DRAZICE NADO 500-200 v7 Storage Tank User Manual
- June 10, 2024
- Drazice
Table of Contents
- NADO 500-200 v7 Storage Tank
- FUNCTION DESCRIPTION
- THE DESIGN OF SUITABLE VOLUME AND TANK INSTALLATION
- TECHNICAL PARAMETERS
- IMPORTANT WARNING
- TECHNICAL DESCRIPTION
- DIMENSIONS AND CONNECTION
- DISPOSAL OF PACKAGING MATERIAL AND NON-FUNCTIONING PRODUCT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
STORAGE TANKS
NADO 500/200 v7
NADO 750/200 v7
NADO 1000/200 v7
OPERATING AND
INSTALLATION MANUAL
NADO 500-200 v7 Storage Tank
CAREFULLY READ THIS MANUAL BEFORE INSTALLING THE TANK!
Dear Customer,
Družstevní závody Dražice – strojírna s.r.o., would like to thank you for your
decision to use a product of our brand.
The product is not intended to be controlled by
a) people (including children) with reduced physical, sensual or mental
capacities, or
b) people with insufficient knowledge and experiences unless supervised by a
responsible person, or unless properly instructed by such responsible person.
The manufacturer reserves the right for engineering modification of the
product.
It is recommended to use the product in an indoor environment with air
temperatures from +2 °C to +45 °C and a relative humidity up to 80 %.
Product’s reliability and safety is proven by tests implemented by the
Engineering Test Institute in Brno.
Made in the Czech Republic.
Meaning of pictograms used in the Manual
Important information for heater users.
Abiding by the recommendations of the manufacturer serves to ensure trouble-
free operation and the long service life of the product.
Caution!
Important notice to be observed.
FUNCTION DESCRIPTION
Storage tanks serve the accumulation of excessive heat from their source. The
source may be a solid fuel boiler, heat pump, solar collector, fireplace
inserts, etc. Some types of storage tanks allow the combination of connecting
even multiple sources.
The NADO-type storage tanks serve the accumulation of heat in the heating
system and allow heating or preheating of HSW (Hot Service Water) in an inner
vessel. The incorporation of a storage tank in the heating system with a solid
fuel boiler allows an ideal run of a boiler at a favourable temperature during
the boiler operation. The main benefit lies in the period of optimum operation
(i.e., with maximum efficiency) when the excessive unconsumed heat accumulates
in the storage tank.
The tanks and tubular exchangers are made of steel, without the inner surface
treatment, the outer surface of the tank is provided with a protective paint.
The storage tanks are manufactured in 500, 750 and 1000-litre volumes. The
500-litre version is additionally equipped with a tubular exchanger of 2.5 m
surface and the 750 and 1000 litre versions with a tubular exchanger of 3.3 m2
surface and two funnels G1½“ mm, with the possibility to install an electric
heating element of TJ 6/4“ series with an extended cooling compartment, up to
6 kW. The storage tanks are equipped with removable 80 mm thick insulation and
a lock.
The NADO type enables direct heating of HSW (Hot Service Water) in an inner
enamelled tank or preheating of water for another water heater. Connection to
a boiler usually allows direct HSW heating in an inner vessel to the desired
temperature whilst, on the contrary, connection to solar collectors or heat
pump only preheats HSW and another, e.g. electric, heater has to be used, in
order to reheat the water to the desired temperature, or final electric reheat
has to be fitted in the storage tank which is enabled by a TJ 6/4“ series
electric heating unit with an extended compartment of up to 6 kW output.
THE DESIGN OF SUITABLE VOLUME AND TANK INSTALLATION
An ideal size of the storage tank is designed by a design engineer, or a
person sufficiently qualified to design heating systems.
Product assembly must be implemented by an authorized person (confirmed in the
warranty certificate).
When putting into operation, water has to be filled first into the inner tank
for HSW and the operating pressure inside it has to be kept, only then heating
water can be filled into the outer storage tank, otherwise the product may get
damaged!
The manufacturer explicitly emphasizes the necessity of being particular in
testing the tightness of the heating circuit (radiators, piping joints, floor
heating, etc.) with the connection of the storage tank. No pressure growth in
the storage tank heating water compartment may occur above the maximum
operating pressure of 0.3 MPa, if the heating system is pressurized to higher
than the maximum operating pressure, the inner enamelled tank may get
permanently damaged!
