Product Information
The Athletics Switcher Outdoor is a device designed for use in outdoor environments for athletics events. It allows for the switching between cameras and tracks to capture the events as they happen. The device comes with a power cord and should only be used with the supplied charger or a type approved by Swiss Timing to prevent damage to the battery or unit.
It is important to follow safety precautions such as protecting the device against splashing, rain, and excessive sun rays. The device should not be used if it is damaged or insecure. Always verify that the voltage quoted on the rating plate is the same as your voltage and connect the device only to power sockets with protective earth.
The device should not be opened as there is nothing inside that needs servicing. Swiss Timing SA reserves the right to make improvements in the products described in this documentation at any time without prior notice.
The device should be disposed of properly by returning it to a local authorized collection system to contribute to the protection of the environment and human health.
Product Usage Instructions
- Connect the device to a power source using the supplied charger or a type approved by Swiss Timing.
- Protect the device against splashing, rain, and excessive sun rays.
- Verify that the voltage quoted on the rating plate is the same as your voltage and connect the device only to power sockets with +protective earth.
- Switch between cameras and tracks using the device’s controls.
- Do not open the device as there is nothing inside that needs servicing.
- Dispose of the device properly by returning it to a local authorized collection system.
Caution and safety precautions
- Never use any other charger than the supplied or a type approved by Swiss Timing. This could destroy the battery, cause damage to unit, and possible cause personal injury due to fire or/and electrical shock.
- Never bypass a power cord ground lead by breaking off the ground pin, or by using inappropriate extension cords or adapters.
- Never plug a power cord into the AC power source until you have made sure that all installation, cabling and power levels, are proper, and that the applicable procedures in this manual have been followed.
- Protect the equipment against splashing, rain and excessive sun rays.
- Never use the device if it is damaged or insecure.
- Verify the selection of the power distribution.
- Verify that the voltage quoted on the rating plate is the same as your voltage. Connect the appliance only to power sockets with protective earth. The use of incorrect connection voids warranty.
- This program may be modified at any time without prior notification.
- Do not open the case; there is nothing that needs servicing inside it. Nevertheless, if the case must be opened, you must call for some qualified personnel. The power supply cable must be disconnected before opening the case.
- During the transport of all Swiss Timing equipment delivered with a reusable carry case, the said case should be used at all times. This is imperative to limit the damage, such as shocks or vibration that can be caused to the units during transport.
- The same cases should also be used when returning equipment to Swiss Timing for repair. Swiss Timing reserves the right to refuse all guarantees if this condition is not fulfilled.
- If the installation includes a horn, be sure to maintain a sufficient security distance from the public.
Documentation Updates
Swiss Timing SA reserves the right to make improvements in the products
described in this documentation at any time without prior notice. Furthermore,
Swiss Timing SA reserves the right to revise this documentation in its content
at any time and without any obligation to notify any person or organization of
such revision.
Disclaimer
The information provided in this documentation has been obtained from sources
believed to be reliable, accurate and current. However, Swiss Timing SA makes
no representation or warranty, express or implied, with respect, but not
limited to, the completeness, accuracy, correctness and actuality of the
content of this documentation. Swiss Timing SA specifically disclaims any
implied warranty of merchantability, quality and/or fitness for any particular
purpose. Swiss Timing SA shall not be liable for errors contained in this
documentation or for incidental or consequential damages in connection with
the supply, performance or use of this documentation.
Environment
This symbol indicates that this product should not be disposed with household
waste. It has to be returned to a local authorized collection system. By
following this procedure you will contribute to the protection of the
environment and human health. The recycling of the materials will help to
conserve natural resources.
Copyright
© Swiss Timing SA
All rights reserved.
This documentation may not, as a whole or in part, be copied, translated,
reproduced, transmitted or reduced and/or stored to any electronic medium or
machine-readable form without the prior written consent of Swiss Timing SA
INTRODUCTION
The Athletics Switcher Outdoor (ASO) is a device for advanced competition level distributing input and output data of athletics devices and accessories.
It allows to connect and switch 2 photo finish (Primary & Secondary) cameras and laptops with false start system, timing scoreboards, wind gauge (sprint), finish photocells, headset, and additional RS422 output. Connection of additional photo finish camera infield (start & finish) is also available. Optional keyboard for intermediate photocells at 200m and 1500m. Power supply: 10-30VDC, external PSU 110-240 VAC/15VDC.
- Dedicated keyboard for photocell activation
- Possibility to connect 3 OSV cameras
- Data output can be switched between PRY and SDY cameras
- Switch start measurement command between PRY and SDY (wind gauge)
- Compatible with Mistral & Boreas wind gauge devices
- Wind speed and false start ASC data dispatched between PRY and SDY cameras
- OSV ready monitoring via 2 LEDs on Switcher Unit
- One interface with many functions
Material delivered
- 1x ATH Switcher outdoor
- 1x Photocell switcher (OPTION)
- 1x UTG cable 10m. (ATH Switcher to fix cabling box)
- 2x DIN cable 10m. (ATH Switcher to PRY & SDY cameras)
- 1x External power supply 100-240VAC / 15VDC
- 3x Power cable (EU / UK / US)
CONNECTIONS
Connections overview
Only one Start (StartTime) or False start (ASC) can be connected on the track.
All unused start systems must be disconnected.
You may only reconnect start system if necessary.
