place the system switch in the OFF position.
  7. Place the fan switch in the ON position. The system blower should start.
  8. Place the fan switch in the AUTO position. The system blower should stop.

PROGRAMMING

Default Thermostat Settings

Operation Mode Normal Operating Mode
Room Temperature 70˚ F (21.0˚ C), to be renewed within5 seconds
Setpoint Temperature According to system switch:62˚ F (17.0˚ C) for Heat or

Off 85˚ F (29.0˚ C) for Cool
Temperature Scale| ˚F or ˚C dependent on switch setting
Temperature Differential| 0.5˚ F (0.25˚ C)
Short Cycle Protection Timer| Reset
Output Relays| Off

Setting Thermostat Differential

The default settings for the temperature differential is compatible with most systems and applications. The temperature differential is normally set at time of installation and usually does not require any modification under normal operating conditions. If you feel that your system is turning on too often, simply follow the instructions below.
NOTE:  The temperature differential settings are the same for both the heating and cooling systems.
The default setting is 0.5° F (0.25° C). The room temperature must change by 0.5° F (0.25° C) from the setpoint temperature before the thermostat will initiate the system in heating or cooling.

  1. In normal operating mode, press and hold the RETURN button for 4 seconds. The LCD display will show “d1 x”, where “x” equals the °F / °C differential setting.
    This is the current temperature differential setting.

  2. Press the or button to set the temperature differential to your desired setting of 0.5°, 1°, or 2° F (0.25°, 0.5°, or 1° C).
    NOTE:  Once you have finished setting the temperature differential you can wait 15 seconds and the thermostat will automatically return to normal operation mode. Otherwise, you can press the RETURN to set the Extended Hold Time.
    To erase all user program settings, gently press RESET button using a paperclip or a small pencil tip. This will return all thermostat settings to their default values.

Review Set Temperature

  1. Press and hold or button. The current setpoint temperature will be displayed in the place of the current room temperature, and the indicator SET will be displayed.
  2. The display will return to normal operating mode when the or buttons are released. The SET indicator will turn off, indicating that the current temperature shown in the display is the room temperature. Continuing to hold the or button for 3 seconds or longer will allow the user to change the current setpoint temperature (See Changing Set Temperature).

Changing Set Temperature

  1. Press and hold or button for 3 seconds. The entire display will flash once and the SET indicator will be flashing. Release the or button and press the or button again as desired to adjust the set temperature.
  2. The display will return to normal operating mode after 5 seconds.
  3. The SET indicator will turn off in the display, indicating that the current temperature shown in the display is the room temperatureBraeburn-1010-Non-Programmable-Thermostat-fig.3

Compressor Protection Feature

This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect the compressor. This protection is also present in the heat mode of operation on single stage heat pump systems to protect the compressor.
NOTE:  The installer can reset the thermostat and bypass the compressor protection feature by pressing the RESET button. This will erase all user program settings and should only be used during installation for testing purposes or to reset a thermostat to regain normal operation. This will return all thermostat settings to their default values.

Non-Volatile Memory
In the event of a power failure, the non-volatile memory feature of this unit allows all settings to be recovered, eliminating the need to reset temperature and differential settings. When AC power is restored after an outage, all settings are retrieved from memory and reinstated.

Resetting Thermostat
The Reset feature allows the user to completely reset the thermostat to register new manual switch settings and return to factory set software settings.

  1. To erase all entered settings, gently press the RESET button using a paper clip or a small pencil tip.
  2. This will return all thermostat settings to their default values and register all new manual switch settings for proper operation.

