AUDiONET AMP 1 V2 Stereo Amplifier User Manual

June 10, 2024
AUDiONET

AUDiONET AMP 1 V2 Stereo Amplifier

AUDiONET-AMP-1-V2-Stereo-Amplifier-PRODUCT-IMG

Product Information

The Audionet AMP1 V2 is a high-performance stereo audio power amplifier that provides natural music reproduction. It is built with high-quality materials to ensure long-term stability and durability. This user manual provides all the necessary information to operate the AMP1 V2 and ensure long-lasting pleasure and satisfaction.

Preface

The Audionet AMP1 V2 is a stereo audio power amplifier of the highest performance and finish quality and long-life stability. This system is designed for absolute natural music reproduction. The following will give you all information about how to operate your AMP1 V2. Please read this carefully before the first use. Following these instructions, your AMP1 V2 will give you long-lasting pleasure and satisfaction.

Included

Included you will find the following items:

  • the stereo power amplifier AMP1 V2
  • the user’s manual (that you are currently reading)
  • one standard mains cord

Transport

Important

  • Please transport the AMP1 V2 only in the included package.
  • Always use the provided bag to prevent scratches on the housing.
  • Please allow the AMP1 V2 to adapt to the climatic conditions in your listening room before you switch on the unit for the first time after transport.

Overview control elements

Front panel

AUDiONET-AMP-1-V2-Stereo-Amplifier-FIG-1

Overview connections

Back panel

AUDiONET-AMP-1-V2-Stereo-Amplifier-FIG-2

  1. Line (RCA) input right
  2. Speaker terminal right
  3. Audionet Link input
  4. Audionet Link output
  5. Mains input
  6. Marking Mains phase
  7. Speaker terminal left
  8. Line (RCA) input left

Installation and power supply

Important

  • For connecting or removing loudspeakers and/or the preamplifier your AMP1 V2 must be switched off to prevent damage to the amplifier or the connected units.
  • Please make sure that all cables are in the absolute best condition! Broken shields or short-cut loudspeaker cables could damage speakers and/or amplifiers.

Placement
The compact design of the AMP1 V2 requires unobstructed heat dissipation during operation. Please mind the following security notes:

Important

  • Please find a place for your Audionet AMP1 V2 that is sufficiently ventilated to allow the heat to dissipate.
  • Do not expose the unit to direct sunlight or in close range to heat sources like radiators or fan heaters.
  • Do not cover the ventilation slots of the unit.

Mains connection

The mains input 5 * is on the back panel of the AMP1 V2. To connect the unit to mains use the included cord. If you prefer to use a different power cord make sure they meet the specifications for your home country.

Important

  • The electrical specifications of your home country must meet the electrical specifications printed on the back panel.
  • The AMP1 V2 is a Class I unit and must be earthed. Please ensure an astable earth connection. The Phase (‘hot’ pin) is marked ‘PHASE’ 6 on the back panel for the mains input.
  • Never pull the mains plug while the AMP1 V2 is switched on! Before you pull the mains cord off the socket, power down the unit to standby mode.
  • Only in cases of extended absence (like vacations) or if massive trouble on the mains power is to be expected you should remove the AMP1 V2 from the mains. To disconnect the unit completely from mains pull both mains plugs.

Note

  • Using high-quality main cords like the Audionet P10 may improve sound quality. Please consult your local Audionet dealer.

Inputs and outputs

Important

  • For connecting or removing loudspeakers and/or the pre-amplifier your AMP1 V2 must be switched off to prevent damage to the amplifier or the connected units.
  • Please make sure that all cables are in the absolute best condition! Broken shields or short-cut loudspeaker cables could damage speakers and/or amplifiers.

Inputs

  • The AMP1 V2 has two RCA inputs 1 and 8 for the connection of a pre-amplifier, e.g. Audionet PRE G2. Due to the dual mono construction, left and right inputs are separated at the rear.
  • Please connect the right 1 and left input 8 of the AMP1 V2 to the corresponding outputs of your pre-amplifier.

