INSTALL INSTRUCTIONS
PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION. Please read the
instructions before you install the sensor and use the luminaire.
GENERAL: ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL AND
NATIONAL ELECTRICAL CODES (N.E.C.) STANDARDS. IF YOU ARE
UNFAMILIAR WITH PROPER ELECTRICAL WIRING CONNECTIONS OBTAIN THE SERVICES OF A
QUALIFIED ELECTRICIAN. REMOVE FROM THE BOX AND MAKE SURE THAT NO PARTS ARE
MISSING.
WARNING – Risk of fire or electric shock. Sensor installation requires
knowledge of luminaire electrical systems. If not qualified, do not attempt
installation.
Contact a qualified electrician.
WARNING – Risk of fire or electric shock. Install this sensor only in
luminaires that have the construction features and dimensions shown in the
photographs
and/or drawings and where the input rating of the sensor does not exceed the
input rating of the luminaire.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to
the edges of sheet metal or other sharp objects. Risk of Electric Shock:
Disconnect power or circuit breaker before installing or servicing. Do not
make or alter any open holes in an enclosure of wiring or electrical
components during installation.
WARNING
NOTE: Warm-up time is 40 seconds. After the sensor connects to input
power for the first time, the light will stay on for 40 seconds, then operate
per sensor settings.
NOTE: Once powering up the device, the sensor will use the factory
default settings to operate. Factory Default Settings: Sensitivity set to
100%. Hold on time 5 min. Daylight sensor at. Dimming level at 30%. Dimming
time at 60 minutes.
NOTE: RC-100 remote (sold separately) required to make adjustments to any
sensor settings. The LED light will turn on/off as confirmation of the change.
WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.
SENSOR SPECIFICATIONS
Power Supply| 100-347V – Single Phase – 60Hz
208/230/480V – Phase-to-Phase – 60Hz
---|---
Maximum Load| 100-120V – 800W Tungsten
100-120V – 800W Electronic Ballast/ LED Driver
230-240V – 300W Electronic Ballast/ LED Driver
277V -1200W Electronic Ballast/ LED Driver
347V -1200W Electronic Ballast/ LED Driver
480V – 480W Electronic Ballast/ LED Driver
HF System| 5,8GHz CW
Dim Control Output| 0-10VDC 50mA
Detection Radius| Max, 26ft / 8 Meters – 360°
Mounting Height| Max 40ft /12 Meters
Remote Range (optional)| 50ft / 15 Meters Indoor, No Backlight
Time Setting| 10 sec, – 60 min. (Adjustable)
Light Control| 10-500 LUX (Adjustable)
Temperature| -40° ∼ 158°F (-40° ∼70°C)
WIRING DIAGRAM
SENSOR COVERAGE
PREMIUM QUALITY LIGHTING®
• www.PQLighting.com
© P.Q.L., Inc. • 2285 Ward Avenue
• Simi Valley, CA 93065 • 800-323-8107
Specifications subject to change without notice. Photos and line drawings may
not be to scale and are for general reference only.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>