- Once you connect the AC adaptor to the DC IN jack, the CHARGE indicator blinks three times and charging begins.
- The battery is in charging-only mode while the DC IN jack is plugged in. During this time, you can’t use the amp.
(1) Compatible amps: CUBE Street EX, AC-33, KC-220, BA-330
(2) For the BA-330, use the PSB-12U or PSB-12U2 (sold separately).
CHARGE Indicator | FAIL Indicator | Status | Action |
---|---|---|---|
Lit | Unlit | Charged | The CHARGE indicator turns off approximately 10 minutes |
after charging is completed.
Blinking slowly| Charged to 30% or
greater| Now charging. Allow the battery to keep charging.
Blink| Charged to about less than 30%
Unlit| Blink| Battery voltage is excessively low| •The battery’s voltage may
decrease right after it is used. Remove the BTY-NIMH/A from the amp, and try
charging it again several hours later.
•Try unplugging and plugging the adaptor into the DC IN jack several times.
Once the voltage reaches a level where charging is possible, the FAIL
indicator turns off, the CHARGE indicator blinks and you can keep charging.
- If an AC adaptor is plugged into the DC IN jack but the CHARGE and FAIL indicators remain unlit regardless of the above, either the battery has over-discharged or else the battery is malfunctioning. Contact your dealer or a Roland customer service center.
NOTE
-
Temperature range
during use: 0–40°C
when charge: 5–30°C (3)
when storage: 10–35°C
(3) In order to take full advantage of the battery’s performance, we recommend that you charge it in a temperature range of 5°C–30°C. -
You can charge the battery whenever you feel it’s necessary. We recommend that you charge the battery at least once a week.
-
In the event that you leave the amp on after use and the battery keeps discharging, the battery may over-discharge, causing the safety protection circuit to activate. The battery cannot recharge in this case.
Turn off the amp while not in use, and remove the BTY-NIMH/A from the amp. -
Sounds may distort easily or cut off when played at high volume as the battery power is nearly depleted, but this is not a malfunction. Charge the battery as soon as possible.
-
If you handle batteries improperly, you risk explosion and fiuid leakage. Make sure that you carefully observe all of the items related to batteries that are listed in “USING THE UNIT SAFELY” and “IMPORTANT NOTES”.
Attaching the Battery
Use the screws included with this battery to mount it onto the amp.
Main Specifications
Input voltage | DC 13 V |
---|---|
Output voltage | DC 9.6 V |
Capacity | 4,000 mAh |
Battery charging time | Approx. 4 hours |
Expected battery life
under continuous use| Approx. 20 hours
-
Depends on the amp used and conditions of use.
Dimensions| 184 (W) x 68 (D) x 41 (H) mm
7-1/4 (W) x 2-11/16 (D) x 1-5/8 (H) inches
Weight| 690 g / 1 lb 9 oz
Accessories| Owner’s Manual -
This document explains the specifications of the product at the time that the document was issued. For the latest information, refer to the Roland website.
USING THE UNIT SAFELY
INSTRUCTIONS FOR THE PREVENTION OF FIRE, ELECTRIC SHOCK, OR INJURY TO OERSONS
About WARNING and CAUTION Notices
WARNING| Used for instructions intended to alert the user to the risk of
death or severe injury should the unit be used improperly.
---|---
WARNING| Used for instructions intended to alert the user to the risk of
injury or material damage should the unit be used improperly.
- Material damage refers to damage or other adverse effects caused with respect to the home and all its furnishings, as well to domestic animals or pets.
About the Symbols
| The symbol alerts the user to important instructions or warnings.The
specific meaning of the symbol is determined by the design contained within
the triangle. In the case of the symbol at left, it is used for general
cautions, warnings, or alerts to danger.
---|---
| The symbol alerts the user to items that must never be carried out (are
forbidden). The specific thing that must not be done is indicated by the
design contained within the circle. In the case of the symbol at left, it
means that the unit must never be disassembled.
| The symbol alerts the user to things that must be carried out. The specific
thing that must be done is indicated by the design contained within the
circle. In the case of the symbol at left, it means that the power-cord plug
must be unplugged from the outlet.
ALWAYS OBSERVE THE FOLLOWING
WARNING
Do not disassemble or modify by yourself
Do not carry out anything unless you are instructed to do so in the owner’s
manual. Otherwise, you risk causing malfunction.
Do not repair or replace parts by yourself
Be sure to contact your dealer, a Roland service center, or an off cial Roland
dealer.
For a list of Roland service centers and off cial Roland dealers, refer to the
Roland website.
Do not use or store in the following types of locations
- Subject to temperature extremes (e.g., direct sunlight in an enclosed vehicle, near a heating duct, on top of heat-generating equipment); or are
- Damp (e.g., baths, washrooms, on wet floors); or are
- Exposed to steam or smoke; or are
- Subject to salt exposure; or are
- Exposed to rain; or are
- Dusty or sandy; or are
- Subject to high levels of vibration and shakiness; or are
- Placed in a poorly ventilated location
Use only the specified AC adaptor and the correct voltage
Use only the specified AC adaptor, and make sure the line voltage at the
installation matches the input voltage specified on the AC adaptor’s body.
Do not allow foreign objects or liquids to enter unit; never place containers
with liquid on unit
Do not place containers containing liquid (e.g., flower vases) on this
product. Never allow foreign objects (e.g., flammable objects, coins, wires)
or liquids (e.g., water or juice) to enter this product. Doing so may cause
short circuits, faulty operation, or other malfunctions.