TROUBLESHOOTING

**SYMPTOM ** POTENTIAL   SOLUTION ****
The thermostat does not turn on the heating or cooling system. Check to see

if  OFF is shown in the display. This indicates that the system is turned off at the thermostat. Move the system selector switch to the  HEAT  or COOL  position. After the compressor, short cycle protection 5-minute period expires the system should start within a minutes time.
| Compressor protection features may be in effect due to compressor short- cycle conditions. See the  Compressor   Protection   Feature  section for full explanation of this feature.
| The heating or cooling system may be malfunctioning. Call a professional service technician immediately to verify system operation.
Thermostat turns on heating instead of cooling, or cooling instead of heating.| Check thermostat wiring to make sure that the heating and cooling stages are connected to the correct terminals on the wiring terminal block. See  Installation and  Wiring Diagrams  sections of this manual.
Thermostat turns heating or cooling system on too often| Increase or decrease temperature differential setting as appropriate to provide the desired performance level. See the  Setting   Temperature   Differential section of this manual.
or not often enough.|
OFF is shown in thermostat display and heating or cooling system will not start.| This indicates that the system is turned off at the thermostat. The thermostat must be in  HEAT  or  COOL  modes of operation to control the heating or cooling system. Move the system selector switch to the HEAT  or  COOL  position.
|
|
HI is shown in the thermostat display where the room temperature is normally displayed.| The temperature sensed by the thermostat is higher than the 90˚ F (32˚ C) upper limit of the thermostats display range. The display will return to normal after the sensed temperature lowers within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. Turn on the cooling system or use other methods to lower the temperature accordingly.
__| This condition could occur from the system being turned off during an exceptionally warm period or upon installation when the thermostat has been stored for a long period of time in a warm vehicle or location prior to being installed. The thermostat is equipped with a mechanical high-temperature safety switch that will turn off the thermostat should the temperature exceed 99˚ F (37˚ C).
**SYMPTOM ****LO is shown in the thermostat display where the room temperature is normally displayed.| POTENTIAL   SOLUTION ** The temperature sensed by the thermostat is lower than the 45˚ F (7˚ C) lower limit of the thermostats display range. The display will return to normal after the sensed temperature rises within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. If the temperature in the controlled space seems to be normal, wait for the thermostat to acclimate to the correct room temperature. If the room seems to be colder than usual, turn on the heating system to raise the temperature as needed for comfort within the room.

This condition could occur from the system being turned off during a cold weather period or upon installation when the thermostat has been stored for a long period of time in a cold vehicle or location prior to being installed. The thermostat should be allowed to warm up prior to installation to allow proper heating control once installed.

---|---
Thermostat will not allow me to program a setpoint temperature higher than 90˚ F (32˚ C).| This is above the normal thermostat temperature setting range of 45˚ to 90˚ F (7˚ to 32˚ C).
Thermostat will not allow me to program a setpoint temperature lower than 45˚ F (7˚ C).| This is below the normal thermostat temperature setting range of 45˚ to 90˚ F (7˚ to 32˚ C).
Fan continues to run all the time whether the system is onor off.| Check that the fan control switch is in the  AUTO  position. This will allow the fan to run only when the heating or cooling system is turned on and running.Check thermostat wiring to make sure that the fan control wiring is connected to the correct terminals on the wiring terminal block. See  Installation  and Wiring   Diagrams  sections of this manual.
The room is too warm or too cold.| See  Review Set Temperature  section of this manual to verify the current setpoint and make any modifications that are necessary.

WIRING DIAGRAMS

Braeburn-1010-Non-Programmable-Thermostat-fig.7 NOTES

  1. For heating or cooling only system, ignore opposite connection.
  2. The common wire is required for the 1010 thermostat. The 1010 thermostat is NOT a power-stealing thermostat. Braeburn-1010-Non-Programmable-Thermostat-fig.8

WARRANTY

Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are due to faulty material or workmanship for a period of five years after the original date of purchase by a professional service technician. This warranty and our liability does not apply to batteries, nor does it include damage to merchandise or the thermostat resulting from accident, alteration, neglect, misuse, improper installation or any other failure to follow Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period, with proof of the original date of purchase and a brief description of the malfunction. This limited warranty does not include the cost of removal or re-installation. This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province. Answers to any questions regarding our limited warranty may be obtained by writing our corporate offices.
WARRANTY FACILITY: Braeburn Systems LLC Warranty Department 2215 Cornell Avenue Montgomery, IL 60538
Braeburn Systems LLC
2215 Cornell Avenue
Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.

Braeburn 1010 Non-Programmable Thermostat User Manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals