Braeburn 1010 Non-Programmable Thermostat User Mnaual
- October 30, 2023
- Braeburn
Table of Contents
Braeburn 1010 Non-Programmable Thermostat
View all braeburn thermostat manual
Important Safety Information
WARNING!
- Always turn off power to the air conditioning or heating system prior to installing, removing, cleaning or servicing thermostat.
- Read this manual thoroughly prior to installing, programming or operating this thermostat.
- This thermostat is designed for use with a 24 Volt-AC low voltage single stage gas, oil or electric heating or cooling systems.
- Do not use this thermostat on applications with voltages above 30 Volts AC.
- This thermostat requires two (2) properly installed “AA” alkaline batteries to maintain system clock during power outages.
- The system must have 24 Volt AC power present for proper system operation and control.
- Wiring must conform to all building codes and ordinances as required by local and national code authorities having jurisdiction.
- Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation. This could damage the thermostat and void the warranty.
- Do not select COOL mode of operation if the outside temperature is below 50° F (10° C). This could possibly damage the controlled cooling system and may cause personal injury.
- This thermostat should only be used as described in this manual. Any other use is not recommended and will void the warranty.
SPECIFICATIONS
- Electrical Rating: 24 Volt AC (18-30 Volt AC)
- 1 amp maximum load per terminal
- 2 amp total maximum load (all terminals)
- Control Range: 45° – 90° F (7° – 32° C)
- Accuracy: +/- 1° F (+/- .5° C)
- AC Power: 18-30 Volts AC
- DC Back-Up Power: 3.0 Volts DC (2 AA alkaline batteries included)
- Compatibility with low voltage single-stage gas, oil, or electric heating or cooling\ systems, including single-stage heat pumps.
- Terminations: R, O, B, C, Y, W, G
INSTALLATION
Replacing Existing Thermostat
- Always turn off power to the air conditioning or heating system prior to removing the existing thermostat.
- Remove the cover of your old thermostat and locate the wire terminals. Do not remove wires from terminals yet.
- Using small pieces of masking tape, label wires prior to removal from terminals. Use Bthe chart below to determine the new terminal designations for your new thermostat.
V or R| R| 24VAC
---|---|---
O| O| Reverse Valve (Cooling)
B| B| Reverse Valve (Heating)
C| C| 24VAC common
Y| Y| Cooling or Compressor for HP system
H,W, or 4| W| Heating
G or F| G| Fan Control - After labeling and removing all wires from terminals, unscrew the existing thermostat sub-base from the wall. Make sure to secure wires to prevent them from slipping back into the hole in the wall.
NOTE: This thermostat is designed for use with a 24 Volt AC low voltage single-stage gas, oil, or electric heating or cooling systems, including single-stage heat pumps. Do not use this thermostat on applications with voltages above 30 Volts AC.
Installing Your New Thermostat
NOTE: If you are installing this thermostat in a new installation be sure to locate the thermostat 4 to 5 feet above the floor in accordance with applicable building codes. Make sure to install the thermostat in a location that provides good airflow characteristics and avoid areas behind doors, near corners, air vents, direct sunlight or near any heat generating device. Installation in any of these areas could impact thermostat performance.
-
Always turn off power to the air conditioning or heating system prior to installing your new thermostat.
-
Place the system switch on front of the thermostat to OFF position.
-
Place fan control switch on the front of the thermostat to the AUTO position.
-
Remove front of the thermostat body from the sub-base by pressing release latch on the bottom of front body.
-
Place the sub-base against wall in the desired thermostat location.
-
Guide thermostat wires through center hole in the sub-base. Continue to hold sub-base against wall.
-
Mark placement of mounting holes as appropriate and drill using a 3/16″ drill bit.
-
Gently tap supplied plastic anchors into the holes in the wall.
-
Place the thermostat sub-base against the wall in the desired location making sure the mounting holes are aligned as appropriate and the thermostat wires are properly inserting through opening in middle of the sub-base.
-
Fasten the sub-base to wall using supplied screws.
-
Connect wires to quick wiring terminal block as appropriate using the new terminal designations. Refer to Wiring Diagram section of this manual if required for assistance.
-
Make sure all of the wire connections are secure and are not touching any other terminal to prevent electrical shorts and potential damage to the thermostat.
-
Turn the front thermostat body over exposing the rear view of the circuit board.
-
Locate the internal °F / °C switch on the circuit board.
-
Using your fingers, gently flip the switch toward the preferred temperature °F / °C scale.
-
Locate the internal fan option switch, HG (Gas) / HE (Elec) on the circuit board. This switch controls the heating system fan delay. Select gas for gas or oil fired systems.
This will allow the furnace to run for a few seconds before initiating the fan. Select electric for systems with electric furnace elements that require the fan to come on immediately. -
Using your fingers, gently flip the switch towards the HG (Gas) or HE (Elec) selection that indicates the low voltage heating system the thermostat will control.
-
Locate the internal NORM NON-HP / HP switch on the circuit board. This switch configures the thermostat for normal (NORM NON-HP) heating and cooling systems or heat pump (HP) systems.
-
Using your fingers, gently flip the switch towards the NORM NON-HP or HP selection
that indicates the low voltage heating system the thermostat will control. -
Attach the front body of the thermostat to the sub-base of the thermostat being careful to align the terminal pins on the front body with the terminal block on the sub-base.
-
restore system power so you can test installation.
TESTING YOUR NEW THERMOSTAT
NOTE: Test your thermostat prior to programming any user settings.
Pressing the RESET button will erase any user entries for time of day, day of
week, option settings and programming if previously programmed. This will
return all user settings and return them to their default values. Remember,
this will erase all programs entered by the user.
WARNING! Read BEFORE Testing
- Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation. This could damage the thermostat and void the warranty.
- Do not select the COOL mode of operation if the outside temperature is below 50° F (10° C). This could possibly damage the controlled cooling system and may cause personal injury.
- This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect the compressor. This protection is also present in the heat mode of operation on single-stage heat pump systems to protect the compressor. cont.
NOTE: If you installed the batteries prior to accomplishing steps 14 and 15, then you will need to reset the thermostat to register your thermostat switch configurations prior to programming. Gently press the RESET button on the front of the thermostat using a paper clip or a small pencil tip.
- Place the system switch in the HEAT position.
- Press the button on the keypad until the setpoint temperature setting is a minimum of 3 degrees higher than the current room temperature. The heating system should start within several seconds. The fan may not turn on immediately due to the heating system’s built-in fan delay.
- Place the system switch in the OFF position. The heating system should stop within several seconds on normal single-stage heating or cooling systems. On single-stage heat pump systems you must wait 5 minutes for the automatic compressor short cycle protection period to expire, or press the RESET button to bypass this feature for initial testing purposes. Pressing the RESET button will erase any user entries for time of day, day of week, option settings and programming if previously programmed.
- Place the system switch in the COOL position.
- Press the button on the keypad until the setpoint temperature is a minimum of 3 degrees lower than the current room temperature.
- The cooling system should start within several seconds. Place the system switch in the OFF position.
- Place the fan switch in the ON position. The system blower should start.
- Place the fan switch in the AUTO position. The system blower should stop.
PROGRAMMING
Default Thermostat Settings
Operation Mode | Normal Operating Mode |
---|---|
Room Temperature | 70˚ F (21.0˚ C), to be renewed within5 seconds |
Setpoint Temperature | According to system switch:62˚ F (17.0˚ C) for Heat or |
Off 85˚ F (29.0˚ C) for Cool
Temperature Scale| ˚F or ˚C dependent on switch setting
Temperature Differential| 0.5˚ F (0.25˚ C)
Short Cycle Protection Timer| Reset
Output Relays| Off
Setting Thermostat Differential
The default settings for the temperature differential is compatible with most
systems and applications. The temperature differential is normally set at time
of installation and usually does not require any modification under normal
operating conditions. If you feel that your system is turning on too often,
simply follow the instructions below.
NOTE: The temperature differential settings are the same for both the
heating and cooling systems.
The default setting is 0.5° F (0.25° C). The room temperature must change by
0.5° F (0.25° C) from the setpoint temperature before the thermostat will
initiate the system in heating or cooling.
-
In normal operating mode, press and hold the RETURN button for 4 seconds. The LCD display will show “d1 x”, where “x” equals the °F / °C differential setting.
This is the current temperature differential setting. -
Press the or button to set the temperature differential to your desired setting of 0.5°, 1°, or 2° F (0.25°, 0.5°, or 1° C).
NOTE: Once you have finished setting the temperature differential you can wait 15 seconds and the thermostat will automatically return to normal operation mode. Otherwise, you can press the RETURN to set the Extended Hold Time.
To erase all user program settings, gently press RESET button using a paperclip or a small pencil tip. This will return all thermostat settings to their default values.
Review Set Temperature
- Press and hold or button. The current setpoint temperature will be displayed in the place of the current room temperature, and the indicator SET will be displayed.
- The display will return to normal operating mode when the or buttons are released. The SET indicator will turn off, indicating that the current temperature shown in the display is the room temperature. Continuing to hold the or button for 3 seconds or longer will allow the user to change the current setpoint temperature (See Changing Set Temperature).
Changing Set Temperature
- Press and hold or button for 3 seconds. The entire display will flash once and the SET indicator will be flashing. Release the or button and press the or button again as desired to adjust the set temperature.
- The display will return to normal operating mode after 5 seconds.
- The SET indicator will turn off in the display, indicating that the current temperature shown in the display is the room temperature
Compressor Protection Feature
This thermostat includes an automatic compressor protection feature to avoid
potential damage to the cooling system from short cycling. This thermostat
automatically provides a 5-minute delay after turning off the cooling system
output to protect the compressor. This protection is also present in the heat
mode of operation on single stage heat pump systems to protect the compressor.
NOTE: The installer can reset the thermostat and bypass the compressor
protection feature by pressing the RESET button. This will erase all user
program settings and should only be used during installation for testing
purposes or to reset a thermostat to regain normal operation. This will return
all thermostat settings to their default values.
Non-Volatile Memory
In the event of a power failure, the non-volatile memory feature of this unit
allows all settings to be recovered, eliminating the need to reset temperature
and differential settings. When AC power is restored after an outage, all
settings are retrieved from memory and reinstated.
Resetting Thermostat
The Reset feature allows the user to completely reset the thermostat to
register new manual switch settings and return to factory set software
settings.
- To erase all entered settings, gently press the RESET button using a paper clip or a small pencil tip.
- This will return all thermostat settings to their default values and register all new manual switch settings for proper operation.
TROUBLESHOOTING
**SYMPTOM ** | POTENTIAL SOLUTION **** |
---|---|
The thermostat does not turn on the heating or cooling system. | Check to see |
if OFF is shown in the display. This indicates that the system is turned
off at the thermostat. Move the system selector switch to the HEAT or
COOL position. After the compressor, short cycle protection 5-minute
period expires the system should start within a minutes time.
| Compressor protection features may be in effect due to compressor short-
cycle conditions. See the Compressor Protection Feature section
for full explanation of this feature.
| The heating or cooling system may be malfunctioning. Call a professional
service technician immediately to verify system operation.
Thermostat turns on heating instead of cooling, or cooling instead of
heating.| Check thermostat wiring to make sure that the heating and cooling
stages are connected to the correct terminals on the wiring terminal block.
See Installation and Wiring Diagrams sections of this manual.
Thermostat turns heating or cooling system on too often| Increase or decrease
temperature differential setting as appropriate to provide the desired
performance level. See the Setting Temperature Differential
section of this manual.
or not often enough.|
OFF is shown in thermostat display and heating or cooling system will not
start.| This indicates that the system is turned off at the thermostat. The
thermostat must be in HEAT or COOL modes of operation to control
the heating or cooling system. Move the system selector switch to the
HEAT or COOL position.
|
|
HI is shown in the thermostat display where the room temperature is
normally displayed.| The temperature sensed by the thermostat is higher than
the 90˚ F (32˚ C) upper limit of the thermostats display range. The display
will return to normal after the sensed temperature lowers within the 45˚ to
90˚ F (7˚ to 32˚ C) display range. Turn on the cooling system or use other
methods to lower the temperature accordingly.
__| This condition could occur from the system being turned off during
an exceptionally warm period or upon installation when the thermostat has been
stored for a long period of time in a warm vehicle or location prior to being
installed. The thermostat is equipped with a mechanical high-temperature
safety switch that will turn off the thermostat should the temperature exceed
99˚ F (37˚ C).
**SYMPTOM ****LO is shown in the thermostat display where the room
temperature is normally displayed.| POTENTIAL SOLUTION ** The
temperature sensed by the thermostat is lower than the 45˚ F (7˚ C) lower
limit of the thermostats display range. The display will return to normal
after the sensed temperature rises within the 45˚ to 90˚ F (7˚ to 32˚ C)
display range. If the temperature in the controlled space seems to be normal,
wait for the thermostat to acclimate to the correct room temperature. If the
room seems to be colder than usual, turn on the heating system to raise the
temperature as needed for comfort within the room.
This condition could occur from the system being turned off during a cold weather period or upon installation when the thermostat has been stored for a long period of time in a cold vehicle or location prior to being installed. The thermostat should be allowed to warm up prior to installation to allow proper heating control once installed.
---|---
Thermostat will not allow me to program a setpoint temperature higher than 90˚
F (32˚ C).| This is above the normal thermostat temperature setting range of
45˚ to 90˚ F (7˚ to 32˚ C).
Thermostat will not allow me to program a setpoint temperature lower than 45˚
F (7˚ C).| This is below the normal thermostat temperature setting range of
45˚ to 90˚ F (7˚ to 32˚ C).
Fan continues to run all the time whether the system is onor off.| Check that
the fan control switch is in the AUTO position. This will allow the fan
to run only when the heating or cooling system is turned on and running.Check
thermostat wiring to make sure that the fan control wiring is connected to the
correct terminals on the wiring terminal block. See Installation and
Wiring Diagrams sections of this manual.
The room is too warm or too cold.| See Review Set Temperature section of
this manual to verify the current setpoint and make any modifications that are
necessary.
WIRING DIAGRAMS
NOTES
- For heating or cooling only system, ignore opposite connection.
- The common wire is required for the 1010 thermostat. The 1010 thermostat is NOT a power-stealing thermostat.
WARRANTY
Braeburn Systems LLC warrants each new Braeburn thermostat against any defects
that are due to faulty material or workmanship for a period of five years
after the original date of purchase by a professional service technician. This
warranty and our liability does not apply to batteries, nor does it include
damage to merchandise or the thermostat resulting from accident, alteration,
neglect, misuse, improper installation or any other failure to follow Braeburn
installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn
thermostat under warranty provided it is returned postage prepaid to our
warranty facility in a padded carton within the warranty period, with proof of
the original date of purchase and a brief description of the malfunction. This
limited warranty does not include the cost of removal or re-installation. This
warranty gives you specific legal rights and you may also have other rights
that vary from state to state or province to province. Answers to any
questions regarding our limited warranty may be obtained by writing our
corporate offices.
WARRANTY FACILITY: Braeburn Systems LLC Warranty Department 2215 Cornell
Avenue Montgomery, IL 60538