CHICAGO FAUCETS HyTronic CFC01 User Guide
- October 30, 2023
- CHICAGO FAUCETS
Table of Contents
- CHICAGO FAUCETS HyTronic CFC01
- Product Information
- Product Usage Instructions
- CARE AND MAINTENANCE INSTRUCTIONS
- Cleaning or Replacing Inlet Filter
- Cleaning or Replacing Aerator
- Commander Handheld Programming Unit
- Faucet Adiustment Overview
- Care and Maintenance
- TROUBLESHOOTING
- CHICAGO FAUCETS LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CHICAGO FAUCETS HyTronic CFC01
Product Information
The product is a faucet with internal and external mixers that can be adjusted to control water temperature. The faucet also has a hot water limiter that can be adjusted to change the proportion of hot water. The product comes with an inlet filter and an aerator that can be cleaned or replaced periodically. Additionally, the product has a Commander Handheld Programming Unit that allows for adjustment of operating modes and sensor ranges.
Product Usage Instructions
Replacing Battery
-
Remove shut-off screw
-
Remove mixer handle (for faucets with external mixer only)
-
Remove housing vertically
-
Remove used battery from holder and recycle
-
Insert new battery. IMPORTANT: be sure battery is fully seated. LED will illuminate when battery is properly installed.
-
Mount housing vertically
-
Install shut-off screw
-
Install mixer handle (for faucets with external mixer only)
Adjusting Water Temperature (Internal Mix)
-
Remove shut-off screw
-
Remove housing vertically
-
Adjust internal mixer with screwdriver Clockwise > warm Counterclockwise < cold
-
Mount housing vertically
-
Install shut-off screw
Note: Carefully test the new temperature. If necessary, adjust again.
Adjusting Hot Water Limiter (External Mixer)
Note: Hot water may burn your skin. To avoid the risk of scalding, use
a thermometer to check water temperature.
-
Remove housing vertically
-
Carefully pull out hot water limiter from handle (using pliers) and reverse by 180° Settings of hot water limiter View from placement in mixer handle
-
Mount mixer handle The proportion of hot watt is now changed.
Cleaning or Replacing Inlet Filter
-
Close supply valves
-
Disconnect braided hoses and carefully remove filter that is pressed into hose. Clean or replace filter.
-
Connect braided hoses with filter to supply valves and open the valves
Cleaning or Replacing Aerator
-
Remove shut-off screw
-
Remove outlet with vandal resistant wrench supplied with the faucet. Clean or replace outlet, then reinstall.
-
Install shut-off screw
Commander Handheld Programming Unit
Note: Faucet adjustment operations apply to all models.
Operating modes and sensor ranges can be adjusted with the Chicago Faucets
CommanderTM Handheld Programming Unit. For more information, visit
chicagofaucets.com/commander.
Faucet Adjustment Overview
In order to set the operating modes, the faucet needs to be placed into
Manual Setting mode. At this time, operating modes can be changed within the
next 30 minutes.
The following operating modes are available:
- Cleaning Mode
- Normal Mode
- Metering Mode (10 s)
- Scrub Mode (60 s)
- Scrub Mode (180 s)
- Sensor Range Adjustment
- Reset
CARE AND MAINTENANCE INSTRUCTIONS
Replacing Battery
A traditional lavatory faucet is shown as an example. These instructions
apply to all DC and EBPS models. Prerequisites
- Battery is low (LED is lit)
- New 6 V Lithium battery (CR-P2) is required
- NOTE: For EBPS units, low battery LED will only light when AC power is disconnected
-
Remove shut-off screw
-
Remove mixer handle (for faucets with external mixer only)
-
Remove housing vertically
-
Remove used battery from holder and recycle
-
Insert new battery.
IMPORTANT: be sure battery is fully seated. LED will illuminate when battery is properly installed -
Mount housing vertically
-
Install shut-off screw
-
Install mixer handle (for faucets with external mixer only) The battery is now replaced
Adjusting Water Temperature (Internal Mix)
A traditional lavatory faucet is shown as an example. These instructions
apply to all models with internal mixers
- Remove shut-off screw
- Remove housing vertically
- Adjust internal mixer with screwdriver Clockwise > warm Counterclockwise < cold
- Mount housing vertically
- Install shut-off screw The temperature is now adjusted. Carefully test the new temperature. If necessary, adjust again.
Adjusting Hot Water Limiter (External Mixer)
A traditional lavatory faucet is shown as an example. These instructions apply
to all models with user adjustable temperature control. The proportion of hot
water can be switched from approximately 85% to 95% (or reverse) depending
upon inlet water pressures and temperatures. The default setting is 85%.
WARNING: Hot water may burn your skin. To avoid the risk of scalding, use a thermometer to check water temperature. Avoid contact with the water stream until the water temperature has been properly adjusted.
-
Remove mixer handle
-
Carefully pull out hot water limiter from handle (using pliers) and reverse by 180°
Settings of hot water limiter (View from placement in mixer handle -
Mount mixer handle The proportion of hot water is now changed.
Cleaning or Replacing Inlet Filter
- Close supply valves
- Disconnect braided hoses and carefully remove filter that is pressed into hose. Clean or replace filter.
- Connect braided hoses with filter to supply valves and open the valves. Cold water > white label Warm water > no label The filter is now cleaned or replaced.
Cleaning or Replacing Aerator
- Remove shut-off screw
- Remove outlet with vandal resistant wrench supplied with the faucet. Clean or replace outlet, then reinstall.
- Install shut-off screw The outlet is now cleaned or replaced.
Commander Handheld Programming Unit
Use the Commander™ Handheld Programming Unit to change settings quickly and easily on your Chicago Faucets HyTronic® and E-Tronic® products. The Commander* Handheld Programming Unit lets you program, maintain, and monitor our electronic faucets from the palm of your hand. Commander features a ruggedized housing, infrared communications, and touch-screen technology. Refer to the Commander Quick Start Guide to get started.
Faucet Adiustment Overview
Operating modes and sensor ranges can be adjusted with a manual operation through the infrared sensor. A traditional lavatory faucet is shown as an example. Faucet adjustment operations apply to all models. Alternatively, operating modes and sensor ranges can be adjusted with the Chicago Faucets Commander™ Handheld Programming Unit. For more information, visit chicagofaucets.com/commander.
Operating Modes :Description
- Cleaning Mode The faucet is inactive for 90 seconds.
- Normal Mode The faucet is activated if it senses a hand presence. This is the default operating mode of the faucet.
- Metering Mode (10 s) The faucet will shut off after 10 seconds regardless of hand presence detected.
- Scrub Mode (60 s) The faucet will shut off 60 seconds after the detection of the last hand presence.
- Scrub Mode (180 s) The faucet will shut off 180 seconds after the detection of the last hand presence.
- Sensor Range Adjustment Change the detection distance of the infrared sensor. The default sensor range is approximately 1˝ beyond the spout.
- Reset All settings will be reset to original factory settings.
In order to set the operating modes, the faucet needs to be placed into “Manual Setting” mode. At this time, operating modes can be changed within the next 30 minutes.
Care and Maintenance
All Chicago Faucets fittings are designed and engineered to meet or exceed
industry performance standards. Care should be taken when cleaning this
product. Do not use abrasive cleaners, chemicals or solvents as they can
result in surface damage. Use mild soap with warm water for cleaning and
protecting the surface of Chicago Faucets fittings.
For additional technical assistance, call 800/TEC-TRUE (800-832-8783) or visit
our website at chicagofaucets.com.
TROUBLESHOOTING
No Water Flow
Cause| Solution
Supply valves are closed| Open supply valves.
Aerator is blocked or dirty| Clean or replace outlet. See “Care and
Maintenance”.
Water line filter is dirty or blocked| Clean or replace filter. See “Care and
Maintenance”.
Braided hose is kinked| Eliminate braided hose kink.
No external water pressure| Check water pressure. Provide water pressure.
Battery is drained| Replace SSPS unit. Contact Chicago Faucets technical
service or replace power adapter
Reverse green adapter insertion| Insert green adapter correctly.
Connector between SSPS and power adapter unplugged| Plug connector. (green
plugs)
Corroded power adapter contacts| Clean contacts.
Connecting cable is kinked or broken| Replace defective parts. See
“Replacement Parts”at chicagofaucets.com
Shut-off screw is missing or defective| Replace shut-off screw or defective
See “Replacement Parts” at chicagofaucets.com
Solenoid valve inoperable| Replace solenoid valve. See “Replacement Parts” at
chicagofaucets.com.
Faucet is in cleaning mode| Wait for cleaning mode to end (appr. 90 seconds)
Electronics module inoperable| Contact technical service or replace power
adapter See “Replacement Parts”at
chicagofaucets.com
Green Power adapter defective| Contact technical service or replace power
adapter See “Replacement Parts”at
chicagofaucets.com
Sensor distance is not adjusted properly| Remove and re-install shut-off
screw. Do not disturb scanning procedure until water stops and LED is off.
Infrared window scratched or dirty| Clean window with smooth cloth
Interfering reflections from sink| Remove and re-install shut-off screw. Do
not disturb scanning procedure until water stops and LED is off. Adjust upper
and lower beam to compensate for reflections. (Commander™ Handheld Unit
required. Go to www.chicagofaucets.com/commander
for details)
Water Runs Continuously and Stops When Object Present
Cause| Solution
Connector between electronics module and solenoid valve plug is reversed| Plug
connector properly
Water Flows Although Shut-Off Screw Is Removed
Cause| Solution
Electronics module inoperable| Contact technical service or replace power
adapter See “Replacement Parts”at
chicagofaucets.com
Water drops on infrared window| Clean window with smooth cloth
Water Runs Continuously
Cause| Solution
Interfering object is in monitoring range| Remove object from monitoring area.
Remove and re-install shut-off screw. Do not disturb scanning procedure until
water stops and LED is off.
Defective electronics module| Replace electronics module. See “Replacement
Parts” at chicagofaucets.com
Improper electronics module| Change mode or reset sensor. See “Care and
Maintenance”.
External water pressure is too high| Check external water pressure. Provide
pressure between 20 – 125 psi.
Solenoid valve inoperable| Replace solenoid valve. See “Replacement Parts” at
chicagofaucets.com.
Faucet Turns On By Itself
Cause| Solution
Infrared window scratched or dirty| Clean window with smooth cloth
Faucet is influenced by room environment (mirror, stainless steel or glass
sink, etc.)| Remove and re-install shut-off screw. Do not disturb scanning
procedure until water stops and LED is off. Adjust upper and lower beam to
compensate for reflections. (Commander™ Handheld Unit required. Go to
www.chicagofaucets.com/commander
for details)
Input line pressure fluctuates| Install appropriate line pressure regulators
Faucet Is Leaking Water
Cause| Solution
Connections between housing and braided hose| Check O-rings. Replace damaged
or missing O-rings.
Connection between braided hose and inlet supply are loose| Check rubber
washers. Replace washers when damaged or missing.
Connection between valve body and solenoid valve is loose| Check O-rings.
Replace damaged O-rings. Carefully re- install solenoid valve & do not over
tighten.
Faucet drips, solenoid valve does not close| Clean or replace solenoid valve.
See “Replacement Parts” at chicagofaucets.com.
Temperature Cannot Be Adjusted Properly
Cause| Solution
Supply valves not fully opened.| Fully open supply valves.
Water line filter is dirty or blocked| Clean or replace filter. See “Care and
Maintenance”.
Braided hose is kinked| Eliminate braided hose kink.
Backflow preventer in faucet is blocked| Unblock backflow preventer
Temperature of hot or cold supply is too low| Check inlet temperature or
inspect boiler.
Hot water temperature not sufficient| Reverse hot water limiter. See “Care and
Maintenance”
Inlet hoses are reversed| Correct the connections.
CHICAGO FAUCETS LIMITED WARRANTY
- TO WHOM DOES THIS WARRANTY APPLY? — The Company extends the following limited warranty to the original user only.
WHAT DOES THIS WARRANTY COVER AND HOW LONG DOES IT LAST?
This warranty covers the following Commercial Products:
-
LIFETIME FAUCET WARRANTY — The “Faucet,” defined as any metal cast, forged, stamped or formed portion of the Product, not including electronic or moving parts or other
-
products separately covered by this Limited Warranty or water restricting components or other components, is warranted against material manufacturing defects for the life of the Product.
-
FIVE YEAR FAUCET WARRANTY — Certain Products and portions of the Product are warranted against material manufacturing defects for a period of five (5) years from the date of Product purchase. Products warranted against material manufacturing defects for a period of five (5) years from the date of Product purchase are referred to by the product numbers 42X, 43X, 15XX and E-Tronic™ – 4X, 5X, 6X, 7X, 8X and 9X. All zinc die cast portions of Product are warranted against material manufacturing defects for a period of five (5) years from the date of Product purchase.
-
THREE YEAR ELECTRONICS WARRANTY — Electronic components, including the solenoid, are warranted for three (3) years from the date of installation.
-
FIVE YEAR CARTRIDGE WARRANTY — The “Cartridge”, defined as the metal portion of any Product typically referred to
by the product numbers containing 1-099, 1-100, 377X, 217X and 274X, excluding any rubber or plastic components,
is warranted against material manufacturing defects for a period of five (5) years from the date of Product purchase.
All Cartridges included in the Company’s Single Control or Shower Products also are warranted against material manufacturing defects for a period of five (5) years from the date of Product purchase. -
ONE YEAR FINISH WARRANTY – COMMERCIAL — For Products used in commercial applications, the finish of the
Product is warranted against material manufacturing defects for a period of one (1) year from the date of Product purchase. -
OTHER WARRANTIES — All other Products not covered above are warranted against material manufacturing defects for a period of one (1) year from the date of Product purchase. Other restrictions and limitations apply. For complete warranty details, call Chicago Faucets Customer Service at 847-803-5000 or visit chicagofaucets.com.
The Chicago Faucet Company 2100 South Clearwater Drive Des Plaines, IL 60018
Phone: 847/803-5000
Fax: 847/803-5454 Technical: 800/832-8783
www.chicagofaucets.com
© 2022 The Chicago Faucet Company
964.893.00.0
References
- Home | Chicago Faucets
- Commander™ Handheld Programming Unit | Chicago Faucets
- Home | Chicago Faucets
- Commander™ Handheld Programming Unit | Chicago Faucets
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>