Turn off the unit if an abnormality or malfunction occurs
In the following cases, immediately turn off the power, remove the AC adaptor
from the outlet, and contact your dealer, a Roland service center, or an off
cial Roland dealer for service.
- The AC adaptor or the power cord has been damaged; or
- If smoke or unusual odor occurs; or
- Objects have fallen into, or liquid has been spilled onto the unit; or
- The unit has been exposed to rain (or otherwise has become wet); or
- The unit does not appear to operate normally or exhibits a marked change in performance.
For a list of Roland service centers and off cial
Roland dealers, refer to the Roland website.
WARNING
Be cautious to protect children from injury
Always make sure that an adult is on hand to provide supervision and guidance
when using the unit in places where children are present, or when a child will
be using the unit.
Do not drop or subject to strong impact
Otherwise, you risk causing damage or malfunction.
Handle batteries carefully
If used improperly, you risk the dangers of fluid leakage, overheating,
combustion, explosion, etc. Carefully observe the following:
- Do not heat, disassemble, or toss them into a fire or water.
- Do not expose them to sunlight, flame, or any other source of extreme heat.
CAUTION
Disconnect the power plug whenever the unit will not be used for an extended
period of time
Fire may result in the unlikely event that a breakdown occurs.
Avoid climbing on top of the unit, or placing heavy objects on it
Otherwise, you risk injury as the result of the unit toppling over or dropping
down.
Before cleaning the unit, disconnect the power plug from the outlet
If the power plug is not removed from the outlet, you risk receiving an
electric shock.
Whenever there is a threat of lightning, disconnect the power plug from the
outlet
If the power plug is not removed from the outlet, you risk causing malfunction
or receiving an electric shock.
Handle batteries carefully
If used improperly, batteries may explode or leak and cause damage or injury.
In the interest of safety, please read and observe the following precautions.
- Remove the batteries whenever the unit is to remain unused for an extended period of time.
- Never keep batteries together with metallic objects such as ballpoint pens, necklaces, hairpins, etc.
- Used batteries must be disposed of in compliance with whatever regulations for their safe disposal that may be observed in the region in which you live.
CAUTION
Take care not to get burned
Batteries may reach a high temperature; please be careful to avoid burning
yourself.
Handle leaking batteries carefully
-
Do not touch the liquid with your bare hands.
-
If any of the leaking fluid gets into your eyes, the loss of vision may result. Do not rub your eyes; use clean water to flush them thoroughly. Then, promptly see a doctor.
-
Burning of the skin or dermatitis may result if fluid has gotten onto your skin or clothing.
Use clean water to flush affected areas thoroughly; then, promptly see a doctor. -
Using a soft cloth, carefully wipe any remaining fluid from the inside of the battery compartment. Then, install new batteries.
IMPORTANT NOTES
Placement
-
This unit may interfere with radio and television reception. Do not use this unit in the vicinity of such receivers.
-
When moved from one location to another where the temperature and/or humidity is very difi erent, water droplets (condensation) may form inside the unit. Damage or
malfunction may result if you attempt to use the unit in this condition. Therefore, before using the unit, you must allow it to stand for several hours, until the condensation has completely evaporated. -
Do not place containers or anything else containing liquid on top of this unit. Also, whenever any liquid has been spilled on the surface of this unit, be sure to promptly wipe it away using a soft, dry cloth.
Maintenance
- Never use benzine, thinners, alcohol or solvents of any kind, to avoid the possibility of discoloration and/or deformation.
Additional Precautions
-
When disconnecting all cables, grasp the connector itself—never pull on the cable.
This way you will avoid causing shorts, or damage to the cable’s internal elements. -
When disposing of the packing carton or cushioning material in which this unit was packed, you must observe the waste disposal regulations that apply to your locality.
Intellectual Property Right
- Roland is an either registered trademark or trademark of Roland Corporation in the United States and/or other countries.
- Company names and product names appearing in this document are registered trademarks or trademarks of their respective owners.
FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit difierent from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
This equipment requires shielded interface cables in order to meet FCC class B
limit.
Any unauthorized changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
For Canada
CAN ICES-003 (B)/NMB-003 (B)
For EU Countries
Manufacturer: Roland Corporation
2036-1 Nakagawa, Hosoe-cho, Kita-ku, Hamamatsu, Shizuoka 431-1304, JAPAN
Importer: Roland Corporation
ENA 23 Zone 1 nr. 1620 Klaus-Michael Kuehnelaan 13, 2440 Geel, BELGIUM
For the U.K.
Manufacturer: Roland Corporation
2036-1 Nakagawa, Hosoe-cho, Kita-ku, Hamamatsu, Shizuoka 431-1304, JAPAN
Importer: Roland Europe Group Limited
Hive 2, 1530 Arlington Business Park, Theale, Reading, Berkshire. RG7 4SA
United Kingdom
SUPPLIER’S DECLARATION OF CONFORMITY
Compliance Information Statement
Model Name: BTY-NIMH/A
Type of Equipment: Rechargeable Battery Pack
Responsible Party: Roland Corporation U.S.
Address: 5100 S. Eastern Avenue Los Angeles, CA 90040-2938
Telephone: 323-890-3700
For EU Countries, For the U.K.
**** This symbol indicates that in EU countries, this product must be
collected separately from household waste, as defined in each region. Products
bearing this symbol must not be discarded together with household waste.
For EU Countries, For the U.K.
For information on AC adaptors that can be used with this product, refer to
the Roland website.
Roland Service Centers and Distributors
When you need repair service, access this URL and find your nearest
Roland Service Center or authorized Roland distributor in your country.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>