F8004 Cometeo Universal Radiation Shield
Product Information
COMETEO Universal Radiation Shield
The COMETEO radiation shield F8004 is a device designed to protect up to 4 measuring probes with a diameter of 13 to 18 mm from thermal radiation and climatic influences. The shield is made of UV stabilized ASA and stainless steel, and weighs approximately 2.4 kg (without mounting clamps). The shield can be fixed on a pipe with a diameter of 20 to 50 mm. The temperature operating range is not specified, but the relative humidity operating range is between 0 and 100%RH. The shield should be disposed of according to current legislation.
PRODUCT Dimensions
The dimensions of the shield are not specified in the user manual.
Radiation Shield Location
The radiation shield should be placed at least 1.8 m above the ground. If it is necessary to mount the shield in close proximity to the building, it should be on its north (shaded) side. For professional measurements, a grass place is recommended that has no obstacles within a radius of 10 m (the lawn should be maintained on an ongoing basis). The distance to the nearest building should be more than four times the height of the building.
Radiation Shield Mounting
The package includes two clamps for fixing the shield. Attach the clamps to a pipe with a diameter of 20 to 50 mm (vertical or horizontal) and then attach the shield with the enclosed M8 nuts (see figure). The pipe should not interfere with the space next to the shield.
PRODUCT Measuring Probe Installation
Insert the measuring probes into the glands at the bottom of the shield to the recommended height (see figure) and tighten the nut to secure the probe. Secure the cables with cable ties. Insert blanking plugs in unused glands.
PRODUCT Technical Support and Service
- Technical support and service is provided by the distributor.
- For contact information, see the warranty certificate.
Warning
Installation, commissioning, and maintenance may only be carried out by personnel with qualification by applicable regulations and standards.
PRODUCT DESCRIPTION
- The COMETEO radiation shield F8004 is designed to protect up to 4 measuring probes with a diameter of 13 to 18 mm from thermal radiation and climatic influences.
DIMENSIONS
RADIATION SHIELD LOCATION/ MOUNTING
RADIATION SHIELD LOCATION
Place the radiation shield at least 1.8 m above the ground. If it is necessary to mount the shield in close proximity to the building, it should be on its north (shaded) side. For professional measurements, a grass place is recommended that has no obstacles within a radius of 10 m (the lawn should be maintained on an ongoing basis). The distance to the nearest building should be more than four times the height of the building.
RADIATION SHIELD MOUNTING
The package includes two clamps for fixing the shield. Attach the clamps to a pipe with a diameter of 20 to 50 mm (vertical or horizontal) and then attach the shield with the enclosed M8 nuts (see figure). The pipe should not interfere with the space next to the shield.
MEASURING PROBE INSTALLATION
- Insert the measuring probes into the glands at the bottom of the shield to the recommended height (see figure) and tighten the nut to secure the probe.
- Secure the cables with cable ties. Insert blanking plugs in unused glands.
TECHNICAL SPECIFICATION
- Diameter of the installed probe: 13 až 18 mm
- Fixing the shield: on a pipe with a diameter of 20 to 50 mm
- Temperature operating range: -40 až +65 ºC
- Relative humidity operating range: 0 až 100 %RH
- Storage temperature range: -40 až +65 °C
- Storage relative humidity range: 0 až 100 %RH (no condensation)
- Weight: approximately 2.4 kg (without mounting clamps)
- Material: UV stabilized ASA, stainless steel
CONTENT OF THE PACKAGE
- shield F8004: 1 pc
- mounting clamp: 2 pcs
- cable tie: 4 pcs
- nut M8: 4 pcs
- blanking plug: 2 pcs
END OF OPERATION
- The radiation shield dispose according to current legislation.
SUPPORT AND SERVICE
TECHNICAL SUPPORT AND SERVICE
- Technical support and service is provided by the distributor. For contact see warranty certificate.
WARNING
- Installation, commissioning and maintenance may only be carried out by personnel with qualification by applicable regulations and standards.
© Copyright: COMET SYSTEM, s.r.o.
It is prohibited to copy and make any changes in this manual, without explicit agreement of company COMET SYSTEM, Ltd. All rights reserved. COMET SYSTEM, Ltd. makes constant development and improvement of their products. Manufacturer reserves the right to make technical changes to the device without previous notice. Misprints reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>