F8001 COMETEO Universal Radiation Shield
COMETEO Universal Radiation Shield F8001
The COMETEO radiation shield F8001 is designed to protect temperature and humidity sensors with a diameter of 13 to 18 mm from thermal radiation and climatic influences. The shield is made of UV stabilized ASA and stainless steel, and weighs approximately 2.4 kg (without mounting clamps).
Dimensions
ie-snc-F8001-01
Radiation Shield Location
Place the radiation shield at least 1.8 m above the ground. If it is
necessary to mount the shield in close proximity to the building, it should be
on its north (shaded) side. For professional measurements, a grass place is
recommended that has no obstacles within a radius of 10 m (the lawn should be
maintained on an ongoing basis). The distance to the nearest building should
be more than four times the height of the building.
Radiation Shield Mounting
The package includes two clamps for fixing the shield. Attach the clamps to
a pipe with a diameter of 20 to 50 mm (vertical or horizontal) and then attach
the shield with the enclosed M8 nuts (see figure). The pipe should not
interfere with the space next to the shield.
ie-snc-F8001-01
Measuring Probe Installation
Insert the measuring probes into the glands at the bottom of the shield to
the recommended height (see figure) and tighten the nut to secure the probe.
Secure the cables with cable ties. Radiation shield F8001 is designed for
mounting one probe. The optional accessories (FP004) allows up to four probes
to be installed. Loosen the M4 nuts (see figure), remove the reflector plate
with the gland and screw on the plate with the four glands. Insert blanking
plugs in unused glands.
ie-snc-F8001-01
Technical Specification
- Diameter of the installed probe: 13 to 18 mm
- Fixing the shield: on a pipe with a diameter of 20 to 50 mm
- Temperature operating range:
- Relative humidity operating range: 0 to 100 %RH
- Storage temperature range:
- Storage relative humidity range: 0 to 100 %RH (no condensation)
Content of the Package
- 1 pc Radiation Shield F8001
- 2 pcs Clamps for fixing the shield
- 4 pcs M8 nuts for attaching the shield
- 4 pcs Blanking plugs for unused glands (if using optional accessories FP004)
End of Operation
The radiation shield should be disposed of according to current
legislation.
Technical Support and Service
Technical support and service is provided by the distributor. For contact,
see warranty certificate.
Warning
Installation, commissioning, and maintenance may only be carried out by
personnel with qualification by applicable regulations and standards. COMET
SYSTEM, Ltd. reserves the right to make technical changes to the device
without previous notice. Misprints reserved.
ie-snc-F8001-01
PRODUCT DESCRIPTION
The COMETEO radiation shield F8001 is designed for the protection of any temperature and humidity sensor with a diameter of 13 to 18 mm from thermal radiation and climatic influences.
DIMENSIONS
RADIATION SHIELD LOCATION
Place the radiation shield at least 1.8 m above the ground. If it is necessary
to mount the shield in close proximity to the building, it should be on its
north (shaded) side. For professional measurements, a grass place is
recommended that has no obstacles within a radius of 10 m (the lawn should be
maintained on an ongoing basis). The distance to the nearest building should
be more than four times the height of the building.
RADIATION SHIELD MOUNTING
The package includes two clamps for fixing the shield. Attach the clamps to a
pipe with a diameter of 20 to 50 mm (vertical or horizontal) and then attach
the shield with the enclosed M8 nuts (see figure). The pipe should not
interfere with the space next to the shield.
MEASURING PROBE INSTALLATION
Insert the measuring probes into the glands at the bottom of the shield to the recommended height (see figure) and and tighten the nut to secure the probe. Secure the cables with cable ties.
Radiation shield F8001 is designed for mounting one probe. The optional accessories (FP004) allows up to four probes to be installed. Loosen the M4 nuts (see figure), remove the reflector plate with the gland and screw on the plate with the four glands. Insert blanking plugs in unused glands.
TECHNICAL SPECIFICATION
- Diameter of the installed probe: 13 až 18 mm
- Fixing the shield: on a pipe with a diameter of 20 to 50 mm
- Temperature operating range: -40 až +65 ºC
- Relative humidity operating range: 0 až 100 %RH
- Storage temperature range: -40 až +65 °C
- Storage relative humidity range: 0 až 100 %RH (no condensation)
- Weight: approximately 2.4 kg (without mounting clamps)
- Material: UV stabilized ASA, stainless steel
CONTENT OF THE PACKAGE
- shield F8001 1 pc
- mounting clamp 2 pcs
- cable tie 4 pcs
- nut M8 4 pcs
END OF OPERATION
The radiation shield dispose according to current legislation.
TECHNICAL SUPPORT AND SERVICE
Technical support and service is provided by distributor. For contact see warranty certificate.
WARNING
Installation, commissioning and maintenance may only be carried out by
personnel with qualification by applicable regulations and standards.
© Copyright: COMET SYSTEM, s.r.o.
It is prohibited to copy and make any changes in this manual, without explicit
agreement of company COMET SYSTEM, Ltd. All rights reserved. COMET SYSTEM,
Ltd. makes constant development and improvement of their products.
Manufacturer reserves the right to make technical changes to the device
without previous notice. Misprints reserved.