Speaker terminals

Connect your speakers to the gold-plated terminals 2 and 7 on the back panel of the AMP1 V2. You can use banana plugs or spades as well as simple cable ends. In case you would like to bi-wire your speakers please refer to the section ‘Bi-Wiring’ on page 11.

Note

  • Look out for the correct connection of your speaker cables. Usually, the terminals of your speakers are marked ‘+’ and ‘-‘. The AMP uses the same marks.
  • Wrong speaker polarization will result in a severe loss of sound quality!

Important

  • Although the AMP1 V2 has an effective protection system to prevent damage to the circuits, switch off the unit while working on the speaker and/or audio cables.

Note

  • The nominal loudspeaker impedance should be 2 Ohms or higher.
  • Never use force or tools to tighten the terminal screws.

Bi-Wiring
If your speakers support bi-wiring, use two separate cables to connect each speaker to the output terminals 2 and 7 of the AMP1 V2. Impulse response and spatiality may improve significantly.

Note

  • Again, please mind the correct polarization of the speakers!

Bridged operation
A second AMP1 V2 bridged operation is possible (please refer to technical information). In this case, every amplifier supplies only one loudspeaker. For that, the output signal of the pre-amplifier must be available in inverted form additionally (e.g. use the Audionet PRE G2). For the left channel now please do the following: Connect the normal signal of the left pre-amplifier output to the left input 1 and the inverted signal to the right input 8 of the AMP I V2 supplying the left loudspeaker. Please make a solid connection (wire cross-section of 4.0 mm²) between both (–) loudspeaker outputs. Now please connect the left loudspeaker to both remaining (+)-outputs (the positive input of the loudspeaker to the (+) output of the left channel). For connecting the right channel please do the corresponding with the second amplifier.

Important

  • In bridged operation, the loudspeaker impedance must be 4 ohms or more.

Audionet Link
For your convenience, the AMP1 V2 can be controlled remotely by one of Audionet’s multi-channel pre amplifiers (e.g. MAP or MAP 1) as well as one of Audionet’s stereo pre amplifiers (e.g. PRE G2, PRE 1 G3) using the Audionet Link interface. You only need an optical ‘Toslink’ cable to connect the Audionet Link output of your Audionet pre-amplifier to the Audionet Link input IN 3 of the AMP1 V2. In case you would like to automatically switch on/off further Audionet units in your system (e.g. a second AMP1 V2) using the Audionet Link interface, please connect the Audionet Link output OUT 4 of your AMP1 V2 to the Audionet Link input of the next Audionet unit (e.g. power amplifier, tuner, CD player, etc.) using a simple ‘Toslink’ cable.

Note

The ‘switch on’ signal is issued to any further Audionet units daisy chained to the Audionet Link output of your AMP1 V2 with a little delay to avoid all units switching on at the same moment, which could cause an overload of your mains fuse.

Operating

Powering up
First of all, please make sure your AMP1 V2 is connected correctly to your pre-amplifier, speakers and mains (see section ‘Installation and power supply’ on page 8 and section ‘Inputs and outputs’ on page 10). The AMP1 V2 is a standby unit. As soon as the amplifier is connected to the mains, the unit is in stand-by mode Only in cases of extended absence (like vacations) or if massive trouble on the mains power is to be expected it is recommended to disconnect the AMP1 V2 from mains.

Important

Never pull the mains cord while the AMP1 V2 is switched on! Before you pull the mains plug, power down the unit to standby mode first.

Switching on/off
To power up the AMP1 V2 from standby mode, press the power key on the front panel. Now the AMP1 V2 is in normal operating mode. If you would like to switch off the unit, please press the power key on the front panel.

Note

If ‘remote controlling’ via Audionet-link is used, after switching off the AMP1 V2 is always in stand-by operation with low power consumption. Only in case of longer absence, the AMP1 V2 should be disconnected from the power supply (mains unplugged).

Using Audionet Link
If your AMP1 V2 is connected to an Audionet pre-amplifier via Audionet Link, use the remote control of the pre-amplifier to automatically switch on/off the AMP1 V2 (and all other Audionet units also connected via Audionet Link). For setting up the necessary connections please refer to section ‘Audionet Link’ on page 12.