Front view
Rear View
Distribution of RS422 data
Distribution of START & FINISH contacts
CABLING
There are several possible cabling solutions and you will find some examples below.
Timing Room connections
Cameras connections
Cameras Primary & Secondary
Cameras Primary & Infield (Track) as Secondary
Cameras Primary & Secondary & Infield (Track)
Cameras Primary & Secondary & Infield (Track & Shadow)
Additional timer
An additional timer can be connected to the START and FINISH contacts trough
the INFIELD camera connector.
A specific cable is needed according to the timer model.
In this configuration, select the UNFIELD switch in position CELL. Do not
use pushbutton (MAN)
Rear panel description
Power 10-30VDC
There are 2 DC power inputs, the second one is used as Backup.
You can connect:
- 1 external power supply or 1 external battery 12VDC (POWER 1 or POWER 2)
- 2 external power supplies (POWER 1 and POWER 2)
- 1 external power supply and 1 external battery 12VDC (POWER 1 and POWER 2)
- 2 external batteries 12VDC (POWER 1 and POWER 2)
If only power supplies are connected to the ASO, add an Uninterruptable Power Supply (UPS).
Cameras
3 cameras can be connected to the ASO unit. Primary and Secondary cameras are positioned in the timing room and Infield could be installed in the track or in the control room as Shadow.
Select CELL if recording is started by FINISH photocell or MAN if started by a
pushbutton.
The pushbutton is connected in the two bananas plugs
USB computer connection.
Myria connection (START & FINISH)
To connect OSV STAR camera, please use adapter cable 3503.628.
Cell Switcher (OPTION)
Track
Galactica
Only the running time is transferred (same information as track scoreboards).
Telephone
OPERATING
Power on
When cabling is done as specified in previous chapters, switch on the unit by
pressing the ON button. The POWER leds will light up if power is connected.
Primary & Secondary Selection
Before the first race, select the switch in position Primary (PRY). When a
problem appears during the event, select the switch in position secondary
(SDY). Data will be immediately switched.
When camera Primary is READY, the corresponding led will light up. When camera Secondary is READY, the corresponding led will light up. The camera Infield READY is not displayed.
Photocell switcher (OPTION)
If intermediates times (200M – 400M – 1500M) are requested, connect the
Photocell Switcher to the Athletics Switcher.
A board will help you to select the correct intermediate time according to the
race length.
Intermediate time 200M or 1500M
When the first racer arrives near the intermediate photocell, press and hold
the intermediate button (200M or 1500M) until the racer crosses the photocell,
then release the button.
Intermediate time 400M (FINISH)
When the first racer arrives near the intermediate photocell, press the
intermediate button (FINISH). After the first racer has crossed the photocell,
release the button (FINISH).
Finish time
Before the end of the race, arm the FINISH photocell by pressing the FINISH
button. The button will light up as a confirmation of the FINISH.
After the last racer has crossed the photocell, release the button (FINISH).
The switch of the camera managing the running time should be selected on CELL.
USB CONNECTION
Install drivers
- Power on your computer and boot to Windows.
- Put the driver CD in the CD-ROM then run the PL-2303 driver (See Fig.1 and 2)
- Connect Athletics Switcher PRY or SDY with your computer by USB cable.
- Windows will auto detect four “new USB devices” and start Install Shield Wizard (See Fig.3)
- After driver installation, please follow the below process to verify whether the device was properly installed. Click Start – Setting — Control panel — double click system icon – Hardware Device Manager — Double click on ports (COM&LPT) (See Fig. 4).
- If the device has been correctly installed, you may see 4 ports new COM devices listing. This means Windows has assigned the device to the COM# port.
*There could be a difference in the port numbers of the Device Manager window, as the PL2303 driver will auto assign a COM number from your system.
Remove drivers
Use the DRemover98_2k to remove INT131 driver. Double click DRemover98_2k. If
INT131 driver software has already been installed, the modify, repair or
remove the program window will appear, then select “Remove” to clean INT131
driver completely.
It is necessary to update the driver when INT131 adds new features or functions. Use the DRemover98_2k to remove old version INT131 driver. Double click DRemover98_2k. If an older version of the INT131 driver software existed in the system, the modify, repair or remove the program window will appear, then select “Remove” to clean INT131 driver completely. Once the software has been removed, install the new software.
CONNECTORS DESCRIPTION
TECHNICAL SPECIFICATIONS
Mechanical characteristics
| Athletics Switcher| Photocells Switcher
---|---|---
Dimensions: :| 440 x 300 x 55 mm| 200 x 150 x 60 mm
Weight:| 3.7 kg| 0.6 kg
Protection:| IP42 (indoor use)
Working temperature:| 0°C to 50° C
Temperature range storage:| -30 to 85°C
Electrical characteristics
Power supply| External power supply :
Athletics Switcher :
| 110 – 240 VAC / 15VDC
10 – 30VDC
---|---|---
Power consumption:| Max. 90 VA
CE Standards:| CE
APPENDICE
Index figures
No table of figures entries found.
Version history
Version | Modifications since last version |
---|---|
1.0 | Initial version |
Swiss Timing LTD
P.O. Box 138, Rue de l’Envers 1 CH-2606 Corgémont – Switzerland
Phone +41 32 488 36 11
Email: info@swisstiming.com
Website: www.swisstiming.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>