TECHNICAL PARAMETERS
| | NADO 500/200 v7| NADO 750/200 v7| NADO 1000/200 v7
---|---|---|---|---
STORAGE TANK CAPACITY| l| 475| 772| 999
VOLUME OF STORAGE TANK FOR HW HEATING| l| 233| 233| 233
WEIGHT| kg| 175| 212| 243
TANK DIAMETER| mm| 600| 790| 790
TANK DIAMETEK WITH INSULATION| mm| 800| 990| 990
HEAT TRANSFER SURFACE OF HEAT EXCHANGER| m2| 2.5| 3.3| 3.3
MAXIMUM TANK PRESSURE| bar| 3| 3| 3
MAX. PRESSURE IN EXCHANGER TV| bar| 6| 6| 6
MAX. PRESSURE IN HEAT EXCHANGER| bar| 10| 10| 10
MAXIMUM TEMPERATURE OF WATER IN THE TANK| °C| 90| 90| 90
MAXIMUM TEMPERATURE OF WATER IN THE EXCHANGER| °C| 90| 90| 90
MAXIMUM WORKING TEMPERATURE IN THE HEAT EXCHANGER| °C| 110| 110| 110
AMOUNT OF 40°C HOT WATER AT 53°C WATER TEMPERATURE IN THE TANK AND INLET WATER
15°C/ HOT WATER FLOW| l/(l/min)| 260 / 10| 490 / 10| 750 / 10
AMOUNT OF 40°C HOT WATER AT 80°C WATER TEMPERATURE IN THE TANK AND INLET WATER
15 °C
/ HOT WATER FLOW| l/(l/min)| 650 / 10| 1170 / 10| 1450 / 10
MAXIMUM OUTPUT OF EL.
HEATING ELEMENT OF TJ 6/4″ SERIES| kW| –| 2×6| 2×6
ENERGY EFFICIENCY CLASS| | B| C| C
STANDING LOSS| W| 76| 113| 126
IMPORTANT WARNING
Connection of the inner tank to HSW must comply with ČSN 06 0830, a safety valve has to be fitted on the cold water inlet.
It is necessary to activate the heating circuit and remove potential
impurities that are captured in the filter; after that, the system is fully
functional.
The appliance has to be mounted at a convenient place, it means that the
appliance must be easily available for potential necessary maintenance, repair
or replacement, as the case may be.
No stop fitting can be put between the secure fitting of the heating circuit
and the storage tank!!!
Recommended operating pressure of the hot water circle is 0.4 MPa.
We recommend checking and cleaning the inner vessel from scale and eventual
replacement of the anode rod after two years of operation. The anode life is
theoretically calculated for two years of operation; however, it changes with
water hardness and chemical composition in the place of use.
Prior to commissioning, we recommend that you run the heating circuit and any
impurities that are trapped in the filter clean, and then the system is fully
operational.
Shut down the reservoir cold water intake if you are not using the reservoir
for longer than 24 hours or if the object with the heater is without the
presence of any person.
TECHNICAL DESCRIPTION
- Heating water outlet G1″
- Hot water outlet G3/4″
- Cold water inlet G3,4″
- Funnel for additional heating element TJ 6/4″ with an extended cooling compartment 2x
- Thermowell funnel 6x G1/2″ – for 750l and 1000l only
- Funnel for connecting another heating water source 6x G1″
- The inlet into exchanger G1″ (SOLAR)
- The outlet from exchanger G1″ (SOLAR)
- Funnel for discharge G1″
- Steel receptacle
- Exchanger for connecting solar collectors (heat pump)
- Inner enamelled accumulator for service water heating
DIMENSIONS AND CONNECTION
NADO 500/200 v7
Funnels 6/4″ are fitted only with NADO 750, 1000/200 v7, for the electric
heating element of TJ 6/4″ series with an extended cooling compartment!
A | B | C | d | E | F | H | I | J | K | L | Lk | M | P | R |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
146 | 249 | 574 | 600 | 901 | 1226 | 1835 | 1679 | 477 | 690 | 1982 | 2002 | 1099 | 239 |
1019
Table 2
- G 1″ inner
- G 1/2″ inner
- G 1″ outer
- G 3/4″ outer
NADO 750/200 v7, NADO 1000/200 v7
- G 1″ inner
- G 1/2″ inner
- G 1″ outer
- G 3/4″ outer
- G 1 1/2″ inner
| NADO 750/200 v7| NADO 1000/200 v7
---|---|---
A| 157| 159
B| 259| 261
C| 585| 587
D| 790| 790
E| 911| 913
F| 1237| 1239
G| –| 1565
H| 1815| 2115
I| 1609| 1911
J| 469| 471
K| 689| 691
L| 1954| 2242
Lk| 1994| 2310
M| 1109| 1111
N| –| 1411
O| 1609| 1901
P| 249| 251
R| 909| 911
S| 1074| 1076
T| 275| 275
Table 3
DISPOSAL OF PACKAGING MATERIAL AND NON-FUNCTIONING PRODUCT
A service fee for providing return and recovery of packaging material has been paid for the packaging in which the product was delivered. The service fee was paid pursuant to Act No 477/2001 Coll., as amended, at EKO-KOM a.s. The client number of the company is F06020274. Take the water tank packages to a waste disposal place determined by the municipality. When the operation terminates, disassemble and transport the discarded and unserviceable heater to a waste recycling centre (collecting yard), or contact the manufacturer.
14-2-2022
www.dzd.cz
Read User Manual Online (PDF format)