Protection system

Your AMP1 V2 has a powerful protection circuit to prevent damage of the amplifier itself or the loudspeakers connected. In case of trouble, the AMP1 V2 is switched to stand-by state. The source of the problem is indicated by a flash code of the LED next to the power key on the front panel:

Error Code Possible Cause
short short short overload – left channel
short short long overload – right channel
short long short overheat – left channel
short long long overheat – right channel
long short short high-frequency oscillation – left channel
long short long high-frequency oscillation – right channel
long long short direct current (DC) – left channel
long long long direct current (DC) – right channel

Technical information

Construction
The AMP1 V2 is constructed as a dual-mono amplifier. SMD techniques are used to optimize high-frequency characteristics. All signal paths are reduced to a minimum length. No elements malicious to sound quality (i.e. coupling capacitors, coils, relays) are located in the signal path. The construction is magnetically and capacitively optimized. Negative magnetic and electric influence and interaction between input, decoupling, and power section are reduced to a residual minimum.

Power supply

The input sections are supplied by a 50 VA toroidal transformer with separate windings for stereo channels. Two potted 700 VA toroidal transformers feed the power section. The control unit is supplied by a separate transformer. The capacity of the fast and pulse-resistant high-current capacitors is 188,000 mF. The voltages are regulated with discrete and optimized ultra-high-speed MOSFET regulators.

Security advice

  • Avoid packaging material, especially plastic bags, to come into children’s hands.
  • Store and operate the unit in a dry room at a reasonable room temperature.
  • Avoid moisture or any liquid getting into the unit.
  • Set up the unit in a free position so that the air is allowed to flow through the unit slits.
  • Do not cover, e.g. with a blanket.
  • Do not open the case. The unauthorized opening will cause a loss of guarantee.
  • Use a dry cloth for cleaning.

Technical data

Function Stereo power amplifier
Output Power 2 * 200 Watt into 8 Ohm

2 * 300 Watt into 4 Ohm

2 * 450 Watt into 2 Ohm

1 * 600 Watt into 8 Ohm (bridged)

1 * 900 Watt into 4 Ohm (bridged))

Frequency range| 0 – 300.000 Hz (-3dB)
Damping factor| > 1000 @10 kHz

4000 @ 500 Hz

Intermodulation| < -110 dB SMPTE 100 Hz : 20 kHz, 4:1, 50 W/4 Ohm
THD+N| < -102 dB @1 kHz (35 Watt / 2 Ohm)
Harmonic distortion| k2 typ. –120 dB @ 25 Watt into 4 Ohm k3 typ. –123 dB @ 25 Watt into 4 Ohm
SNR| > 106 dB @ 10 Veff
Inputs| 2 Furutech RCA line, gold-plated 1 Audionet Link, optical
Input impedance| 37 kOhm, 220 pF


Outputs

| 2 pair Furutech jacks, Rhodium

1 Audionet Link, optical (Toslink)

Mains| 220..240 V or 110..120 V, 50..60 Hz
Power consumption| Stand-by < 1W, max. 1.500 W


Dimensions

| Width:                  430 mm

Height:                175 mm

Depth:                 315 mm

Weight| 28 kg
Finish| Front : brushed aluminum, 10 mm black anodized, white printing or nature anodized, black printing

Display : red or blue

Cover and heat sink : aluminum black anodized

Chassis : steel, black varnished, 2 mm

Features| –          Audionet ULA technology

–          dual-mono amplifier

–          magnetically and capacitively optimized construction

–          signal paths are kept to a minimum

–          no capacitors and electromechanical components in the signal path

–          completely DC coupled

–          separate power supply for input and power stage

–          2 toroid transformers, each with 700 VA

–          4 impulse-stable high-current capacitors with filtering capacity totaling 188,000 uF

–          discrete, extremely fast, and stable driver and output stages

–          control unit for HF, DC, temperature rise, and overload

–          remote activation via Audionet Link (fiber optics cable)

---|---

audience GmbH

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals